5 Function and Operation
A Lens Shield - function

The lens shield contains 13 segments each of which can be broken in half. Each 
segment can block 10º detection angle within the fi eld of view by pressing it onto 
the outer ring of the sensor head. (See Fig. 25). The segments only work on the 
outer 240º zone. The inner 3m radius zone is unaffected. 

•  How to use:

1. Take the outer ring off the sensor head. (See Fig. 24).
2. Decide on the detecting zone (or zones) that you want to be reduced or blocked.
3. Insert the lens shield segments into the slot of the outer ring as following 

illustration (See Fig. 25). Then put the outer ring back into position on the sensor 
head. The example shown will have blocked a 30ºdetection angle within the 
outer 240º zone.

4. By breaking the outer section of a segment or group of segments the range at 

that position in the outer zone will be reduced from 16m to 7m and not 3m.

B Walk Test

The MLB/WPRO500C will start working automatically approx. 3 minutes after the 
power is switched ON.
Set the TIME knob to “6 sec.”, the LUX knob to “   ” and the METER knob to 
“+” (Factory Presets). 
You can start the “Walk Test” in any ambient light level and the light will go on 
for about 6 seconds after each detection. While the light is ON and for 2 seconds 
afterwards the person carrying out the walk must remain stationary before 
continuing on the path shown in Fig. 25.

•  How to adjust your desired detecting area(s):

1.  Follow Fig. 25 and start the Walk Test across the detection zones to check that the 

light under control comes on when entering or leaving a zone. Repeat it and adjust 
the METER knob or sensor head until you are satisfi ed with the detection area.

2.  To eliminate unrequired detection zones you need to use the lens shield (see 5A 

Lens Shield - function).

Notes:
• 

When using the lens shield or adjusting the knobs, be careful not to damage the lens.

• 

Conditions below may cause reduction in sensitivity of the sensor.

a.  On very foggy nights, sensitivity may be less due to moisture on the lens.
b.  On very hot days, sensitivity may be less due to the temperature of the human 

body being close to the temperature of the surroundings.

c.  On very cold days little heat will be emitted from the body with heavy clothing 

and head covering. This may reduce the sensitivity of the sensor.

d.  Soap or polish may damage the sensor lens and can cause reduced sensitivity. 

Clean with a soft damp cloth only.

Fig. 24

Fig. 25

Outer Ring

Fig. 26

Walk Test

Start

Finish

Содержание Time Guard MLBPRO500C

Страница 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 500W C Class Halogen Floodlight with 240º PIR Control Model MLBPRO500C Black Model MLWPRO500C White ...

Страница 2: ...contact problems Plug in terminal block for quick and easy wire free connection and convenient replacement of the light bulb Adjustable lens giving a 240º outer zone from 3 to 16m and a 360º inner zone giving comprehensive coverage within a 3m radius circle Multi segmented lens shields included for blocking zones within a detection area Each segment blocking a detection angle of 10º Rotatable sens...

Страница 3: ...Off the Mains Power Supply Before Installation The MLB WPRO500C can be either wall mounted or corner mounted with an adapter included with the product See Fig 5 Fig 5 Wall Mount Fig 5a Corner Mount Fig 5b Corner Mounting Adapter See section B Fig 6 Fig 7 A Installation Procedure a Read the instruction manual before installing the MLB WPRO500C b Make sure the mains power supply has been disconnecte...

Страница 4: ...ures 3 Locate one of the bulb contacts onto one of the fitting contacts and push back the contact spring at the other end inserting the bulb contact into its fitting contact check that the bulb contacts at each end are properly located and that there is reasonable pressure on the bulb contacts See Fig 10 4 Tighten the floodlight cover screws firmly to ensure weatherproof rating e Make backplate holes ...

Страница 5: ...e horizontally rotated 60º to right or left As shown in Fig 20 b Adjustment of the floodlight You can adjust horizontally right or left 45º See Fig 21 c The Adjustment of LUX METER and TIME The MLB WPRO500C has three adjustable knobs LUX METER and TIME on the underside of the sensor head The LUX knob can be set to allow the MLB WPRO500C to operate at any light level between full daylight and almost...

Страница 6: ...any ambient light level and the light will go on for about 6 seconds after each detection While the light is ON and for 2 seconds afterwards the person carrying out the walk must remain stationary before continuing on the path shown in Fig 25 How to adjust your desired detecting area s 1 Follow Fig 25 and start the Walk Test across the detection zones to check that the light under control comes on...

Страница 7: ...here are any white or reflective surfaces in the detection area and adjust the sensor to a different direction or adjust the lens shield 2 The sensor is more sensitive in winter Please check again when the temperature gets back to normal Rain snow and storm can create big temperature changes that activate the sensor False triggering can be minimised by installing the sensor in a protected location ...

Страница 8: ...up to 200W can be connected Power Consumption Less than 1W Quiescent Detection Angle 10º 240º adjustable for the outer zone detecting range from 3 to 16m 360º for the inner zone detection range within a radius of approx 3m Light ON Time Adjustable from about 6 seconds to 12 minutes METER range restriction Adjustable 3 16m LUX Adjustable ambient light level control Adjustable Angle Sensor Head Left...

Страница 9: ...ISS 1 Timeguard Limited Victory Park 400 Edgware Road London NW2 6ND Sales Office 020 8452 1112 or email csc timeguard com For a product brochure please contact Zerofour June 2010 or email helpline timeguard com HELPLINE 020 8450 0515 ...

Отзывы: