Ultra-Aire Quiet Vent Installer’s & Owner’s Manual

Содержание Quiet-Vent Ventilation System

Страница 1: ...680 Madison WI 53708 TOLL FREE 1 800 533 7533 www thermastor com sales thermastor com TS 174B INSTALLER S OWNER S MANUAL HVAC INSTALLER PLEASE LEAVE MANUAL FOR HOMEOWNER P N 4019663 Serial No ________________________ Install Date ___________ Sold by ...

Страница 2: ... reduce the risk of fire electric shock or injury to persons observe the following A Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction B Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Foll...

Страница 3: ... from the Ultra Aire Quiet Vent see paragraph F In cold climates the unit should be located in a heated space to prevent condensation from forming inside the cabinet A basement or utility room is an ideal location If the Ultra Aire Quiet Vent and its ducting must be located in a unheated space in a cold climate they must be insulated to prevent condensation from forming in the system If the Ultra ...

Страница 4: ... stale air connect a six inch insulated flexible duct from the outlet of the Ultra Aire Quiet Vent to a dampered six inch wall cap If the length of the exhaust duct exceeds 50 ft an 8 duct should be used All the ducts must be insulated when they are located in non heated space in a cold climate Flexible duct can be spliced by threading the ends of the ducts into each other 3 turns To reduce leakag...

Страница 5: ...ired to control moisture and odors additional spades can be moved in If the home becomes too dry decrease the hours of low speed operation 3 2 Using Remote Timers Estimate the ventilation time required and set it on the timer Activate the timer whenever moisture or odors are generated in the room If timers are not available locally they may be ordered with the Ultra Aire Quiet Vent 3 2 Adjusting t...

Страница 6: ...the segments on the 7 day timer are moved to the center of the dial thus calling for low speed ventilation If the blower does not run with the segments in and the optional controls off check for voltage between timer terminal 5 and ground If terminal 5 does not have voltage the timer is defective If terminal 5 has voltage and relay terminal 5 does not have voltage the relay is defective If relay t...

Страница 7: ...y the period of time if any that the Ultra Aire Quiet Vent is out of service while awaiting covered warranty service UPON THE EXPIRATION OF THE WRITTEN WARRANTY APPLICABLE TO THE Ultra Aire Quiet Vent VENTILATING SYSTEM OR ANY PART THEREOF ALL OTHER WARRANTIES IMPLIED BY LAW INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SHALL ALSO EXPIRE ALL WARRANTIES MADE BY THERMA STOR LLC ARE ...

Страница 8: ...any form or by any means electronic or mechanical for any purpose without the express written permission of Therma Stor LLC 2008 Therma Stor LLC All rights reserved PO Box 8680 Madison WI 53708 Phone 608 222 5301 Fax 608 222 1447 Web www thermastor com Email sales thermastor com Ultra Aire Quiet Vent Installer s Owner s Manual ...