background image

Page 6

Pump & Pipe 
Installation Instructions

INSTALLATION C:
DIRECT DISCHARGE TO THE OUTSIDE OF THE
BUILDING FOR NARROW SUMP PITS 
(Diagram C)

Unplug the main AC pump when installing
the backup pump to avoid electric shock.
Failure to do so could cause serious injury or
death.

1. Attach an “L” bracket to the discharge pipe of

the main AC pump with two (2) stainless steel
hose  clamps.    Position  the  bracket  so  the
bottom of the “L” is just above the top of the
main  pump,  and  out  of  the  way  of  any  float
switch on the main pump.

2. (a)  Remove  the  black  bottom  strainer  of  the

pump  by  pressing  in  the  two  tabs  on  the
strainer  and  pushing  down.    There  are  holes
suitable  for  mounting  on  the  bottom  of  the
strainer.  (b) Using the #8-32 x ¾” stainless
screw, washer and nut, attach the strainer to

the  “L”  bracket.    (c)  Once  the  strainer  is
attached,  simply  press  the  rest  of  the  pump
onto the mounted strainer.

3. Secure the pump wire so that the plug on the

end  will  not  fall  into  the  sump.    Attach  the
wire to the pipe with a piece of tape.

4. Cut a piece of 1½” rigid PVC pipe long enough

to reach from the elbow of the backup pump
to (1) foot above the floor.  Prime and cement
it  to  the  1½”  pipe  adapter,  then  screw  the
adapter into the pump.

5. Attach  a  union  or  check  valve  to  the  top  of

the 1½” PVC pipe.  This will allow the pump
to be removed easily, should the need arise.

The path of the rest of the pipe and the details
of  each  installation  will  vary.    Using  sound
plumbing practices, route the discharge pipe to
an  exterior  wall  via  the  shortest  path  with  the
fewest  turns. More  turns  will  reduce  the
pumping capacity.  The pipe section exiting the
building should be on a downward slope so that
the water in the pipe will exit outside instead of
returning to the sump pit.  Be sure to seal the
hole in the wall where the pipe exits, and prime
and cement or clamp all connections securely to

prevent leaking.  (No check valve is needed with
this  method  of  installation  as  long  as  you  use
less than 20 feet of pipe.) 

If you use more than a total of 20 feet of pipe
in  the  installation  (including  vertical  and
horizontal runs), install a check valve in place
of the union.  Make sure it is installed with the

arrow  pointing  up  or  it  will  not  prevent  the
backflow of water.  When a check valve is used,
a  1/8”  hole  must  be  drilled  in  the  PVC  pipe
above the Basement Watchdog pump.  Drill the
hole at a 45° angle toward the bottom of the
sump  to  avoid  splashing  water  outside  the
sump  pit.    Make  sure  the  hole  is  above  the
water line, and below the check valve.  If a hole
is not drilled above the pump, an air lock may
prevent the pump from operating.

Diagram C

CAUTION

!

DANGER

PUMP WIRE

CHECK
VALVE

HOSE 
CLAMPS
1/8” HOLE

"L" BRACKET

FLOOR

JOIST

MAIN 
A
BRICKS

C PUMP

RIGID

1-1/2"

PVC PIPE

UNION

OR CHECK

VALVE

   

PIPE ADAPTER

DRILL 1/8" HOLE

IF CHECK

VALVE USED

DRAIN   TILE

SLOPE

PIPES
DOWN

BASEMENT

WATCHDOG

PUMP

2c

4

5

3

1

2b

2a

“L”  BRACKET

Содержание Special CONNECT

Страница 1: ...ge for Narrow Sumps 7 Battery Instructions Preparation of the Battery 8 9 Control Unit Connections Positioning the Float Switch 9 Connecting the Pump 9 Installing the Battery Fluid Sensor 10 Connectin...

Страница 2: ...observe the following precautions Someone should be within range of your voice or close enough to come to your aid when you work near a lead acid battery Have plenty of fresh water and soap nearby in...

Страница 3: ...mps or a Y connector and two 2 check valves depending on the installation method you use A surge protector recommended Six 6 quarts of 1 265 specific gravity battery acid 30HDC140S and BW 30F Battery...

Страница 4: ...ove the main AC pump Try to fit the backup pump on the floor of the sump first Make sure there is enough room so that the backup pump and the main pump do not touch each other Select the installation...

Страница 5: ...he discharge pipe to an exterior wall via the shortest path with the fewest turns More turns will reduce the pumping capacity The pipe section exiting the building should be on a downward slope so tha...

Страница 6: ...ed at this time Cut the discharge pipe approximately one 1 foot above the floor Install a check valve on the top of the pipe and tighten the bottom hose clamp Now prime and cement a small piece of 1 P...

Страница 7: ...e path of the rest of the pipe and the details of each installation will vary Using sound plumbing practices route the discharge pipe to an exterior wall via the shortest path with the fewest turns Mo...

Страница 8: ...he Basement Watchdog pump Make sure it is installed with the arrow pointing up or it will not prevent the backflow of water 6 When a check valve is used a 1 8 hole must be drilled in the PVC pipe abov...

Страница 9: ...IS PAGE IF THE TOP OF YOUR BATTERY LOOKS LIKE PHOTO B ON PAGE 9 FOLLOW THE INSTRUCTIONS ON PAGE 9 Contains sulfuric acid Wear eye and clothing protection If battery acid contacts skin or clothing wash...

Страница 10: ...uously The system will NOT warn you if the fluid level is low in this configuration You will need to check your battery every couple of months to see if it needs water If the battery dries out the sys...

Страница 11: ...see if it needs water If the battery dries out the system will not work If you are using a maintenance free battery or sealed AGM battery you will also need to attach the fluid sensor to the POSITIVE...

Страница 12: ...the battery should recharge If no other lights are on this means the terminals may be corroded and the battery cannot charge properly Unplug the charger from the wall outlet Then check the battery ca...

Страница 13: ...he wall outlet You should provide additional protection for the control unit by using a surge protector 10 If any of the alarms are sounding press the YELLOW button on the front of the control panel f...

Страница 14: ...disconnect the battery cables from the battery Then call Glentronics technical support for instructions at 800 991 0466 option 3 You may need to replace the pump 4 Plug the main AC pump back into the...

Страница 15: ...ing up 3 Fan the area around the top of the battery with a piece of cardboard or another non metallic material to remove any hydrogen or oxygen gas that may have been emitted from the battery 4 Remove...

Страница 16: ...be taken to prevent a flood To silence certain alarms for 24 hours press the YELLOW button for 5 seconds until you hear a buzz The alarms will automatically re activate in 24 hours TESTING THE FLOAT S...

Страница 17: ...sit www BasementWatchdog com MAINTENANCE CHECK LIST Maintenance should be performed 1 2 times per year 1 Lift the float switch as described at left 2 Remove all debris from the bottom of the pit and p...

Страница 18: ...ower cord is plugged in securely None if the utility company has instigated brown outs Otherwise reduce the number of other appliances on the circuit Make sure the pump is securely plugged into the ba...

Страница 19: ...ed below GLENTRONICS INC at its option will either repair or replace the product and return it postage prepaid What is NOT Covered by this Warranty This warranty does not cover the cost or value of da...

Страница 20: ...e cage Should one float fail to operate the second float automatically activates the pump The protective cage prevents debris or other wires from interfering with the movement of the float It can be u...