Theben Time Guard MLBPRO500C Скачать руководство пользователя страница 3

3

4

3 PIR Coverage

The MLB/WPRO500C should be installed within the height range 2.0m to 2.5m. 
(See Fig. 2).
The unit has an adjustable lens with two detection zones.
•  The outer zone covers an angle of 240º to a distance of approx. 3m to 16m at an 

installation height of 2.3m. (See Fig. 3).

•  The inner zone covers an angle of 360º which allows detection immediately 

behind the MLB/WPRO500C. (See Fig.4).

•  Fig. 4 also shows the variation of sensitivity with angle of approach for a person 

moving within the detection area.

Fig. 2

Fig. 4

Fig. 3

Side View

2.3m

16m

240°

Min.

Min.

35°

45°

500mm

200mm

16m

16m

3m

7m

7m

4m

4m

3 4

7

3

0

Top View

Most 
Sensitivity

Least 
Sensitivity

4 Installation

Installation shouild only be carried out by a competent person.

Switch Off the Mains Power Supply Before Installation

The MLB/WPRO500C can be either wall mounted or corner mounted with an 
adapter included with the product. (See Fig. 5).

Fig. 5

Wall Mount 
Fig. 5a

Corner Mount 
Fig. 5b

Corner Mounting Adapter 
(See section B)

Fig. 6

Fig. 7

A Installation Procedure

a. Read the instruction manual before installing the MLB/WPRO500C.
b. Make sure the mains power supply has been disconnected.
c. Decide the best location to install the unit bearing in mind the most sensitive 

direction of movement shown in Fig. 4.

  Then ensure that the top of the fl oodlight is no closer than 200mm to the surface 

above it and it is no closer than 500mm to the surface at the side of it. 
(See Fig. 6).

  Also ensure that any surface directly illuminated by the fl oodlight is at least 1m 

away from the front glass. (See Fig. 8).

  Do not mount the unit base on a horizontal surface such as a soffi t, 

(See Fig. 7) or on an infl ammable surface such as wood or plastic. 

Содержание Time Guard MLBPRO500C

Страница 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 500W C Class Halogen Floodlight with 240º PIR Control Model MLBPRO500C Black Model MLWPRO500C White ...

Страница 2: ...contact problems Plug in terminal block for quick and easy wire free connection and convenient replacement of the light bulb Adjustable lens giving a 240º outer zone from 3 to 16m and a 360º inner zone giving comprehensive coverage within a 3m radius circle Multi segmented lens shields included for blocking zones within a detection area Each segment blocking a detection angle of 10º Rotatable sens...

Страница 3: ...Off the Mains Power Supply Before Installation The MLB WPRO500C can be either wall mounted or corner mounted with an adapter included with the product See Fig 5 Fig 5 Wall Mount Fig 5a Corner Mount Fig 5b Corner Mounting Adapter See section B Fig 6 Fig 7 A Installation Procedure a Read the instruction manual before installing the MLB WPRO500C b Make sure the mains power supply has been disconnecte...

Страница 4: ...ures 3 Locate one of the bulb contacts onto one of the fitting contacts and push back the contact spring at the other end inserting the bulb contact into its fitting contact check that the bulb contacts at each end are properly located and that there is reasonable pressure on the bulb contacts See Fig 10 4 Tighten the floodlight cover screws firmly to ensure weatherproof rating e Make backplate holes ...

Страница 5: ...e horizontally rotated 60º to right or left As shown in Fig 20 b Adjustment of the floodlight You can adjust horizontally right or left 45º See Fig 21 c The Adjustment of LUX METER and TIME The MLB WPRO500C has three adjustable knobs LUX METER and TIME on the underside of the sensor head The LUX knob can be set to allow the MLB WPRO500C to operate at any light level between full daylight and almost...

Страница 6: ...any ambient light level and the light will go on for about 6 seconds after each detection While the light is ON and for 2 seconds afterwards the person carrying out the walk must remain stationary before continuing on the path shown in Fig 25 How to adjust your desired detecting area s 1 Follow Fig 25 and start the Walk Test across the detection zones to check that the light under control comes on...

Страница 7: ...here are any white or reflective surfaces in the detection area and adjust the sensor to a different direction or adjust the lens shield 2 The sensor is more sensitive in winter Please check again when the temperature gets back to normal Rain snow and storm can create big temperature changes that activate the sensor False triggering can be minimised by installing the sensor in a protected location ...

Страница 8: ...up to 200W can be connected Power Consumption Less than 1W Quiescent Detection Angle 10º 240º adjustable for the outer zone detecting range from 3 to 16m 360º for the inner zone detection range within a radius of approx 3m Light ON Time Adjustable from about 6 seconds to 12 minutes METER range restriction Adjustable 3 16m LUX Adjustable ambient light level control Adjustable Angle Sensor Head Left...

Страница 9: ...ISS 1 Timeguard Limited Victory Park 400 Edgware Road London NW2 6ND Sales Office 020 8452 1112 or email csc timeguard com For a product brochure please contact Zerofour June 2010 or email helpline timeguard com HELPLINE 020 8450 0515 ...