background image

quest

Asset Protection and IAQ Solutions

quest

1-800-533-7533 

Quest 

DRY 

150                 Installation, Operation and Maintenance Instructions

  

www.thermastor.com

[email protected]

Quest 

DRY 

150                   Installation, Operation and Maintenance Instructions

  

Quest 

DRY

 150 Dehumidifier Limited Warranty 

WARRANTOR:

 

Therma-Stor LLC 
PO Box 8680, Madison, WI 53708 
Telephone: 1-800-533-7533

WHO IS COVERED: 

This warranty extends only to the original end-user of the Quest 

DRY

 150 dehumidifier, 

and may not be assigned or transferred.

FIRST YEAR WARRANTY: Therma-Stor LLC  warrants that, for one (1) year the Quest 

DRY

 150 dehumidifier 

will operate free from any defects in materials and workmanship, or Therma-Stor LLC will, at its option, 
repair or replace the defective part(s), free of any charge.

SECOND THROUGH FIFTH YEAR WARRANTY:

 Therma-Stor LLC  further warrants that for a period of five 

(5) years, the condenser, evaporator, and compressor of the Quest 

DRY

 150 dehumidifier will operate free of 

any defects in material or workmanship, or Therma-Stor LLC, at its option, will repair or replace the defective 
part(s), provided that all labor and transportation charges for the part(s) shall be borne by the end-user.

END-USER RESPONSIBILITIES:

 Warranty service must be performed by a Servicer authorized by Therma-

Stor LLC. If the end-user is unable to locate or obtain warranty service from an authorized Servicer, he 
should call Therma-Stor LLC  at the above number and ask for the Therma-Stor LLC Service Department, 
which will then arrange for covered warranty service. Warranty service will be performed during normal 
working hours.

The End-user must present proof of purchase (lease) upon request, by use of the warranty card or other 
reasonable and reliable means. The end-user is responsible for normal care. This warranty only applies to 
residential applications and does not cover any defect, malfunction, etc. resulting from misuse, abuse, lack 
of normal care, corrosion, freezing, tampering, modification, unauthorized or improper repair or installation, 
accident, acts of nature or any other cause beyond Therma-Stor LLC's reasonable control.

LIMITATIONS AND EXCLUSIONS: 

If any Quest 

DRY

 150 Dehumidifier part is repaired or replaced, the 

new part shall be warranted for only the remainder of the original warranty period applicable thereto (but all 
warranty periods will be extended by the period of time, if any, that the Quest 

DRY

 150 Dehumidifier is out 

of service while awaiting covered warranty service).

UPON THE EXPIRATION OF THE WRITTEN WARRANTY APPLICABLE TO THE QUEST 

DRY 

150 

DEHUMIDIFIER OR ANY PART THEREOF, ALL OTHER WARRANTIES IMPLIED BY LAW, INCLUDING 
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL ALSO EXPIRE.  ALL 
WARRANTIES MADE BY THERMA-STOR LLC  ARE SET FORTH HEREIN, AND NO CLAIM MAY BE MADE 
AGAINST THERMA-STOR LLC BASED ON ANY ORAL WARRANTY. IN NO EVENT SHALL THERMA-STOR 
LLC, IN CONNECTION WITH THE SALE, INSTALLATION, USE, REPAIR OR REPLACEMENT OF ANY 
QUEST 

DRY 

150 DEHUMIDIFIER OR PART THEREOF BE LIABLE UNDER ANY LEGAL THEORY FOR ANY 

SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION WATER 
DAMAGE (THE END-USER SHOULD TAKE PRECAUTIONS AGAINST SAME), LOST PROFITS, DELAY, OR 
LOSS OF USE OR DAMAGE TO ANY REAL OR PERSONAL PROPERTY.

Some states do not allow limitations on how long an implied warranty lasts, and some do not allow the 
exclusion or limitation of incidental or consequential damages, so one or both of these limitation may not 
apply to you.

LEGAL RIGHTS:

 This warranty gives you specific legal rights, and you may also have other rights which vary 

from state to state.

Содержание Quest DRY 150

Страница 1: ...and Maintenance Instructions P O Box 8680 Phone 608 222 5301 Madison WI 53708 Toll Free 1 800 533 7533 www thermastor com sales thermastor com Read and Save These Instructions Specifications subject...

Страница 2: ...ilation Schedule 11 4 4C Automatic or Manual Mode 11 Controls Wiring Diagram 12 5 DEH 3000 Digital Control Installation Instructions 13 5 1 Specifications 13 5 2 Installation 13 5 2A Install Instructi...

Страница 3: ...INDOORS IN A SPACE THAT IS PROTECTED FROM RAIN AND FLOODING Install the unit with space to access the back or side panels for maintenance and service DO NOT INSTALL UNIT WITH THE SERVICE PANELS INACCE...

Страница 4: ...lbs 3 Installation 3 1 Location The Quest DRY 150 can be installed in a variety of locations to meet the owner s needs as listed below In all cases keep the following cautions in mind It is designed t...

Страница 5: ...Y 150 OR DAMAGE TO THE TRANSFORMER WILL RESULT The Quest DRY 150 plugs into a common grounded outlet It draws around 6 9 Amps under normal operating conditions If used in a wet area pool spa room or b...

Страница 6: ...n Sections 3 4A 3 4G requires consideration of the following points Duct Sizing For total duct lengths up to 25 use a minimum 10 diameter round or equivalent rectangular For longer lengths use a minim...

Страница 7: ...lspace with an Existing Forced Air HVAC System It is recommended that a new separate return duct be installed for the Quest DRY 150 from a central area of the structure If this is not possible and if...

Страница 8: ...o be adjusted and prevents flow of air between the ducting systems Contact the factory for assistance if necessary 3 4G Installation in a Structure with No Existing Forced Air HVAC System When install...

Страница 9: ...ntrols the humidity of the space The humidity fan control panel contains an adjustable humidity control and a fan switch The panel has a cover that must remain open to the air within the living space...

Страница 10: ...e unit is used for air circulation and filtration to achieve maximum indoor air quality When the switch is ON air will be constantly filtered through the Quest DRY 150 and circulated throughout the st...

Страница 11: ...operates on a 24 hour clock military time Then press the m button to set the minutes past the hour to start the ventilation Now with the ventilation start time set press the I O button The word OFF sh...

Страница 12: ...from the unit to contact the red lead or the white lead from the unit or damage to the transformers will result Do not direct connect the white lead on the unit to the violet lead on the ventilation...

Страница 13: ...5 Tighten the screws to lock into position 6 Make the electrical connections to the terminals on the back panel as shown in the wiring diagram 7 Reassemble the front to the back panel Connect at the...

Страница 14: ...ing cooling system with dehumidifier operation The DEH 3000 features a relay that provides this ability The relay terminals labeled NC COM and NO operate according to the following chart Dehumidificat...

Страница 15: ...EHUMIDIFIER ACTIVATES WHEN THE AIR CONDITIONER IS RUNNING The common wire on the thermostat transformer black needs to be wired with the yellow wire from the dehumidifier The Yellow wire from the ther...

Страница 16: ...operation should be noted and ventilation damper if used should be closed 6 Verify ventilation damper operation if installed by disengaging from operation and engaging ventilating operation a Press an...

Страница 17: ...touch any buttons for 10 seconds the control will remember any changes made and return to home 5 3C On Off Setting Press the ON OFF button to turn the system on or off When the system is on the setpo...

Страница 18: ...at the humidity setpoint be set below 35 In order to dry the structure in the winter in a cold climate use the ventilation function of the system rather than the dehumidifier function Call the factory...

Страница 19: ...ed by ON TIME OFF TIME Refer to section 3 8 With the damper in the OPEN hold mode the damper will be open and the fan of the system will be operating in order to introduce fresh air into the space Use...

Страница 20: ...fresh air for 15 minutes then stop for 15 minutes This schedule of 15 minutes open 15 minutes closed will continue until the start time of the night schedule Press program enter again to go to the MO...

Страница 21: ...000 is programmed with the following defaults A space is provided to make note of user inputs Setting Default My Setting RH setpoint 50 __________ Ventilation Operation Closed __________ Fan Setting A...

Страница 22: ...roglass paper filter is available for the Quest DRY 150 This filter is rated as 90 95 efficient by the ASHRAE Dust Spot test method 52 76 The high efficiency pleated microglass paper filter should be...

Страница 23: ...onstant pressure and temperature across the entire coil from inlet to outlet The mixture of gas and liquid refrigerant enter the accumulator after leaving the evaporator coil The accumulator prevents...

Страница 24: ...eller fan relay 5 Defective impeller fan capacitor Impeller fan runs with fan switch ON Impeller fan does not run with ventilation timer activated 1 Defective ventilation timer 2 Time not correct on v...

Страница 25: ...e humidity control the compressor and impeller fan should run 8 If these tests work the problem is most likely in the field control wiring 7 4 Refrigerant Charging If the refrigerant charge is lost du...

Страница 26: ...d and must be replaced if continuity exists across its terminals If there is no needle movement with the meter set on the Rx100000 scale the capacitor is open and must be replaced 10 Reconnect the wir...

Страница 27: ...rchased If the Quest DRY 150 fails to operate as desired always check the settings of the controls to insure that they are correct Check that the controls are receiving 24Vac from the Quest DRY 150 Ch...

Страница 28: ...e damper motor or damage to the motor may result DO NOT force the blade of the damper by hand or damage to the damper motor may result The damper opens in one direction only The damper rotates very sl...

Страница 29: ...DRY 150 Installation Operation and Maintenance Instructions 29 www thermastor com sales questprotect com quest Asset Protection and IAQ Solutions quest FOR HVAC INSTALLER ONLY Electric Schematics FOR...

Страница 30: ...rotection and IAQ Solutions quest 1 800 533 7533 Quest DRY 150 Installation Operation and Maintenance Instructions 30 www thermastor com sales questprotect com Pictorial Electrical Diagrams FOR HVAC I...

Страница 31: ...D TO FILTER 8 4026472 1 TUBE DISCHARGE LINE 9 4026673 1 CONDENSOR 10 4026657 1 IMPELLER 11 4020924 1 RELAY BLOWER Item Part No Qty Description 12 4026687 1 45mFd CAPACITOR COMPRESSOR 13 4022487 1 TRAN...

Страница 32: ...9 4024125 1 Control Panel Assembly Ventilation Timer Humidity 30 4023660 1 Controller Humidity 31 4023672 1 Duct Damper 6 Diameter Electrically Actuated not shown 32 4024153 1 Cover for Items 28 29 no...

Страница 33: ...of the door in between the foam installation and the metal side Push down on the plastic door latch and swing door shut Once the door is shut release the door latch Collar Install Remove the 2 round...

Страница 34: ...other reasonable and reliable means The end user is responsible for normal care This warranty only applies to residential applications and does not cover any defect malfunction etc resulting from misu...

Отзывы: