Therma-tek TCTYG36 Скачать руководство пользователя страница 3

INSTALLATION  AND SAFETY GUIDELINES 

 

IMPORTANT 
 

Safe and  satisfactory  operation  of your  equipment  depends  on its  proper installation.  Installation  must 
conform  to local  codes, or in  the  absence of  local  codes with  the National  Fuel  Code ANSI Z223.1 (latest 
edition). 
All  THERMA-TEK  appliances  are shipped  with  a gas pressure  regulator  packed with  the  unit.   All  units  are 
adjusted,  tested,  and inspected  at the factory  prior  to shipment. 
After  uncrating,  immediately  check  the equipment  for visible  signs  of shipping  damage.   If  such  damage  has 
occurred,  do not refuse  shipment,  but  contact  the shipper  and file  appropriate  freight  claims. 
 

GENERAL 
 

 

Installation  of this  equipment  should  be made  by licensed  and authorized  personnel. 

 

A manual  gas shut-off  valve  must  be installed  in  the  gas supply  (service)  line  ahead of  the appliance 
and gas pressure  regulator  installed  in  the  gas stream  for  safety  and ease of  future  service. 

 

The  gas pressure  regulator  supplied  must  be installed  on the  appliance  prior  to connecting  the 
equipment  to the  gas line.   Failure  to install  a regulator  will  void  the  equipment  warranty  and result 
in  a potentially  hazardous  condition. 

 

The  appliance  and its  individual  shut  off  valve  must  be disconnected  from  the  gas supply  system 
during  any  pressure  testing  of that  system  in  excess  of ½ PSI. 

 

The  appliance  must  be isolated  from  the  gas supply  system  by closing  its  individual  shut  off  valve 
during  any  pressure  testing  of the  gas supply  piping  system  at test pressure  equal  to or less  than  ½ 
PSI. 

 

Please  contact  the  factory,  the  factory  representative,  or a local  authorized  service  company  to 
perform  maintenance  and  repairs. 

 

RATING PLATE 
 

Information  on this  plate  includes  the  model  and serial  number.   When  communicating  with  the factory 
about  a unit  or requesting  special  parts or information,  this  information  is required  for proper identification. 
Other information  on the  plate  is the  BTU/hr  input  of the  burners,  gas pressure  in  inches  WC, and whether 
the  unit  is  orificed  for  natural  or propane  gas. All  Teppan-Yaki’s  are 30,000 BUT's 
 

IMPORTANT: 

 The  appliance  must  be connected  only  to the  type of  gas identified  on the  rating  plate. 

 

GAS CONVERSION 
 

We recommend  that  the appliance  be ordered from  the factory  for the  type of  gas at the installation  site.   
When  gas  conversion  is necessary  contact  the factory  for a proper gas  conversion  kit. 

 
 

 

 
 
 

Содержание TCTYG36

Страница 1: ...TEPPAN YAKI OWNERS MANUAL AND INSTALLATION INSTRUCTIONS Made in U S A MODEL TCTYG36 shown...

Страница 2: ...NY OTHER APPLIANCE FOR YOUR SAFETY If you smell gas 1 Shut off gas to appliance 2 Extinguish any open flame 3 If odor continues immediately call your gas supplier Consult your local gas supplier for i...

Страница 3: ...he equipment warranty and result in a potentially hazardous condition The appliance and its individual shut off valve must be disconnected from the gas supply system during any pressure testing of tha...

Страница 4: ...adequate air supply Means must be provided for any commercial heavy duty cooking appliance to exhaust combustion wastes to the outside of the building Air movement should be checked during installati...

Страница 5: ...ly and blow them out with compressed air to clear any dirt particles threading chips or any other foreign matter before installing a service line Those particles will clog orifices when gas pressure i...

Страница 6: ...llation along with a dining table or counter The design of this counter and installation should only be performed by those experienced with this type of equipment Notice The griddle must be installed...

Страница 7: ...cated on the manifold is open Light the pilot and adjust flame to approximately 3 4 high SHUTDOWN Nightly shutdown Turn burner valves and thermostat to off position pilots will remain lit Complete shu...

Страница 8: ...nd food particles with a cloth Wash with hot soapy water and then rinse with vinegar and water solution Then rinse again with clean water Re oil with shortening or liquid frying compound Remove grease...

Страница 9: ...ressure setting 5 Clean tube Pilot burner will not ignite 1 Pilot blocked or dirty 2 Pilot adjusting screw closed 1 Clean pilot 2 Open adjust flame length HOW TO OBTAIN SERVICE For warranty service co...

Страница 10: ...s from installation b Rubber seals light bulbs andgaskets 90 days from installation c Cast iron parts 120days 7 This states the exclusive remedy against Therma Tek relatingto the product s whetherin c...

Отзывы: