3. Assemble filter control valve into the filter tank.

a. Insert filter control valve (with o'ring in place) into the tank neck, taking care that the center pipe slips into the hole 

b. Place two plastic clamps around valve flange and tank flange and tighten just enough so that the valve may be 

d. Connect pump to control valve opening marked PUMP. After connections are made, tighten valve flange clamps with  

plumbing connections, suction lines to pump, waste, etc.

5. Make electrical connections to pump per pump instructions. 
6. To prevent water leakage, make sure all pipe connections are tight.

4. Make return to pool pipe connection to control valve opening marked RETURN and complete other necessary

MAIN DIMENSION

 in the bottom of the valve. 

rotated on tank for final positioning.

c. Carefully screw pressure gauge (with 

 in place) into tapped hole in valve body. Do not over-tighten.

o'ring

screwdriver, tapping around clamp with screwdriver handle to help seat valve flange clamp.  

REPLACEMENT PARTS OF FILTER

3-4

1. Make  sure the correct amount of filter media sand is located in the tank and  all connections have been connected and secured.

2. Depress control valve handle and rotate to BACKWASH position.   (To prevent damage to control valve seal, always depress handle 

before turning.)

3. Prime and start pump according to pump instructions (be sure all suction and return lines are open), allowing the filter tank to fill with 

water.  Once  water  is  flowing  out  of  the  waste  line,  run  the  pump  for  at  least  1  minute. The  initial    back-washing  of  the  filter  is 

recommended to remove any impurities or fine sand particles in the sand media.

4. Turn pump off and set valve to RINSE position.  Start pump and operate until water in sight glass is clear, about 1/2 to 1 minute. Turn 

pump off and set valve to FILTER position and restart pump. The filter is now operating in the   normal filter mode, filtering dirt particles 

from the pool water.

5. Adjust pool suction and return valves to achieve desired flow.  Check system and filter for water leaks and tighten connections, bolts, nuts, 

as required.

6. Note the initial pressure gauge reading when the filter is clean. (It will vary from pool to pool depending upon the pump and general piping 

system.)  As the filter removes dirt and impurities from the pool water, the accumulation of dirt in the  filter will cause the pressure to rise 

and diminish the water flow.  When the pressure gauge reading is 1.5 bar,  higher than the initial "clean" pressure you noted, it is time to 

backwash the filter (see BACKWASH under filter and control valve functions).

NOTE:  During initial clean-up of the pool water it may be necessary to backwash frequently due to the unusually

INSTALL/START-UP OF FILTER

heavy initial dirt load in the water.

B

A

A

B

Model

High

Diameter

mm

mm

DIMENSION TABLE

950

THERACLEAR 255

635

inch

Valve Port 

Size

Sand

kg

145

2.0"

REPLACEMENT PARTS OF MULTIPORT VALVE 

1  

3

2

4

5

6

7

8

9

10

11

14

15

16

15

17

18

19

20

21

22

13

12

Key

 

No

.

Part

 

No.

Product

 

Description

 

1

88281506

MPV08

 

6

-

Way

 

2

.

0

Clamp

 

Type

 

Multiport

 

Valve

2

89280103

2.0"Union Set(3 Pieces)With O-Ring for MPV08

 

Valve

3

06011029

Oil

 

Pressure

 

Gauge

 

With

 

O

-

ring

 (

40psi

)

01111048

Connector

 

for

 

Pressure

 

Gauge

/

Stopper

4

89280104

Sight

 

glass

 

with

 

O

-

Ring

5

89010119

M6

*

50

 

Screws

 

With

 

Nut

01271010

Clamp

 

Lock

 

6

02011134

O

-

Ring

 

for

 

Filter

 

Neck

7

89010110

Filter

 

tank

8

89010118

Standpipe

 

with

 

hub

9

01111062

Filter

 

Base

10

01181052

Fastener

 

for

 

Filter

 

Base

11

01172010

Laterals

 (

185mm

12

01172007

Laterals

 

bracket

 

13

89012516

Laterals

 (

115mm

)

Key No.

Part

 

No.

Product

 

Description

 

1

01013003

Handle

(

Big

)

2

03018008

Pin

 

for

 

Handle

3

01181027

Washer

 

for

 

Handle

4

01181028

Defend

 

Lock

5

01020009

2

.

0

Lid

6

01181002

Washer

 

for

 

Handle

7

02011022

O

-

Ring

 

for

 

2

.

0

Valve

 

Rotor

8

03014014

Spring

9

01020002

2

.

0

Valve

 

Rotor

 

with

 

O

-

Ring

10

02010003

O

-

Ring

 

for

 

Lid

11

01020010

2

.

0

Body

12

01111048

Connector

 

for

 

pressure

 

gauge

/

stopper

13

01111017

O

-

Ring

 

for

 

Drain

 

Plug

02020014

Drain

 

Plug

14

06011029

Oil

 

Pressure Gauge With O-Ring(40psi)

06021013

Plastic Pressure Gauge With O-Ring(40psi)

15

02020016

1

.

5

"

Union

 

Nut

(

Black

)

16

01013031

2

.

0

"

Connector

 (

black

)

17

01171154

2

.

0

"

Union

 (

A

/

E

)

18

01013032

2

.

0

"

Union

 

Nut

(

Black

)

19

02011008

O

-

Ring

 

for

 

Sight

 

Glass

01041004

Sight

 

Glass

20

02011005

O

-

Ring

 

for

 

Diffuser

21

01100001

2

.

0

Diffuser

22

02011134

O

-

Ring

105

Glass 
Media

kg

Theraclear

 

Glass

 

Filter

 

Media

 re

c

omm

e

nded rate: 

 

5

 

bags

 

x

 

Fine

 

Grade

 

2

 

bags

 

x

 

Course

 

Grade

 

(

added

 

to

 

tank

 

first

Отзывы: