The Basement Watchdog Big Combo Скачать руководство пользователя страница 13

Page 12

6

Charging  

The  Basement  Watchdog  backup  system  is
equipped with a computer-controlled automatic
charging  system.    The  computer  is  constantly
monitoring  the  battery  and  will  supply  a  pre-
programmed  amount  of  energy  to  keep  your
battery at full charge.  The “Charging” light will
be on or flashing while the battery is charging,
and off when it is not charging.  If the battery
is  discharged  from  extended  use,  the  charger
light  will  remain  on  until  the  battery  is
completely recharged.

7

System Operating

This light will always be on when there is power
coming from either the battery or the outlet.

TEST-RESET-SILENCE BUTTON

To test the pump, press the YELLOW button for 1
second.    The  pump  will  run  for  2  seconds  and
then shut off automatically.

To silence an alarm, press the YELLOW button for
1 second.  Some alarms cannot be silenced since
action needs to be taken to prevent a flood.

To reset the BATTERY or PUMP alarm, press the
button  for  1  second.    To  silence  them  for  24
hours,  press  the  YELLOW  button  for  5  seconds

until  you  hear  a  buzz.    The  alarms  will
automatically re-activate in 24 hours

TESTING THE BACKUP FLOAT SWITCH

It  is  important  to  manually  test  the  float
switch periodically or after any maintenance.

Lift  the  float  up  and  let
go.  This will activate the
pump.    The  control  unit
will  run  the  pump  for
approximately 25 seconds
so  it  can  empty  all  the
water in the sump pit.  If
there  is  no  water  in  the
pit, the pump can run dry
for  this  amount  of  time.
The alarm will sound and
the  PUMP  light  will  go  on.  After  the  pump  has
stopped, push the YELLOW button to silence the
alarm.  If the YELLOW button is pressed before the
pump  has  stopped,  the  alarm  will  go  off
temporarily.  Wait for the pump to stop pumping,
and then push the YELLOW button to completely
silence the alarm.

While the pumps are active, water will come out
of the 1/8” holes located on the top of the main
pump  and  in  the  elbow  of  the  backup  pump.
This is normal.  The holes are needed to prevent
an air lock within the system.  

DO NOT

obstruct

the holes or an air lock may prevent the system
from activating.

TESTING THE PRIMARY PUMP 
FLOAT SWITCH

Lift the float within
the  cage  with  a
pencil or other non-
metallic item  and
let  it  drop.    The
pump  will  run  for
an  additional  10
seconds  after  the
float returns to the
original position.  It will not damage the pump
to run it for this short time if the sump pit is dry.
However, 

DO NOT 

hold  the  float  up  for  an

extended time without water in the sump.
While the pumps are active, water will come out
of the 1/8” holes located on the top of the main
pump  and  in  the  elbow  of  the  backup  pump.
This is normal.  The holes are needed to prevent
an air lock within the system.  

DO NOT

obstruct

the holes or an air lock may prevent the system
from activating.

Using the Remote
Notification

THE REMOTE TERMINAL

The  BW4000  can  be  connected  to  a  home
security  system  or  other  alarm  devices  to  alert
you to a problem or required maintenance.

INSTRUCTIONS FOR CONNECTING THE
REMOTE ALARM

The  terminal  is  located  on  the  front  of  the
control  unit.    There  are  three  (3)  positions  for
wire  connections  on  the  terminal:  N.O.  –
normally  open,  N.C.  -  normally  closed,  and
common.
Check your security system to determine whether
an open (no contact) or closed (making contact)
connection is needed to activate the alarm.
The security system will provide two connection
terminals.    You  will  need  to  extend  wires  from
the  security  system  to  the  Basement  Watchdog
control  unit.    Strip  the  two  wires,  ¼”  each.
Connect either wire to the common terminal.  To
secure  the  wire  into  the  terminal,  insert  the
exposed  wire  into  the  hole  on  the  back  of  the
terminal  next  to  the  screw  marked  common.
Turn the screw a few turns to lock-in the wire.
If  the  security  system  requires  a  closing  of  a
contact to activate the alarm, secure the other
wire in the terminal hole labeled N.O. (normally
open).    If  the  security  system  requires  an
opening  of  a  contact,  secure  the  wire  in  the
terminal hole labeled N.C. (normally closed).

USB DATA PORT

This  system  has  been
updated with a USB port
on  the  side  of  the
controller.  The  purpose
of  this  port  is  to  allow
communication with the
Basement Watchdog
CONNECT® Modules.

CONNECT MODULES

The Basement Watchdog CONNECT® Modules are
separately  sold  accessories  that  will  allow  the
user  to  stay  connected  and  receive  remote

2

3

FUSE

CHARGER

PUMP

LIFT

FLOAT

LIFT

FLOAT

Содержание Big Combo

Страница 1: ...ting the charger 6 Connecting the primary pump 6 Product Operation 6 Understanding the Warning Lights and Alarms Silencing the alarm during an emergency 7 Battery alarm 7 Cleaning the battery terminal...

Страница 2: ...tact Glentronics technical support at 800 991 0466 option 3 Return the product to the manufacturer for any repairs at the following address Glentronics Inc 645 Heathrow Drive Lincolnshire IL 60069 BAT...

Страница 3: ...ms have been pre assembled for easy installation For added reliability the float switches have not one but two floats Should one float fail to operate the second float automatically activates the pump...

Страница 4: ...19 inches the height of the pump system 1 inch Cut a piece of 1 1 2 rigid PVC pipe to that length 4 a Connect this piece to the discharge pipe by cementing the two pieces together with a 1 1 2 PVC pi...

Страница 5: ...like photo A follow the instructions on this page If the top of your battery looks like photo B on page 5 follow the instructions on page 5 Contains sulfuric acid Wear eye and clothing protection If...

Страница 6: ...d distilled water to the cells NEVER add more acid If your battery looks like the battery above follow these directions 1 Remove the cover of the battery box by pushing the tabs on the front and back...

Страница 7: ...the charger into the charger jack on the back of the control unit then into an AC outlet on the wall 7 If the pump alarm is sounding press the YELLOW button to silence the alarm 8 Replace the cover o...

Страница 8: ...y is the problem is to have it charged and load tested at any local car service station If the battery is bad and less than one 1 year old it can be returned to the place of purchase for a replacement...

Страница 9: ...on the front and back then lifting up 3 Fan the area around the top of the battery with a piece of cardboard or another non metallic material to remove any hydrogen or oxygen gas that may have been e...

Страница 10: ...f electrical shock or battery explosion which can cause serious injury or death Wear eye protection Work in a well ventilated area Do not smoke or allow a spark or flame in the vicinity of the battery...

Страница 11: ...y do not touch each other while one is connected to the battery 6 Slowly loosen the rubber union on the top of the combination pump assembly to separate the pipes The water trapped in the pipe will po...

Страница 12: ...o the other side of the Y connector with the other no hub connector 20 Replace the caged float switch by tightening it with its hose clamp 21 Replace the backup pump float switch using 2 new cable tie...

Страница 13: ...ting TESTING THE PRIMARY PUMP FLOAT SWITCH Lift the float within the cage with a pencil or other non metallic item and let it drop The pump will run for an additional 10 seconds after the float return...

Страница 14: ...ubscriptions Model No BW WiFi Basement Watchdog Home Automation Module Model No BW HZM Easily connects to compatible monitored security or home automation system Connects using Z Wave Plus Model No BW...

Страница 15: ...k of the controller The control unit is receiving less than 110 volts from the outlet Backup pump is clogged Backup pump is broken There is a slight chance of false activation if the float switch cord...

Страница 16: ...e address listed below GLENTRONICS INC at its option will either repair or replace the product and return it postage prepaid What is NOT Covered by this Warranty This warranty does not cover the cost...