41
The cold water pump is faulty. The system no longer receives feedback from the pump.
The system will stop cooling until the situation is restored.
ERROR 006
SOLUTION
1. Replace the cold water pump. To do this, contact your The Wine Square product
retailer.
The temperature sensor inside the
RC4LT
(in the wine cellar) is faulty. It communi-
cates with the system but it sends erroneous data. The system is therefore no longer
able to know the temperature of the cellar and to control it. The system will stop cooling
until the situation is restored.
ERROR 009
SOLUTIONS
1. Restart the system by turning off the power of the control box.
2. Using an RJ45 cable tester, check that the communication cable works well be-
tween the
RC4LT
and the control box.
3. Replace
RC4LT
control board. To do this, contact your The Wine Square prod-
uct retailer.