MAINTAINING YOUR
POWERUV
™
CLARIFIER:
WARNING:
Before performing any maintenance, always unplug the PowerUV™ from the
power source.
Watch a video of the PowerUV
™
Clarifier maintenance online @
www.thepondguy.com/poweruv
Unscrew the Transformer
UNSCREW the transformer counter-clockwise and gently
pull the unit apart.
Remove Mounting Bracket
REMOVE the mounting bracket closest to the transformer
by flipping the unit over and removing the 2 screws with
your #2 Phillips screwdriver.
Remove Bulb Cap
REMOVE the rubber cap from the UV bulb and set aside.
Separate UV Housing
TWIST gently by holding both sides of the PowerUV™
housing to separate and expose the quartz sleeve.
Replace Bulb
PULL gently on the base of the UV-C bulb to remove. Install
new bulb. DO NOT touch the bulb with bare hands. Verify
that the O-Ring is seated properly on the transformer before
screwing it onto the UV housing. UV-C bulb should be
replaced yearly.
See REPLACEMENT PARTS for replacement bulbs.
Clean
CLEAN quartz sleeve with a soft cloth or sponge and
reassemble unit. Quartz sleeve should be replaced if it is
scratched, damaged or cracked. See REPLACEMENT PARTS
for replacement quartz sleeve and housing.
Tools Required: #2 Phillips Screwdriver, soft cloth & descaler.
*Note: For your safety, the PowerUV™ will not operate without the UV housing and
transformer securely connected.
If water is not clear, check the following:
• Check the viewing window to ensure the UV-C bulb is lit.
• Replace UV-C bulb if it has not been replaced in the past year, even if it is lit.
• Check that the quartz sleeve is clean.
• Verify that the proper amount of water is flowing through the UV. See recommendation
for proper water flow under Technical Specs.
Loss of water flow from the UV, check the following:
• Verify pump is not plugged with debris.
• Verify biological filter is not plugged with debris.
thepondguy.com | 866-POND-HELP (766-3435)
15425 Chets Way | Armada, MI 48005
6