TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
SOLUTION
Burner flame to large.
Incorrect pressure setting or
orifice.
Check pressure setting and orifice.
Burner flame soft and yellow
tipping.
Insufficient primary air.
Check air shutter setting.
Flame lifts off burner ports
Excessive primary air.
Check air shutter setting.
Flame lights back to orifice
Excessive primary air
Check air shutter setting.
Delayed ignition
1) Pilot flame too small.
2) Burner ports blocked.
3) Incorrect air shutter setting.
4) Incorrect pressure setting.
5) Pilot lighter tube dirty or
blocked.
1)
Check pilot flame length.
2)
Clean burner ports.
3)
Check air shutter setting.
4)
Check pressure setting.
5)
Clean tube.
Pilot burner will not ignite
1)Pilot blocked or dirty.
2)Pilot adjusting screw closed.
1)Clean pilot.
2)Open & adjust flame length.
HOW TO OBTAIN SERVICE
For warranty service, contact your local THERMA-TEK authorized service agency. Provide him or her
with the Model #, Serial #, date of installation, and a brief description of the problem. If you need assistance
locating the authorized service agency in your area, contact your local dealer. He or she will have a listing
of authorized dealers in your area, or on the web
www.therma-tek.com
We want you to remain a satisfied customer. If a problem comes up that cannot be resolved to your
satisfaction, please contact our customer service at:
714-968-7498
714-968-3529 (fax)
877-THERTEK (toll free)
Or e-mail us at
For Technical support call: 570-455-3000