3.7.4 UPS
“UPS”
can set up UPS (
U
ninterruptible
P
ower
S
upply).
Figure 3.7.4.1
Currently, the system only supports and communicates with smart-UPS of APC
(American Power Conversion Corp.) UPS. Please review the details from the
website:
http://www.apc.com/
.
First, connect the system and APC UPS via RS-232 for communication. Then set
up the shutdown values when power is failed. UPS in other companies can work
well, but they have no such communication feature.
UPS Type
Select UPS Type. Choose Smart-UPS for APC, None
for other vendors or no UPS.
Shutdown
Battery Level
(%)
When below the setting level, system will shutdown.
Setting level to
“0”
will disable UPS.
Shutdown
Delay (s)
If power failure occurred, and system can not return to
value setting status, the system will shutdown. Setting
delay to
“0”
will disable the function.
Shutdown
UPS
Select ON, when power is gone, UPS will shutdown by
itself after the system shutdown successfully. After
power comes back, UPS will start working and notify
system to boot up. OFF will not.
Status
The status of UPS.
“Detecting…”
“Running”
“Unable to detect UPS”
“Communication lost”
“UPS reboot in progress”