5. Replace the jet holder assembly if needed.
NOTE:
If replacing the jet holder assembly, first install the jet
holder assembly onto the burner support rail before attaching the
wire guard clip.
Gas Leaks
Carefully check for gas leaks at each gas component that was
removed, replaced, or otherwise serviced using a gas leak detector or
bubble test.
4.2.3 Manifold Removal and Replacement
Although rangetop components can be accessed and replaced
without removing the manifold, this procedure is provided if the
manifold needs to be replaced due to a gas leak in the manifold, or if
the threading on the manifold is bad due to removing the regulator.
1. Follow all safety precautions and steps in the
2. Remove the two knobs connected to the manifold support
brackets on the back of the control panel (see Figure 24).
3. Remove all gas tubes connecting the valves (both standard valves
and solenoid valves) to their respective jet holder assemblies.
Figure 24: Two Knobs Connected to Manifold Support Brackets
4. Remove the burner support rail (with jet holder assemblies
attached) by following the steps in the
Burner Support Rail Removal and Replacement
5. Remove the regulator from the manifold
page
.
6. Remove the microswitch and standard valve attached to the
right-most knob (see Figure 24). See
on page
7. Remove the solenoid valve, XLO valve and potentiometer
attached to the left-side knob depicted in Figure 24. See
on page