82

14. Warranty declaration

Theben HTS presence detectors are manufactured and tested for quality with greatest of care 

and most modern technology. Theben HTS AG thus guarantees smooth function with correct use. 

Should a malfunction appear, Theben HTS AG guarantees within the scope of the General Terms 

and Conditions:

Please notice specifically:

 

that the warranty is valid for 24 months from date of manufacture. 

 

that the warranty becomes void if you or a third party makes modifications or repairs to the 

devices.

 

that, as long as the presence detector is connected to a software controlled system, the war-

ranty for this connection is only valid if the interface specifications are adhered to.

We are obligated to improve or replace as quickly as possible all damaged or unusable parts within 

the scope of delivery, proven insufficient materials, faulty construction or lacking models up to the 

end of the guarantee period. 
Dispatching
For cases covered by the guarantee, send the device, together with the shipping order and a short 

description of the problem to the responsible specialised dealer.
Industrial property rights
Concept, as well as hard and software of this device are copyrighted.

Содержание PlanoCentro 000-A-230V

Страница 1: ...i per l uso 114 Gebruikshandleiding 142 Bruksanvisning 170 Bruksanvisning 198 Käyttöohje 226 Betjeningsvejledning 254 DK D F GB E I NL S N FIN Presence detector Bedienungsanleitung 2 Notice d utilisation 30 Operating Manual 58 Manual de instrucciones 86 Istruzioni per l uso 114 Gebruikshandleiding 142 Bruksanvisning 170 Bruksanvisning 198 Käyttöohje 226 Betjeningsvejledning 254 DK D F GB E I NL S ...

Страница 2: ...Table of contents 1 Safety 59 2 Function and performance 60 3 Installation 62 4 Connection Operation mode 66 5 Start up 69 6 Parameters 71 7 Read out data 72 8 Test Mode 73 9 Control commands 75 10 Diagnostics 76 11 Troubleshooting 77 12 Technical data 78 13 Dimension drawings 81 14 Warranty declaration 82 ...

Страница 3: ...Observe country specific safety guidelines for working on electric installations The voltage supply must be disconnected before installation CAUTION The device is maintenance free The warranty terminates if the device is opened or entered with any kind of object 1 1 Designated use The presence detector is intended for indoor installation The presence detector is solely intended for the purpose con...

Страница 4: ...ignal the PlanoCentro 000 helps with the comfortable and energy efficient control of lighting HVAC and shading The area of preferred use includes large spaces such as offices and classrooms Detection range up to 100m2 moving and 64m2 seated persons at 3 5 m installation height Adjustable sensitivity The PlanoCentro 000 has an output for parallel connection Helpful functions are available for start...

Страница 5: ...nal cover 3 PlanoFix E installation frame 4 Strap 6 pieces 5 PlanoCover frame 6 Template for ceiling cut out 7 Assembly instruction Flush mounted installation 1 Presence detector with installation protection cover removable 2 PlanoFix U installation plate 3 PlanoCover frame 4 4 screws 5 Assembly instruction 1 1 2 2 3 3 4 4 7 5 5 6 ...

Страница 6: ...ctor requires a clear view of people in order to clearly detect people Offices mobile partition walls plants hanging lighting etc can hinder shadowing the pres ence detector Detection range installation height 3 0m install height seated persons moving persons 2 0 m 20 m2 4 5m x 4 5m 36 m2 6 0m x 6 0m 0 5m 2 5 m 36 m2 6 0m x 6 0m 64 m2 8 0m x 8 0m 0 5m 3 0 m 49 m2 7 0m x 7 0m 81 m2 9 0m x 9 0m 1 0m...

Страница 7: ...iling cut out A hinge is integrated into the top of the packaging 2 Cut out the drawn form according to the materials with suitable tools 100 x 100 mm 1mm 3 Insert 4 straps into the PlanoFix E 4 Insert the PlanoFix E into the ceiling cut out with the straps 5 By pulling on the straps and pushing against the PlanoFix E the PlanoFix E is snapped securely into the ceiling element 6 Cut the ends of th...

Страница 8: ...remove the excess 3 Fasten the PlanoCap 4 Make sure the locks on the PlanoFix E are open 5 Insert the presence detector into the PlanoFix E 6 Close the locks on the PlanoFix E 7 Remove installation protection 8 Attach the PlanoCover The technical data is to be followed during assembly and installation See page 78 and following ...

Страница 9: ...n The screws included are intended for installation in the flush mounted socked Suitable pan head screws are to be used for the installation of other materials Install presence detector with PlanoFix U 1 Connect wires see technical data page 78 2 Insert the presence detector into the flush mounted junction box check the wire progression 3 Screw the PlanoFix U metal plate tightly to the flush mount...

Страница 10: ...regardless of whether it is master or slave sends the presence signal via P terminal This enables a Master and Slaves to be connected together with a parallel signal See following chapter with parallel connecting variations The parallel signal is compatible with the compact range Parallel signal response Room monitoring Information about room monitoring is also transmitted with the parallel signal...

Страница 11: ... Master switches the lighting All other detectors are slaves Presence detection through all detectors together Light measurement only with master Setting parameters on the Master Detection sensitivity can also be set on the Slave Maximum of 10 detectors can be connected in parallel Use the same phase for all detectors Presence e g HVAC Master PlanoCentro 101 A 230V Slave PlanoCentro 000 A 230V ...

Страница 12: ... 4 4 Detector as staircase lightning timer Master switched direct lighting The staircase function On prevents switching off via push button Push button activates channelA light If necessary parallel switch ad ditional slaves via P terminal Set parameter value only with master N N L L A P P S1 H2 PlanoCentro 101 A 230V H1 N L Master N L 4 3 B3 B2 ELPA 1 N N L L A P P S1 H2 PlanoCentro 101 A 230V H1...

Страница 13: ... 5 1 Basic settings Parameter Value Detection sensitivity PIR 3 Reduction of detection sensitivity when monitoring 2 5 2 Activating the basic settings The basic settings can be activated as follows Activation Description SW2 3 sec The SW2 button can be pressed and held down for 3 seconds to revert back to the basic settings The presence detector restarts at this point SW2 SendoPro The basic settin...

Страница 14: ...operation mode If there is a problem LED blinks rapidly the light is switched on and does not switch off 1 Start up phase 30 seconds LED blinks in second intervals Parallel output is active Parameter adjustment is possible active after start up phase has run Test mode can be activated 2 Operation mode normal The detector is ready for operation LED off 3 Event of malfunction LED flashes rapidly The...

Страница 15: ...resence detector via infrared with the SendoPro The parameters can be read out before changes take place Changed parameters are immediately accepted and applied by the detector LED Description Flickering during 3 sec After pressing the send function on the management remote control the presence detector displays correct receiving by flickering for 3 sec lights up shortly The command parameter sent...

Страница 16: ... test presence 6 4 Reducing sensitivity with room monitoring In order to prevent false alarms the sensitivity is reduced in levels relative to the base detection sensitivity 7 Read out data By means of the SendoPro management remote control the diagnostic and statistical data can be read out Additional information can be found in the SendoPro operation manual Level Reduction 1 less 2 Standard 3 in...

Страница 17: ...ement remote control Activate Push button SW2 short button push 1x Test presence on with the SendoPro management remote control The test mode presence can always be activated Terminate With subsequent restart Repress SW2 ends operation mode and restarts the detector Command Test presence off with the SendoPro management remote control Power outage and thus power up The detector automatically resta...

Страница 18: ...nds are possible with the SendoPro management remote conrol Terminate test presence Activate basic settings Reset Change detection sensitivity Change reducing sensitivity with room monitoring The selected detection sensitivity 1 5 see page 72 is not changed with the test presence activa tion Sensitivity can be adjusted during the test The presence detector resets after test mode has terminated ...

Страница 19: ...ommands Control commands are available as follows Test presence See chapter 8 1 page 73 Restart The detector restarts Setting values are retained Restore basic settings Set settings and configuration to factory settings ...

Страница 20: ...h the SendoPro management remote control Error display Solution Hardware malfunction Send in device for repairs with a short description of the problem to the responsible specialised dealer Parameter error Change and send parameter set P terminal overload Fix parallel switching wiring malfunction 10 3 Diagnostic values The values can be reset using the SendoPro management remote control Value Desc...

Страница 21: ...rt up phase See page 70 Flickering during 3 sec The command sent from the management remote via infrared is rejected by the presence detector lights up shortly The command sent from the management remote via infrared is rejected by the presence detector The command is not valid Check the detector type selected in the SendoPro Fast blinking Error blinking The presence detector has found an error Se...

Страница 22: ... x 8 m seated persons 100 m2 10 x 10 m moving Mains voltage 230V 10 Frequency 50Hz Power consumption approx 0 3W Parallel switching max number of presence detectors 10 Connection type Screwless terminals 1x 2 5mm2 Strip length 10 11mm Receiving communication data sending data IR Radio 868 MHz Ambient temperature 0 50 C Storage temperature 25 60 C Protection rating IP 20 IP 40 when fitted ...

Страница 23: ... Installation type PlanoFix E installation frame Ceiling cut out 100 x 100 mm 1 mm Ceiling strength up to approx 26 mm Flush mounted installation concrete ceiling Installation type PlanoFix U flush mounted junction box Flush mounted junction box Agro Kaiser 115 x 115 x 100 mm 9908 01 1298 07 PlanoFix U installation plate Metal 118 x 118 mm ...

Страница 24: ...ted installation set black 204 0 203 PlanoCentro 000 USR flush mounted installation set silver 204 0 204 PlanoCentro 000 A 230V spare part 204 0 000 Management remote control SendoPro 868 A 907 0 675 SendoClic user remote control 907 0 690 PlanoCover EWH 112x112 white 907 0 677 PlanoCover EBK 112x112 black 907 0 678 PlanoCover ESR 112x112 silver 907 0 679 PlanoCover UWH 123x123 white 907 0 680 Pla...

Страница 25: ...81 GB 13 Dimension drawings 13 1 Ceiling installation PlanoCentro 000 E 13 2 Flush mount installation PlanoCentro 000 U 5 112 89 83 5 73 123 6 118 107 r 6 6 89 83 62 100 x 100 1 ...

Страница 26: ...irs to the devices that as long as the presence detector is connected to a software controlled system the war ranty for this connection is only valid if the interface specifications are adhered to We are obligated to improve or replace as quickly as possible all damaged or unusable parts within the scope of delivery proven insufficient materials faulty construction or lacking models up to the end ...

Страница 27: ...83 GB Subject to alteration and printing errors ...

Страница 28: ... 49 0 74 74 692 150 Hotline Tel 49 0 74 74 692 369 Fax 49 0 74 74 692 207 hotline theben de Theben HTS AG Im Langhag 7b CH 8307 Effretikon Tel 41 0 52 355 17 00 Fax 41 0 52 355 17 01 www theben hts ch Please find the contact addresses for additional countries on www theben de ...