Make the hydraulic connection of the device accord-
ing to the following diagram. Any of the two tubes
coming from the
RC4LT
can be used for supply
or return to the unit. They can be reversed without
problem. The connections between the different
units must be made with the pre-insulated tubes
supplied with the device. The rubber tubes connect
directly to the PEX ferrules without a crimp ring.
• The tube closest to the middle of the control
box connects to the outlet closest to the floor
of the water chiller.
• The tube closest to the side of the control box
connects to one of the two pipes coming from
the RC4LT (in the wine cellar).
• The highest outlet of the water chiller con-
nects to one of the two pipes coming from
the RC4LT (in the wine cellar).
To facilitate installation, a few inches before the appli-
ance use a PEX union to pass from the rigid PEX pipe to
the pre-insulated flexible tubing supplied with the appli-
ance.
Make sure that the insulation covers the unions well to avoid any condensa-
tion. Use duct tape to cover the joints between the insulation sections.
CAUTION
Make sure you never power the water chiller unless there is wa-
ter in the system first.