background image

5

 

Special program 3 

¾

 Permanent  OFF

¾

Always off during the programmed date ranges 

Example

: The standard program switches on the car 

park lighting depending on the set lux values. The 

special program does not switch on the car park  

lighting on 14 July, from 00:00 to 15 July, 04:00.

Delete switching program

CHANNEL C1

 MENU

u

u

u

SINGLE

DELETE ALL

PROGRAM

NEW

CHECK

MODIFY

DELETE

STANDARD

EXTRA 1

EXTRA 2

EXTRA 3

DELETE ALL

END

¾

†

Press MENU

¾

†

Select PROGRAM and confirm with OK

¾

†

Select CHANNEL C1 or C2, confirm with OK

¾

†

Select STANDARD; EXTRA 1 or EXTRA 2, confirm with OK

¾

†

Select DELETE, confirm with OK

¾

†

Select SINGLE or DELETE ALL, confirm with OK

Allocate sensors

 

L

The SENSORS are allocated in the menu under OPTIONS

OPTIONS

MENU

SENSORS

OPERATING 

HOURS METER

EXT INPUT

CHANNEL 

COMBINATION

LCD  

ILLUMINATION

CHANNEL C1

1 SENSOR 

RECOGNISED

NO  

SENSOR

1 ACTIVE 

SENSOR

SENSOR 1

READING  

SENSOR 1

ACTIVE

DEACTIVATE

u

u

u

u

u

u

...

*

red LED flashes 

on the sensor

*

¾

†

Press MENU (see fig.)

Connection options:

 

1 LUNA + max. 4 light sensors

 

1 LUNA + max. 3 light s 1 DCF antenna

 

max. 10 LUNA

Σ

 max. 16 devices (LUNA + light sensors)

 

L

Presetting

: all connected sensors are active for all chan-

nels. The sensor that sends the lowest lux value is active

Activating PIN code

The PIN code is set in OPTIONS via the menu.

 

L

If you have forgotten your PIN, call the Theben Hotline.

 

L

Have the serial number ready

OPTIONS

NO PIN

WITH PIN

CURRENT PIN

NEW PIN

00 00

SENSORS

OPERATING

HOUR

EXT- INPUT

CHANNEL 

COMBINATION

LCD 

LLUMINATION

LANGUAGE

PIN

FACTORY

SETTING

INFO

END

u

u

MENU

Setting manual or permanent switching

Manual or permanent switching can be set via the menu in

MANUAL or (in the automatic screen) by button combination 

(see picture).

 

Manual control: 
Reversing the channel status to the next automatic or 
programmed switching.

 

Permanent switching: 
As long as a permanent switching (on or off) is acti-
vated, the programmed switching times and switching 
thresholds are ineffective

ok

Chanel  

C1

Chanel  

C2

Activating manual control

¾

†

Briefly press both buttons simultaneously

Activating permanent switching

¾

†

Press both buttons simultaneously for 2 seconds

Cancelling manual/permanent switching

¾

†

Press both buttons simultaneously

Содержание LUNA 121 top3 RC

Страница 1: ...ting the time switch Danger of death through electric shock or fire Installation should only be carried out by a qualified electrician WARNING click Test connection 45 cable Spring plug in terminal opener Bluetooth OBELISK top3 9070130 DuoFix spring plug in terminal Mount on DIN top hat rails as defined in EN 60715 Switched voltage free Ensure device cannot be switched on Check absence of voltage ...

Страница 2: ...sensor 0 25 1 5 mm2 strip cable by 8 mm max 9 mm max 10mm 8 9 mm ø 5 10 mm 9 mm ca 63mm IP 66 IP 40 Ø 20 mm 4 Device description Display buttons MENU OK OK MENU 0 6 12 18 24 Programmed switching times Date display Channel status C1 C2 ON On OFF Off Time display Days of the week from 1 to 7 Display of the active buttons with the relevant function Activate display Open menu Cancel menu ESC leave men...

Страница 3: ...ration 5 Settings and functions Set lux values LIGHT CHANNEL C1 LUX VALUE LUX ON Switch light off in the mornings Switch light on in the evening LUX OFF MONDAY MONDAY MONDAY 15 lx MONDAY 15 lx SAVE COPY COPY ADD TUESDAY ADD TUESDAY DELAY TIME END MENU u u u u u SAVE L LThe device has been preset at 15 lx for the switch on switch off level Press MENU Select LIGHT and press OK to confirm Select CHAN...

Страница 4: ...e or seve ral date ranges There are 3 types of date ranges Fixed date range e g start time on 02 04 2018 at 16 00 end time on 24 04 2018 at 10 00 Annually recurring date range e g Christmas start time on 24 12 at 18 00 each year end time on 26 12 at 23 00 each year Easter dependent date range e g Whit Sunday and Whit Monday start time 49 days after Easter at 00 00 end time each year 51 days after ...

Страница 5: ...4 light sensors 1 LUNA max 3 light sensors 1 DCF antenna max 10 LUNA Σ max 16 devices LUNA light sensors L LPresetting all connected sensors are active for all chan nels The sensor that sends the lowest lux value is active Activating PIN code The PIN code is set in OPTIONS via the menu L LIf you have forgotten your PIN call the Theben Hotline L LHave the serial number ready OPTIONS NO PIN WITH PIN...

Страница 6: ... not be swit ched at the same time The channels can be interlocked in this case LThe channel lock prevents both channels from switching on at the same time If a channel is already switched on the second channel will not switch on until the first channel is switched off and a waiting time of 1 s has passed If both channels are switched on at the same time channel 1 has priority OPTIONS OPERATING HO...

Страница 7: ... is selected the day of the week or EVERY DAY can be selected and the switchover hour must then be entered only full hours can be entered Finally the system returns to CHANNEL COMBINATION Hour counter The operating hours of the channel relay are displayed and deleted in the OPTIONS menu If the number of operating hours exceeds the value set in the Service menu SERVICE will appear in the display Ex...

Страница 8: ...two way switch Max switching capacity 16 A at 250 V cos ϕ 1 Switching capacity 10 A at 250 V cos ϕ 0 6 Min switching capacity 10 mA 230 V AC 100 mA 24 V AC DC Power reserve 10 years Shortest delay time 1 s Switching accuracy To the second Software Class A Rated impulse voltage 4 kV Pollution degree 2 Glow lamp load 2600 W Halogen lamp load 2600 W Fluorescent lamps KVG uncorrected series corrected ...

Отзывы: