4.5 Drainage and Trap

The Santa Fe HC requires a trap. Unit should be located in an
area where the unit’s condensate (water) may be easily routed
to a suitable drain. 

Thread the PVC barb fitting into the drain outlet on the front
of the unit. Push the hose onto the barb fitting past two
barbs minimum to ensure a good fit.

Route the drain hose through the trap as shown in Figure 12.
Position the trap on the hose approximately 12” away from
the unit.

5 Ducting

5.1 Optional Ducting Kit

An inlet shroud with a 10" round collar and an 10" round
exhaust collar are available from the factory that will allow
round ducting to be attached to the inlet and/or outlet of 
the Santa Fe HC. Refer to the optional equipment table 
in this document.

5.2 Ducting for Dehumidification

Ducting the Santa Fe HC requires consideration of the 
following points: 

Duct Sizing:

For total duct lengths up to 50 feet, use a

minimum 8" diameter round or equivalent rectangular. 
For longer lengths, use a minimum 10" diameter or 
equivalent. Grills or diffusers on the duct ends must 
not excessively restrict air flow.

Isolated Areas: 

Effective dehumidification may require

that ducting be branched to isolated, stagnant areas. Use
6" diameter branch ducting to each of two or three areas,
use 4" to each of four or more areas.

6 Operation

6.1 Humidity Control Adjustment

The humidity control is an adjustable switch that closes when
the relative humidity of the air in which it is located rises to
the dial set point. It opens when the RH drops 4 to 6% below
the set point.

Approximate Humidity Levels Per Setting

“Low”

35% to 45% Relative Humidity

“Normal” 45% to 55% Relative Humidity (Recommended)
“High”

55% to 65% Relative Humidity

The dehumidifier will run continuously until the relative
humidity (RH) is reduced to the humidity control dial setting.
The Santa Fe HC unit (and refrigerant based dehumidifiers in
general) will reduce a warm space's RH to a lower level than
that of a cool space. Therefore there is no benefit to set the
humidity control to excessively low levels in cool rooms. Doing
so will result in long periods of ineffective dehumidifier run time.

Quality humidity meters are available from the factory and
are recommended to accurately monitor humidity levels.
Refer to the options and accessories table in this document.

Figure 13:

Humidity control dial.

 

Figure 14:

Humidity control label on unit.

Содержание Santa Fe HC

Страница 1: ...tion and air filtration True Performance Off the shelf appliance grade dehumidifiers rate their dehumidification capacities at 80 F 60 relative humidity RH The performance of these devices drops signi...

Страница 2: ...ed to be installed indoors only 1 Intended Application for Santa Fe HC For the ideal installation draw air from the central part of the home and return it to isolated areas of the home like the bedroo...

Страница 3: ...section 5 for attaching duct collars ducting 4 1C In A Remote Area Duct Inlet Outlet Fig 6 It is often desirable especially in recreational rooms and finished areas to install the Santa Fe HC in an a...

Страница 4: ...wiring the control 4 2 Remote Humidity Controls All remote humidity controls should be mounted in a central area of the the space to be dehumidified where it can accurately sense the humidity of the...

Страница 5: ...duct ends must not excessively restrict air flow Isolated Areas Effective dehumidification may require that ducting be branched to isolated stagnant areas Use 6 diameter branch ducting to each of two...

Страница 6: ...ensed by giving up its heat to the air that is about to be discharged from the unit The refrigerant liquid then passes through a filter drier and capillary tubing which cause the refrigerant pressure...

Страница 7: ...has melted the evaporator temperature will rise and the thermostat will restart the compressor 9 Service Parts List PART NO DESCRIPTION 4021395 Coil Evaporator 4021396 Coil Condenser 4021470 Thermost...

Страница 8: ...plies to residential applications and does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repai...

Страница 9: ...Santa Fe HC Owners Manual 9...

Страница 10: ...produced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Therma Stor LLC 2004 Therma Stor LLC All rights reserved PO Box 8...

Отзывы: