Evaporator coil frosted continuously, low 
dehumidifying capacity.
1. Defrost thermostat loose or defective.
2. Low refrigerant charge
3. Dirty air filter or air flow restricted.

8.3 Defrost Thermostat

The defrost thermostat is attached to the refrigerant suction
tube between the accumulator and compressor. It will 
automatically shut the compressor off if the low side 
refrigerant temperature drops due to excessive frost 
formation on the evaporator coil. The blower will continue 
to run, causing air to flow through the evaporator coil and
melt the ice. When the ice has melted, the evaporator 
temperature will rise and the thermostat will restart the 
compressor.

9 Service Parts List

PART NO.

DESCRIPTION

4021395 Coil, 

Evaporator

4021396

Coil, Condenser

4021470

Thermostat, Defrost Control

4021589

Tube, CU, CPLRY

4025087

Filter, Drier

4021469

Controller, Humidity, Face Mount

4025075

Compressor

4025076

Fan, Motorized Impeller

4025224

Capacitor, Impeller

4025244

Capacitor, Run

4025298

Overload, Compressor

4020554

Switch, Rocker, On-Off

10 Accessory/Replacement Parts

4021475

Filter, Air

4021626

Hose, Vinyl

4025264

Trap, Drain

4021495

Knob, Plastic, Black

4025463

Stand

4025466

Duct Collar Kit

To order, contact your reseller or 

call 1-800-533-7533.

11 Wiring Diagram

Figure 17:

Santa Fe HC Wiring Diagram

Figure 18:

Stand (P/N 4025463)

Figure 19:

Duct Collar Kit (P/N 4025466)

Содержание Santa Fe HC

Страница 1: ...tion and air filtration True Performance Off the shelf appliance grade dehumidifiers rate their dehumidification capacities at 80 F 60 relative humidity RH The performance of these devices drops signi...

Страница 2: ...ed to be installed indoors only 1 Intended Application for Santa Fe HC For the ideal installation draw air from the central part of the home and return it to isolated areas of the home like the bedroo...

Страница 3: ...section 5 for attaching duct collars ducting 4 1C In A Remote Area Duct Inlet Outlet Fig 6 It is often desirable especially in recreational rooms and finished areas to install the Santa Fe HC in an a...

Страница 4: ...wiring the control 4 2 Remote Humidity Controls All remote humidity controls should be mounted in a central area of the the space to be dehumidified where it can accurately sense the humidity of the...

Страница 5: ...duct ends must not excessively restrict air flow Isolated Areas Effective dehumidification may require that ducting be branched to isolated stagnant areas Use 6 diameter branch ducting to each of two...

Страница 6: ...ensed by giving up its heat to the air that is about to be discharged from the unit The refrigerant liquid then passes through a filter drier and capillary tubing which cause the refrigerant pressure...

Страница 7: ...has melted the evaporator temperature will rise and the thermostat will restart the compressor 9 Service Parts List PART NO DESCRIPTION 4021395 Coil Evaporator 4021396 Coil Condenser 4021470 Thermost...

Страница 8: ...plies to residential applications and does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repai...

Страница 9: ...Santa Fe HC Owners Manual 9...

Страница 10: ...produced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Therma Stor LLC 2004 Therma Stor LLC All rights reserved PO Box 8...

Отзывы: