background image

©2015 Thermaco, Inc. All rights reserved  •  Patented/Patents Pending  •  Specifications subject to change without notice

Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651

MNL-ISPS50000 5

50000 Series

VOICE 336-629-4651  FAX 336-626-5739

PO BOX 2548, ASHEBORO, NC 27203

646 GREENSBORO STREET



DESTROY THIS DRAWING, IT IS THE SOLE PROPERTY OF THERMACO, INC. AND MUST BE RETURNED UPON REQUEST.

OF THIS DRAWING DOES CONSTITUTE AN IMPLIED AGREEMENT BETWEEN THERMACO, INC. AND THE HOLDER OF THIS DRAWING.  DO NOT

WRITTEN CONSENT FROM THERMACO, INC.  POSSESSION OF THIS DRAWING DOES NOT CONSTITUTE THE RIGHT TO MANUFACTURE.  POSSESSION

THIS DRAWING CONTAINS PROPRIETARY AND PATENTED MATERIAL.  THIS DRAWING MAY NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT

.XXX +/- 0.015

.XX +/- 0.03

Decimals

+/-1°

Angular

Tolerances

Dimensions are in inches

Unless otherwise specified

MATERIAL (UNLESS NOTED)

FINISH (UNLESS NOTED)

PART NO.

CHECKED

ENGINEERING

DRAWN

DATE

A

THIRD ANGLE PROJECTION

RELEASE DATE

REVISIONS

ZONE

REV

DESCRIPTION

DATE

APPROVED

SCALE

SHEET      OF

SIZE

REV. NO.

DWG NO.

Digital Control Operation (Default Modes)

Big Dipper

®

 IS System

Digital Control Operation

Timed Skimming Default

Through  the  “User  Interface”  three 

levels of skimming may be selected in 

the “default” mode. By selecting one of 

the skimming buttons – I, II, or III - the 

skimming  cycle    (see  table  below)  is 

activated.  The  LED  associated  with 

the  selected  button  is  illuminated 

continuously as an indicator of the 

selected  skim  cycle  and  as  a  “power 

on”  indicator.  If  the  skimming  level  is 

changed  during  an  active  skimming 

cycle, the next active skim cycle will be 

at the new setting (The LED associated 

with the newly selected level will change 

immediately).  If  the  skimming  cycle 

is  changed  between  active  skimming 

cycles the next skim cycle will be at the 

new level.

Motor Exercising

For all default mode skimming levels, the 

motor will be energized for 30 seconds 

every 9.5 hours. Only the motor will be 

energized (no heater operation) at these 

exercising times.

Heavy Setting:

Recommended for 

Heavy Grease Output 

(Steakhouses, Buffets, 

Heavy Grease 

producing sites***)

Start Button: Press 

to begin a cycle early 

or to test operation..

Light Setting: 

Recommended for 

Light Grease Output 

(Small Cafes, Coffee/

Ice Cream shops***)

Moderate Setting: 

Recommended for 

Moderate Grease Output 

(Quick and Full-Service 

restaurants***)

Start Button Operation

Any time the start button is depressed the “time between skims” the digital control goes to its maximum time and 

operation begins for the selected skim level. After this skimming cycle the normal time delay to the next skim cycle 

is used (skim cycle resets when the start button is depressed).

Heater Operation 

The heater operates under Thermistor control any time the skimmer motor is energized and anytime the liquid 

temperature drops to 40º F to prevent liquid from freezing. Contact Thermaco for programming alternative heater 

settings.

Default Modes - Normal Operation*

Button Selected

Skim Time

Delay Between Skims**

Light (I)

15 Minutes

76 Hours

Moderate (II)

30 Minutes

19 Hours

Heavy (III)

60 Minutes

19 Hours

*  For Extreme Conditions see next page.

** Delay between Skims is the time from the start of the 1st skim to the start of the next skim.

*** Only examples, actual mode needed will vary depending upon menu, warewashing procedures, etc.

Содержание Big Dipper 50000 Series

Страница 1: ...E OR PART WITHOUT WRITTEN CONSENT FROM THERMACO INC POSSESSION OF THIS DRAWING DOES NOT CONSTITUTE THE RIGHT TO MANUFACTURE POSSESSION OF THIS DRAWING DOES CONSTITUTE AN IMPLIED NONDISCLOSURE AGREEMEN...

Страница 2: ...SPS50000 2 50000 Series Table of Contents Table of Contents IS System Overview 3 IS System Maintenance 4 IS Digital Control Operation 5 IS System Troubleshooting 7 How To Reverse IS System Operation 8...

Страница 3: ...on container A digital control maintains the self cleaning operation activating the skimming wheel periodically based on the setting chosen Only the cleaned water exits the unit and flows into the fac...

Страница 4: ...blades are clipped in place properly B Press the Start button on the bottom of the user interface momentarily to ensure that the motor and skimming wheel are still operating correctly C Check the thi...

Страница 5: ...ge immediately If the skimming cycle is changed between active skimming cycles the next skim cycle will be at the new level Motor Exercising Foralldefaultmodeskimminglevels the motor will be energized...

Страница 6: ...the Heavy Mode III Button 3 The button III will blink temporarily indicating which operation level has been selected 4 Select desired mode at skim times frequencies listed below Extreme Modes Button...

Страница 7: ...uld be illuminated Ifnoneofthesettingbuttonsareilluminated the unit is not powered 2 Lift the sump cover and clean away any buildup that may be present on the wiper blades or collection trough Make su...

Страница 8: ...GREEMENT BETWEEN THERMACO INC AND THE HOLDER OF THIS DRAWING DO NOT DESTROY THIS DRAWING IT IS THE SOLE PROPERTY OF THERMACO INC AND MUST BE RETURNED UPON REQUEST MATERIAL UNLESS NOTED FINISH UNLESS N...

Страница 9: ...With Water Before Applying Power BigDippersystems equippedwithanelectric heating element MUST be filled with water before energizing the power to the system Failuretodosomaydamagetheelectricheating e...

Страница 10: ...EEMENT BETWEEN THERMACO INC AND THE HOLDER OF THIS DRAWING DO NOT DESTROY THIS DRAWING IT IS THE SOLE PROPERTY OF THERMACO INC AND MUST BE RETURNED UPON REQUEST MATERIAL UNLESS NOTED FINISH UNLESS NOT...

Страница 11: ...Control for W 200 IS VFCA 25 Vented Flow Control for W 250 IS VFCA 35 Vented Flow Control for W 350 IS VFCA 50 Vented Flow Control for W 500 IS 2 3 Installations where head height is greater than 6 f...

Страница 12: ...eck local plumbing code to determine if they are permitted by state or local plumbing code VFCA Vented Flow Control Installation Instructions IMPORTANT The flow control should be installed after the l...

Страница 13: ...t Socket Outlet NOT SUPPLIED Digital Control Big Dipper Electrical Requirements 4 5 Amps 115 VAC 50 60Hz 520 Watts For 230 VAC Units 2 3 Amps 230 VAC 50 60Hz 520 Watts Note Digital Control Supplied wi...

Страница 14: ...LESS NOTED FINISH UNLESS NOTED 646 GREENSBORO STREET PO BOX 2548 ASHEBORO NC 27203 VOICE 336 629 4651 FAX 336 626 5739 Decimals XX 03 XXX 015 Unless otherwise specified Dimensions are in inches Tolera...

Страница 15: ...RMACO INC AND THE HOLDER OF THIS DRAWING DO NOT DESTROY THIS DRAWING IT IS THE SOLE PROPERTY OF THERMACO INC AND MUST BE RETURNED UPON REQUEST MATERIAL UNLESS NOTED FINISH UNLESS NOTED 646 GREENSBORO...

Страница 16: ...ING DOES NOT CONSTITUTE THE RIGHT TO MANUFACTURE POSSESSION OF THIS DRAWING DOES CONSTITUTE AN IMPLIED NONDISCLOSURE AGREEMENT BETWEEN THERMACO INC AND THE HOLDER OF THIS DRAWING DO NOT DESTROY THIS D...

Страница 17: ...V NO DWG NO PART NO C SCALE RELEASE DATE SHEET OF ENGINEERING DRAWN DATE THIRD ANGLE PROJECTION Big Dipper IS System Replacement Parts SOLIDS STRAINER BASKET FOR MODEL USE PART W 200 IS SS THROUGH W 2...

Страница 18: ...aterials Thermaco shall not be respon sible for damage to products resulting from vault flooding sewer line back up pumping or lift station failure ambient water flow or other sources of water damage...

Отзывы: