background image

SANTA FE SERVICE PARTS LIST

 

 

To order contact your reseller or call 1-800-533-7533

ITEM 

PART NO. 

QTY. DESCRIPTION

4022254 

Accumulator

4021475 

Air Filter, Pleated, 2” x 16” x 20”

4021468 

Air Filter, Foam Element

4022037 

Blower w/ Capacitor

4021589 

Capillary Tubes, .050” ID x 28” long

4023474 

Compressor, Panasonic (2R12S3R126A-6A)

4022144 

Compressor Overload (TI # MRA98706-673; not shown)

4024666 

Compressor Run Capacitor for Panasonic, 35 MFD, 370V

4021396 

Condenser Coil

10 

4021409 

Cord & Wire Harness

11 

4021470 

Defrost Thermostat

 

4021648 

Defrost Thermostat Mounting Clip (item 11)

12 

4021395 

Evaporator Coil

13 

4025087 

Filter/Drier

14 

4021626 

Hose, Drain, .56”ID x 8’

15 

4021469 

Humidity Controller

16 

4021495 

Knob, Humidity Controller

17 

4025560 

Switch, SPDT, for Fan

18 

4021471 

Wheel, 2”, Plastic

19  

4021507 

Wiring Diagram (on cover; not shown)

20 

4021453 

Optional Ducting Kit (for inlet & outlet; not shown)

21 

4020623 

Optional Outlet Collar (for ducting outlet only; not shown)

22 

4022220 

Condensate Pump Kit (see page 10)

23 

4021586 

Ductable Inlet Kit (see page 12)

24 

4022561 

Silencer Kit (see page 13)

8

Santa Fe Installer’s & Owner’s Manual

9

Santa Fe Installer’s & Owner’s Manual

Содержание Santa-Fe

Страница 1: ...ation operating and safety instructions warranty information and all ancillary products n Read and save these instructions For small usage P O Box 8680 Madison WI 53708 TOLL FREE 1 800 533 7533 www th...

Страница 2: ...Size Unit Size w o duct collars 20 W x 17 D x 36 H Weight 110 lbs 2 Installation 2 1 Location The Santa Fe can be installed in a variety of locations to meet the owner s needs as listed below In all...

Страница 3: ...e in 10 lengths from building supply plumbing and hardware stores It will slide tightly inside the end of the drain hose If more than one length of pipe is required they can be joined with a short pie...

Страница 4: ...apillary tubing which cause the refrigerant pressure and temperature to drop It next enters the evaporator coil where it absorbs heat from the incoming air and evaporates The evaporator operates in a...

Страница 5: ...essor terminals C and R No continuity indicates an open run winding The compressor must be replaced Normal run winding resistance is 5 to 2 ohms 6 Compressor terminal C and overload terminal 1 No cont...

Страница 6: ...ystem with the quantity and refrigerant listed on the nameplate 8 Operate the system for a short period of time monitoring the suction pressure to determine that the suction filter is not becoming plu...

Страница 7: ...SANTA FE WIRING DIAGRAM 7 Santa Fe Installer s Owner s Manual Figure 2 Electrical Schematic of the Santa Fe Dehumidifier...

Страница 8: ...oil 10 4021409 1 Cord Wire Harness 11 4021470 1 Defrost Thermostat 4021648 1 Defrost Thermostat Mounting Clip item 11 12 4021395 1 Evaporator Coil 13 4025087 1 Filter Drier 14 4021626 1 Hose Drain 56...

Страница 9: ...oving 6 screws 4 Remove the 4 screws securing the wiring box to the inside of the blower end of the dehumidifier and pull the box away from the cabinet to allow access 5 Insert a romex connector or co...

Страница 10: ...are located near the bottom and on the same side of the unit as the drain hose STEP 5 Example of hose cut at a 45 angle The angle prevents the hose from sealing tight against the bottom of the pump re...

Страница 11: ...the inlet to the guides 4 Replace the filters in the unit Exhaust Collar Mounting Instructions 5 The six inch opening may be used as a fresh air inlet from outside 6 Remove the exhaust collar from the...

Страница 12: ...sher and 2 screws are not used on the Santa Fe Loosen these 2 screws enough to slide the silencer under the screw heads Insert 1 screw from the enclosed parts and tighten Santa Fe Muffler Kit Installe...

Страница 13: ...anta Fe Installer s Owner s Manual Foam filter with plastic grid up Pleated filter with air flow arrow pointed down AIR FLOW Top of Dehumidifier Instructions To prevent damaging the foam filter place...

Страница 14: ...and does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts o...

Страница 15: ...uced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Therma Stor LLC 2006 Therma Stor LLC All rights reserved PO Box 8680...