Theben Time Guard MLBPRO500C Скачать руководство пользователя страница 4

5

6

Cautions in use:

•  If the fl oodlight glass is cracked, replace it immediately before further use. 
•  The surface of the fl oodlight cover and glass get extremely hot when the lamp 

has been on for some time. Do not touch and keep combustible materials away.

•  Additional lighting of up to three 500W class C fl oodlights or 1.5kW of other 

approved fi lament lighting may be connected. (See Fig 12).

Fig. 8

MLB/WPRO500C

Fig. 9

Fig. 10

Front Glass

Floodlight 
Cover Screws

Fitting 
Contact

Bulb Contact

1 m Min.

Fig. 11

Fig. 12b

Fig. 13

Fig. 14

Backplate

Backplate Connections

Wiring Diagram

ON/OFF 

switch

Up to an 
additional 
three 500W 
halogens or 
up to 200W 
of low energy 
lighting

Cable entry 
knock outs

Switch 
terminal

Fixing hole

L

1

 connections on up to four 

MLB/WPRO500C's can be 
connected together and then to 
additional lights if allowable, so 
that any of these units will bring 
all the lights ON if triggered. The 
total lamp load is limited to a 
single units capacity.

Override switch 

(if required)

N

N

N

L

L

L

1

L

1

L

d. Install bulb:

1. Remove the lamp cover screws retaining front glass frame (See Fig. 9) and swing 

the glass frame away from the fl oodlight cover.

2. Check that the bulb and fi tting contacts are all clean, ensuring that you 

hold the 

bulb with a clean dry cloth during this and subsequent procedures.

3. Locate one of the bulb contacts onto one of the fi tting contacts and push back 

the contact spring at the other end inserting the bulb contact into its fi tting 
contact. check that the bulb contacts at each end are properly located and that 
there is reasonable pressure on the bulb contacts. (See Fig. 10).

4. Tighten the fl oodlight cover screws fi rmly to ensure weatherproof rating.

e. Make backplate holes and cable up:

Decide which of the four 20mm dia. cable entry holes on the back plate you wish to 
use (there are 2 rear entry and 2 bottom entry).
if you wish to use additional lighting a second entry point will be required (a manual 
override switch can be accommodated by a single entry of 4 core cable). Firstly cut 
undersize holes as required in the blind grommets supplied. This way sealing against 
moisture infl ux is maintained. Then score around the outside edge of the circular 
groove marking the hole with a sharp knife and gently tap out the centre. Do the same 
to the second entry point if necessary and fi t the grommet(s) supplied and push the 
cable(s) in to give suffi cient length to make a connection for all the cable wires.

f. Fix backplate:

Fix the backplate onto the wall with the large pan head screws supplied using 
wall plugs if necessary (See Fig. 11) remembering the cable entry holes are on the 
bottom. connect cable wires as necessary. (See Fig. 12).

g.

 Insert the sensor light onto the backplate (See Fig. 13). Then fi x with the two 

small c/sk head screws supplied. (See Fig.14).

Fig. 12a

Содержание Time Guard MLBPRO500C

Страница 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 500W C Class Halogen Floodlight with 240º PIR Control Model MLBPRO500C Black Model MLWPRO500C White ...

Страница 2: ...contact problems Plug in terminal block for quick and easy wire free connection and convenient replacement of the light bulb Adjustable lens giving a 240º outer zone from 3 to 16m and a 360º inner zone giving comprehensive coverage within a 3m radius circle Multi segmented lens shields included for blocking zones within a detection area Each segment blocking a detection angle of 10º Rotatable sens...

Страница 3: ...Off the Mains Power Supply Before Installation The MLB WPRO500C can be either wall mounted or corner mounted with an adapter included with the product See Fig 5 Fig 5 Wall Mount Fig 5a Corner Mount Fig 5b Corner Mounting Adapter See section B Fig 6 Fig 7 A Installation Procedure a Read the instruction manual before installing the MLB WPRO500C b Make sure the mains power supply has been disconnecte...

Страница 4: ...ures 3 Locate one of the bulb contacts onto one of the fitting contacts and push back the contact spring at the other end inserting the bulb contact into its fitting contact check that the bulb contacts at each end are properly located and that there is reasonable pressure on the bulb contacts See Fig 10 4 Tighten the floodlight cover screws firmly to ensure weatherproof rating e Make backplate holes ...

Страница 5: ...e horizontally rotated 60º to right or left As shown in Fig 20 b Adjustment of the floodlight You can adjust horizontally right or left 45º See Fig 21 c The Adjustment of LUX METER and TIME The MLB WPRO500C has three adjustable knobs LUX METER and TIME on the underside of the sensor head The LUX knob can be set to allow the MLB WPRO500C to operate at any light level between full daylight and almost...

Страница 6: ...any ambient light level and the light will go on for about 6 seconds after each detection While the light is ON and for 2 seconds afterwards the person carrying out the walk must remain stationary before continuing on the path shown in Fig 25 How to adjust your desired detecting area s 1 Follow Fig 25 and start the Walk Test across the detection zones to check that the light under control comes on...

Страница 7: ...here are any white or reflective surfaces in the detection area and adjust the sensor to a different direction or adjust the lens shield 2 The sensor is more sensitive in winter Please check again when the temperature gets back to normal Rain snow and storm can create big temperature changes that activate the sensor False triggering can be minimised by installing the sensor in a protected location ...

Страница 8: ...up to 200W can be connected Power Consumption Less than 1W Quiescent Detection Angle 10º 240º adjustable for the outer zone detecting range from 3 to 16m 360º for the inner zone detection range within a radius of approx 3m Light ON Time Adjustable from about 6 seconds to 12 minutes METER range restriction Adjustable 3 16m LUX Adjustable ambient light level control Adjustable Angle Sensor Head Left...