When installing the exhaust vent into an existing
chimney (see Appendix D), a clean out tee must be
installed behind the heater before going up into the
chimney. This is necessary in order to remove the
fly ash accumulation.
7.
Exit termination (distance to openings):
a.
3 feet minimum above any forced air inlet
located within 10 feet.
b.
4 feet minimum below and horizontally or 1
foot minimum above any door, window, or
gravity air inlet into any building.
c.
2 feet minimum to an adjacent building and
7 feet minimum above grade when located
adjacent to public walkways.
8.
The pellet heater must be operated with a power
source and will not operate using natural draft.
If there is a power failure the heater will shut
down. If the 12-volt back-up system is installed,
the heater will automatically switch to the 12-
volt power.
Route the power supply cord so it does not touch
any of the exterior components of the heater.
a.
When exiting through the wall with your
Type "L" pellet vent pipe, you may go
straight out through a wall thimble. You
must connect a pellet vent tee at this point
and extend the vent pipe at least 5 feet
vertically outside to provide good draft and
allow the gases to exit. The tee must have a
clean out cap for inspection and regular
cleaning (see Figure 6). Whenever the pipe
run in any installation is 10 feet or more, the
use of 4-inch Type "L" vent pipe is required.
Horizontal runs must be limited to 2 feet. A
wall band is required for every 4 feet
minimum on a vertical run at an exterior wall.
5 FT MINIMUM RISE. IF
GREATER THAN 10 FT
USE 4” TYPE “L”
PELLET VENT PIPE
Содержание PARLOUR 3000
Страница 4: ...PARLOUR PELLET 3000 PELLET HEATER 4 of 31 LABORATORY LISTING LABEL...
Страница 20: ...PARLOUR PELLET 3000 PELLET HEATER 20 FIGURE 15 REPLACEMENT PARTS LIST 16...
Страница 22: ...PARLOUR PELLET 3000 PELLET HEATER 22 FIGURE 18 ELECTRICAL SCHEMATIC WIRING DIAGRAM 250 VAC 250 VAC...
Страница 25: ...PARLOUR PELLET 3000 PELLET HEATER 25 APPENDIX B E I FIREPOT ASSEMBLY...
Страница 26: ...PARLOUR PELLET 3000 PELLET HEATER 26 APPENDIX B OUTSIDE AIR HOOK UP...
Страница 29: ...PARLOUR PELLET 3000 PELLET HEATER 29 APPENDIX E REPLACEMENT OF IGNITER...
Страница 31: ...PARLOUR PELLET 3000 PELLET HEATER Thelin Hearth Products Inc 63 Laxalt Dr Carson City NV 89706 www thelinco com...