Installation & Operation Manual
to any value greater than 0.
4.5.5 Date Offset
This field is used to select a forward offset, in days, to the current date. If the “Date Offset” value is selected as 0, the
current date will be displayed.
4.6 Other
4.6.1 Unit Name
This can be any alpha numeric name up to 20 characters long.
4.6.2 Password
The password field displays the current password. To change it, enter a new password, push Set and Restart Clock.
TMPC passwords are limited to12 characters. The default password is “tmachine”.
4.6.3 Alarms
The TMPC has the capability of signaling 24 alarms throughout the course of a single day. Alarm entries are to be
separated by semicolons with no spaces. The hour, entered in 24 hour time, at which the alarm is to be set off is entered
first and followed by the minute, the two are to be separated by a colon. The last entry is the duration, in seconds, that the
alarm is to sound, it is limited to a maximum of 59 seconds. The minutes and seconds are to be separated by a single
dash. Simply deleting an alarm from the form won't disable the alarm, the next time the web page is brought up the alarm
will still be shown and still be active. In order to deactivate an alarm the duration must be set to 0. Only then will the alarm
no longer be listed when the web page is revisited. The default setting is to have no alarms set. Example alarm string: 8:0-
3;12:0-3;13:0-3;17:0-3. This example string sets 4 alarms all on the hour and for a duration of 3 seconds.
4.6.4 Brightness
This parameter allow the user to control the brightness of the display. There are three settings that are selectable.
• DEFAULT, the brightest setting
• MEDIUM
• LOW, the lowest setting.