ISSUE 2016 Rev 1 - Installation Manual 

ThermaQ 

 

PRODUCT SPECIFICATIONS 

 

Introduction 
 
Congratulations on your purchase, of this Unvented Hot Water Storage Cylinder. This UK manufactured product is made from Duplex 
stainless steel, which provides durability, resistance against corrosion, highly insulated with environmentally friendly foam, and then enclosed 
in a rust resistant white steel case. 
 
The cylinder is available in several formats: Direct and Indirect Single Coil models 120-300, Solar Single Coil and Solar Twin Coil models 
180-300. 
 
The cylinder is approved to comply with: 
 
The Building Regulations 2000 (England and Wales) Approved Document G. 
The Building Regulations (Scotland) 2000. 
United Kingdom Water Supply (Water Fittings) Regulations / Scottish Water Byelaws. 
 
This is through the high quality of its materials and construction, and is supplied complete with all necessary safety and control devices 
needed to connect directly with the cold water mains supply. 
 
 

 
Please ensure that you have understood this manual before starting the installation, and leave this guide with the user once the 
installation is complete. 
 

Benchmark 

 

The Benchmark scheme places responsibilities on both manufacturers and installers. The purpose is to ensure that customers are provided 
with the correct equipment for their needs, that it is installed, commissioned and serviced in accordance with the manufacturer’s instructions 
by competent persons and that it meets the requirements of the appropriate Building Regulations and relevant electrical qualifications. The 
Benchmark Checklist can be used to demonstrate compliance with Building Regulations and should be provided to the customer for future 
reference. 
 
Installers are required to carry out installation, commissioning and servicing work in accordance with the Benchmark Code of Practice which 
is available from the Heating and Hotwater Industry Council who manage and promote the scheme. 
 
Visit 

www.centralheating.co.uk

 for more information. 

 
The HWA Charter 
 
The Charter offers consumers quality assurance, product satisfaction and confidence in the manufacturer, that they will deliver a service 
beyond just supplying the product. 
 
The HWA Charter Code of Practice requires that all members adhere to the following: 
 

 

To supply fit for purpose products clearly and honestly described 

 

To supply products that meet or exceed appropriate standards, building and water regulations 

 

To provide pre and post sales technical support 

 

To provide clear and concise warranty details to customers. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание AGDIR 0120

Страница 1: ...INSTALLATION MANUAL Issue 2016 Rev 1 Tested to BS EN 12897 2006 FOR MORE INFORMATION GO TO WWW THERMAQ CO UK Note By installing this product you agree to be bound by our Conditions of Sale found with...

Страница 2: ...roduct Specifications 3 General Installation and Commissioning 6 Service and Maintenance 9 Fault Finding 10 Benchmark Commissioning Checklist 15 Service Record 16 User Guide and Customer Service 17 Wi...

Страница 3: ...ISSUE 2016 Rev 1 Installation Manual 3 ThermaQ 2...

Страница 4: ...ponsibilities on both manufacturers and installers The purpose is to ensure that customers are provided with the correct equipment for their needs that it is installed commissioned and serviced in acc...

Страница 5: ...flat base capable of supporting the weight of the cylinder when full The minimum recommended cupboard size is 650mm square Nominal diameter of cylinder is 545mm Areas that are subject to freezing shou...

Страница 6: ...15MPa 1 5 bar working pressure and a 20 litres per minute flow rate Where mains inlet pressures Hot Outlet Non Return Valve Pump Temperature and Pressure Relief Valve Secondary Return Boiler Flow Boi...

Страница 7: ...n order to service the inlet control set Ensure the directional flow arrow on the inlet control set follows the required flow of water See schematic diagram A balanced cold supply is necessary if ther...

Страница 8: ...ld utilise the dual control high limit thermostat as described in Connection to a Boiler section For connection to the lower coil you will require a further two port valve and a single control thermos...

Страница 9: ...0 Specification for the design installation testing and maintenance of services supplying water for domestic use within buildings and their curtilages From the tundish pipework should terminate in a s...

Страница 10: ...of water is drained from the unit Open the hot tap closest to the unit and open the draining tap Note Water drained off may be hot SERVICE AND MAINTENANCE Servicing must be carried out annually and s...

Страница 11: ...ating tap outlet Insecure Pipework Increase the number of pipe clips External works to public mains Wait for works to be completed Reduced water flow Debris from water mains Strip cleanorreplace Inlet...

Страница 12: ...G Is water running from the Tundish Is the water being discharged hot Tundish YES NO Do you have pressure YES NO No fault See the flow chart for T P Valve See the flow chart for Inlet Control Group Ch...

Страница 13: ...erature Pressure Relief Valve YES NO Do you have pressure YES NO No fault with the T P No fault with the T P Replace T P if required Replace T P if required Check temperature setting of the cylinder s...

Страница 14: ...fails replace Dual Stat Test Stat continuity Reset Limit Stat Test Dual Stat continuity Is there power to the Element Thermostat Has the thermostat tripped Does the Immersion Heater work Find correct...

Страница 15: ...3 ThermaQ ENERGY CUT OUT FAULT FINDING Is the Cut Out Thermostat working Test Stat continuity Energy Cut Out Thermostat NO YES Reset Limit Stat No fault with the Thermostat If test fails replace Dual...

Страница 16: ...oming static cold water pressure at the inlet to the system Has a strainer been cleaned of installation debris if fitted Is the installation in a hard water area above 200ppm If yes has a water scale...

Страница 17: ...E 9 Date Engineer Name Company Name Telephone Number Signature SERVICE 8 Date Engineer Name Company Name Telephone Number Signature SERVICE 7 Date Engineer Name Company Name Telephone Number Signature...

Страница 18: ...ns where constant usage and reheating is required titanium immersion heaters must be fitted to comply with the warranty Exclusions 16 The effect of scale build up on the unit or its components 17 Any...

Страница 19: ...SUE 2016 Rev 1 Installation Manual 3 ThermaQ TYPICAL WIRING S PLAN 1 ZONE TYPICAL WIRING Y PLAN COLOUR CODES W WHITE G GREY BL BLUE G Y GREEN YELLOW L LIVE N NEUTRAL C COMMON SL SWITCHED LIVE E EARTH...

Страница 20: ...ISSUE 2016 Rev 1 Installation Manual 3 ThermaQ TYPICAL WIRING S PLAN 2 ZONE COLOUR CODES W WHITE G GREY BL BLUE G Y GREEN YELLOW L LIVE N NEUTRAL C COMMON SL SWITCHED LIVE E EARTH 19...

Страница 21: ...e goods to third parties in the normal course of business In this respect the Buyer shall act in the capacity of the Companies commission agent and the proceeds of such sale 6 6 1 shall be held in tru...

Страница 22: ...ISSUE 2016 Rev 1 Installation Manual 3 ThermaQ NOTES 21...

Отзывы: