PAGE 6
Fig. 6
I WIRING TO THE REMOTE VENTILA-
TOR:
a) Run five wires #12 AWG MIN. (black white, blue, red,
and green) in 1/2" conduit from the remote ventilator
to the J-Box located in the hood assembly. See Fig,
6.
b) Strip approximately 3/8" at the end of the above
wires. Use spring type wire nuts supplied to connect
blue, red, black, white and green wires to corre-
sponding color wires located inside the J-box. (Note:
Follow the wiring diagram supplied with ventilator.)
(Lost or missing wire nuts should only be replaced
with: Spring type wire nuts, rated for a minimum of
(2) # 18ga wires and maximum of (4) #14ga wires,
UL & CSA rated to 600V and 302 deg. F./150 deg. C).
II WIRING TO THE POWER SUPPLY:
a) Power supply required for this model is 120V., 19
Amps., 60 Hz. Using flex conduit , run three (3) #12
AWG. maximum (black, white, and green) from the
service panel to the J-Box located in the hood. See
Fig. 6.
b) Strip approximately 3/8" at the end of these three
wires. Use the provided wire nuts to connect the
black, white, and green wires to the corresponding
color wires located inside the J-box. (
Note:
follow
the wiring diagram.)
c) When using the power supply in a damp location or
outdoors, always install it in a GFCI protected branch
circuit.
STEP 4 -
ELECTRICAL CONNECTION:
SAFETY WARNING:
Turn off power circuit at the service
entrance and lock out panel before
wiring this unit.
Fig.7
Power Supply Wires
Conduit
To Remote Ventilator
23"
8"
STEP 5 -
INSTALL GREASE TROUGHS
AND FILTERS
See Care and Use Manual for instructions.