ISSUE 2016 Rev 1 - Installation Manual 

ThermaQ 

 

Component Checklist 

 
General Installation Requirements 
 
The cylinder must be installed, commissioned and maintained by a competent installer holding their G3 unvented qualification, or being a 
member of a competent persons’ scheme. Once the unit is installed and commissioned, the user must be given an explanation of the operation 
of the cylinder, and be given this installation manual for future reference. 
 
Storage and Handling 
 
Care must be taken when handling the product. Given the weight of the unit, use more than 1 person for carrying where appropriate, and be 
sure to comply with safe working practices and lifting techniques to avoid injury or product damage. The cylinder must be stored upright in its 
original packaging, on a secure, level surface within a dry and frost-free environment. 
 
Siting the Unit 
 
The cylinder must be installed vertically on a flat base, capable of supporting the weight of the cylinder when full. The minimum 
recommended cupboard size is 650mm square. 
 
Nominal diameter of cylinder is 545mm. 
 
Areas that are subject to freezing should be avoided, however if the cylinder is outside of the heated area of the dwelling, such as a garage or 
outbuilding, ensure that frost protection is provided, and exposed pipework is insulated. Pipe lengths should be kept to a minimum to ensure 
minimal losses. For each metre an outlet is above the cylinder, the pressure will be reduced by 0.1 bar. 
 
It is important to have room for access to the valves and controls of the cylinder, in order that they can be serviced and maintained. The 
immersion heaters are 375mm in length, and space should be provided for future removal and replacement. 
 

Components(s) 

Direct  Indirect 

Solar Indirect 

Solar Twin 

Status 

Manual / Benchmark 

 

 

 

 

Loose 

ERP Label 

 

 

 

 

Loose 

Inlet Control Set 

 

 

 

 

Loose 

T & P Valve 

 

 

 

 

Fitted 

T & P Insulation Cover 

 

 

 

 

Loose 

Tundish 

 

 

 

 

Loose 

Immersion Heater(s) 

 

 

 

 

Fitted 

Control / Limit Stat 

 

 

 

 

Loose 

Single Limit Stat 

 

 

 

 

Loose 

Two Port Zone Valve 

 

 

 

 

Loose 

Solar Cable Grommet 

 

 

 

 

Loose 

Содержание AGDIR 0120

Страница 1: ...INSTALLATION MANUAL Issue 2016 Rev 1 Tested to BS EN 12897 2006 FOR MORE INFORMATION GO TO WWW THERMAQ CO UK Note By installing this product you agree to be bound by our Conditions of Sale found with...

Страница 2: ...roduct Specifications 3 General Installation and Commissioning 6 Service and Maintenance 9 Fault Finding 10 Benchmark Commissioning Checklist 15 Service Record 16 User Guide and Customer Service 17 Wi...

Страница 3: ...ISSUE 2016 Rev 1 Installation Manual 3 ThermaQ 2...

Страница 4: ...ponsibilities on both manufacturers and installers The purpose is to ensure that customers are provided with the correct equipment for their needs that it is installed commissioned and serviced in acc...

Страница 5: ...flat base capable of supporting the weight of the cylinder when full The minimum recommended cupboard size is 650mm square Nominal diameter of cylinder is 545mm Areas that are subject to freezing shou...

Страница 6: ...15MPa 1 5 bar working pressure and a 20 litres per minute flow rate Where mains inlet pressures Hot Outlet Non Return Valve Pump Temperature and Pressure Relief Valve Secondary Return Boiler Flow Boi...

Страница 7: ...n order to service the inlet control set Ensure the directional flow arrow on the inlet control set follows the required flow of water See schematic diagram A balanced cold supply is necessary if ther...

Страница 8: ...ld utilise the dual control high limit thermostat as described in Connection to a Boiler section For connection to the lower coil you will require a further two port valve and a single control thermos...

Страница 9: ...0 Specification for the design installation testing and maintenance of services supplying water for domestic use within buildings and their curtilages From the tundish pipework should terminate in a s...

Страница 10: ...of water is drained from the unit Open the hot tap closest to the unit and open the draining tap Note Water drained off may be hot SERVICE AND MAINTENANCE Servicing must be carried out annually and s...

Страница 11: ...ating tap outlet Insecure Pipework Increase the number of pipe clips External works to public mains Wait for works to be completed Reduced water flow Debris from water mains Strip cleanorreplace Inlet...

Страница 12: ...G Is water running from the Tundish Is the water being discharged hot Tundish YES NO Do you have pressure YES NO No fault See the flow chart for T P Valve See the flow chart for Inlet Control Group Ch...

Страница 13: ...erature Pressure Relief Valve YES NO Do you have pressure YES NO No fault with the T P No fault with the T P Replace T P if required Replace T P if required Check temperature setting of the cylinder s...

Страница 14: ...fails replace Dual Stat Test Stat continuity Reset Limit Stat Test Dual Stat continuity Is there power to the Element Thermostat Has the thermostat tripped Does the Immersion Heater work Find correct...

Страница 15: ...3 ThermaQ ENERGY CUT OUT FAULT FINDING Is the Cut Out Thermostat working Test Stat continuity Energy Cut Out Thermostat NO YES Reset Limit Stat No fault with the Thermostat If test fails replace Dual...

Страница 16: ...oming static cold water pressure at the inlet to the system Has a strainer been cleaned of installation debris if fitted Is the installation in a hard water area above 200ppm If yes has a water scale...

Страница 17: ...E 9 Date Engineer Name Company Name Telephone Number Signature SERVICE 8 Date Engineer Name Company Name Telephone Number Signature SERVICE 7 Date Engineer Name Company Name Telephone Number Signature...

Страница 18: ...ns where constant usage and reheating is required titanium immersion heaters must be fitted to comply with the warranty Exclusions 16 The effect of scale build up on the unit or its components 17 Any...

Страница 19: ...SUE 2016 Rev 1 Installation Manual 3 ThermaQ TYPICAL WIRING S PLAN 1 ZONE TYPICAL WIRING Y PLAN COLOUR CODES W WHITE G GREY BL BLUE G Y GREEN YELLOW L LIVE N NEUTRAL C COMMON SL SWITCHED LIVE E EARTH...

Страница 20: ...ISSUE 2016 Rev 1 Installation Manual 3 ThermaQ TYPICAL WIRING S PLAN 2 ZONE COLOUR CODES W WHITE G GREY BL BLUE G Y GREEN YELLOW L LIVE N NEUTRAL C COMMON SL SWITCHED LIVE E EARTH 19...

Страница 21: ...e goods to third parties in the normal course of business In this respect the Buyer shall act in the capacity of the Companies commission agent and the proceeds of such sale 6 6 1 shall be held in tru...

Страница 22: ...ISSUE 2016 Rev 1 Installation Manual 3 ThermaQ NOTES 21...

Отзывы: