The Basement Watchdog Big Combo Скачать руководство пользователя страница 9

Page 8

4. Remove  the  fluid  sensor  from  the  battery.

Unscrew  the  wing  nuts.    Remove  the  battery
cables.

5. Clean  the  battery  posts  with  a  battery

terminal cleaner or a wire brush.

6. Clean any corrosion off of the ring connectors on

the ends of the battery wires.  Us a stiff brush
or sandpaper.  

DO NOT

apply corrosion resisting

sprays  or  pads  to  the  terminal  rings  or  posts
after  you  have  cleaned  them,  since  this  could
prevent the system from charging properly.

7. Replace  the  fluid  sensor  in  the  top  of  the

battery.    Then  replace  the  battery  cables,
BLACK  to  the  NEGATIVE  (-)  post  and  RED  to
the POSITIVE (+) post.  Tighten the wing nuts.
Replace the cover on the battery box.

8. Plug  the  charger

and  the  blue  AC
pump 

controller

back  into  the  wall
outlet. 

9. If any of the alarms

are sounding, press
the  YELLOW  button
on the front of the
control panel for one (1) second.

REPLACING THE BATTERY

Risk of electrical shock or battery explosion,
which can cause serious injury or death.
Wear eye protection.  Work in a well-
ventilated area.  Do not smoke or allow a
spark or flame in the vicinity of the battery.
Avoid dropping metal tools on the battery.
If battery acid contacts eyes, flush with
water for 15 minutes and get prompt
medical attention. Review the safety
instructions on page 1.

REFER TO THE PHOTOS AT RIGHT

1. Unplug  the  charger  and  the  blue  AC  pump

controller from the wall outlet.

2. Remove  the  cover  of  the  battery  box  by

pushing  in  the  tabs  on  the  front  and  back,
then lifting up.

3. Fan  the  area  around  the  top  of  the  battery

with  a  piece  of  cardboard  (or  another  non-
metallic material) to remove any hydrogen or

oxygen  gas  that
may  have  been
emitted  from  the
battery.

4. Remove  the  fluid

sensor  from  the
top 

of 

the

battery.  Unscrew
the  wing  nuts
and  remove  the
battery cables.

5. Remove the old battery from the battery box

and place the new battery in the box.  Fill the
battery  following  the  instructions  on  page  4
or 5.

6. Clean any corrosion off of the ring

connectors on the ends of the battery wires.
Use a stiff brush or sandpaper.  

DO NOT

apply corrosion resisting sprays or pads to
the terminal rings or posts after you have
cleaned them, since this could prevent the
battery from charging properly.

7. Replace  the  battery  cables,  BLACK  to  the

NEGATIVE  (-)  post  and  RED  to  the  POSITIVE
(+) post.  Tighten the wing nuts.

8. (a) If your battery has six (6) caps on the top,

rinse and dry the cap with the extra hole from
the old battery to remove any residue.  Replace
the battery cap in the cell that is 2nd from the
POSITIVE  post  with  the  cap  from  the  old
battery.  Insert the fluid sensor in the cap.  (b)
If  your  battery  has  two  caps,  each  covering
three (3) battery cells, simply insert the fluid
sensor  in  the  top  of  the  battery  next  to  the
arrow.  Replace the cover on the battery box.

9. Plug  the  charger  and  the  blue  AC  pump

controller back into the wall outlet. 

10. If any of the alarms are sounding, press the

YELLOW  button  on  the  front  of  the  control
panel for one (1) second.

!

DANGER

8

7

5

6

2

3

4

Remove

POSITIVE

POST

NEGATIVE

POST

7

5

6

4

2

3

Remove

POSITIVE

POST

NEGATIVE

POST

8a

8b

9

Содержание Big Combo

Страница 1: ...ting the charger 6 Connecting the primary pump 6 Product Operation 6 Understanding the Warning Lights and Alarms Silencing the alarm during an emergency 7 Battery alarm 7 Cleaning the battery terminal...

Страница 2: ...tact Glentronics technical support at 800 991 0466 option 3 Return the product to the manufacturer for any repairs at the following address Glentronics Inc 645 Heathrow Drive Lincolnshire IL 60069 BAT...

Страница 3: ...ms have been pre assembled for easy installation For added reliability the float switches have not one but two floats Should one float fail to operate the second float automatically activates the pump...

Страница 4: ...19 inches the height of the pump system 1 inch Cut a piece of 1 1 2 rigid PVC pipe to that length 4 a Connect this piece to the discharge pipe by cementing the two pieces together with a 1 1 2 PVC pi...

Страница 5: ...like photo A follow the instructions on this page If the top of your battery looks like photo B on page 5 follow the instructions on page 5 Contains sulfuric acid Wear eye and clothing protection If...

Страница 6: ...d distilled water to the cells NEVER add more acid If your battery looks like the battery above follow these directions 1 Remove the cover of the battery box by pushing the tabs on the front and back...

Страница 7: ...the charger into the charger jack on the back of the control unit then into an AC outlet on the wall 7 If the pump alarm is sounding press the YELLOW button to silence the alarm 8 Replace the cover o...

Страница 8: ...y is the problem is to have it charged and load tested at any local car service station If the battery is bad and less than one 1 year old it can be returned to the place of purchase for a replacement...

Страница 9: ...on the front and back then lifting up 3 Fan the area around the top of the battery with a piece of cardboard or another non metallic material to remove any hydrogen or oxygen gas that may have been e...

Страница 10: ...f electrical shock or battery explosion which can cause serious injury or death Wear eye protection Work in a well ventilated area Do not smoke or allow a spark or flame in the vicinity of the battery...

Страница 11: ...y do not touch each other while one is connected to the battery 6 Slowly loosen the rubber union on the top of the combination pump assembly to separate the pipes The water trapped in the pipe will po...

Страница 12: ...o the other side of the Y connector with the other no hub connector 20 Replace the caged float switch by tightening it with its hose clamp 21 Replace the backup pump float switch using 2 new cable tie...

Страница 13: ...ting TESTING THE PRIMARY PUMP FLOAT SWITCH Lift the float within the cage with a pencil or other non metallic item and let it drop The pump will run for an additional 10 seconds after the float return...

Страница 14: ...ubscriptions Model No BW WiFi Basement Watchdog Home Automation Module Model No BW HZM Easily connects to compatible monitored security or home automation system Connects using Z Wave Plus Model No BW...

Страница 15: ...k of the controller The control unit is receiving less than 110 volts from the outlet Backup pump is clogged Backup pump is broken There is a slight chance of false activation if the float switch cord...

Страница 16: ...e address listed below GLENTRONICS INC at its option will either repair or replace the product and return it postage prepaid What is NOT Covered by this Warranty This warranty does not cover the cost...

Отзывы: