ECHO PELLET E.I. II
PELLET HEATER
7
FIGURE 1 - OVERALL DIMENSIONS
FIGURE 2
CAUTION: HOT WHILE IN OPERATION.
KEEP
CHILDREN,
CLOTHING,
AND
FURNITURE
AWAY.
CONTACT
MAY
CAUSE SKIN BURNS.
CLEARANCES
CHECK WITH LOCAL BUILDING OFFICIALS
FOR SPECIFIC CODE REQUIREMENTS. A
LISTED, TYPE "L" PELLET VENT PIPE IS
MANDATORY ON ALL INSTALLATIONS.
Clearance to Combustibles
Unit to Sidewall..................................... 5" (125 mm)
Unit to Backwall.................................... 3" ( 75 mm)
Unit to Diagonal Wall .........................3.5" (87.5 mm)
MOBILE OR MODULAR HOME
Mobile home installation should be in accordance
with the Manufactured Home and Safety Standard
(HUD), CFR 3280, Part 24.
WARNING: Outside combustion air is mandatory
in mobile or modular installations. An outside air
inlet MUST be provided for combustion and
ventilation air. The air inlet must remain
unrestricted while unit is in use. Outside air
connection is made at the air intake located on the
rear of the stove (see Figure 2). The Outside Air Kit
is mandatory for mobile and modular home
installations. The kit contains 2" flex tubing (part
#43000-270). Outside air kit includes flex tube,
hose clamp, and rodent screen/cap.
Do not hook up
unit without this kit
. Secure stove to the floor
utilizing the holes provided on the bottom of the
legs. Unit must be electrically grounded to steel
frame of mobile home.
WARNING: THE STRUCTURAL INTEGRITY
OF THE MOBILE HOME FLOOR, WALLS,
AND
CEILING/ROOF
MUST
BE
MAINTAINED. DO NOT INSTALL
IN
SLEEPING ROOM.
Use only listed Type "L" pellet vent components for
installation. Failure to use listed pellet vent pipe
will void your warranty. See pipe manufacturer
instructions for installation instructions.
Outside
Air Intake
Содержание ECHO-COMSTOCK PELLET E.I. II
Страница 4: ...ECHO PELLET E I II PELLET HEATER 4 LABORATORY LISTING LABEL...
Страница 9: ...ECHO PELLET E I II PELLET HEATER 9 FIGURE 4...
Страница 10: ...ECHO PELLET E I II PELLET HEATER 10 FIGURE 5...
Страница 11: ...ECHO PELLET E I II PELLET HEATER 11 FIGURE 6...
Страница 14: ...ECHO PELLET E I II PELLET HEATER 14 FIGURE 8...
Страница 22: ...ECHO PELLET E I II PELLET HEATER 22 FIGURE 13 REPLACEMENT PARTS LIST...
Страница 24: ...ECHO PELLET E I II PELLET HEATER 24 FIGURE 15 ELECTRICAL SCHEMATIC WIRING DIAGRAM 250 VAC 250 VAC...
Страница 27: ...ECHO PELLET E I II PELLET HEATER 27 APPENDIX B E I FIREPOT ASSEMBLY...
Страница 29: ...ECHO PELLET E I II PELLET HEATER 29 APPENDIX D IGNITER REMOVAL...
Страница 31: ...ECHO PELLET E I II PELLET HEATER 775 241 2586...