Page 5

This  backup  system  will  also  accommodate  a
maintenance-free  battery,  eliminating  the  need
to fill the battery.  The fluid sensor is not needed
when  using  maintenance-free  batteries.
However,  you 

MUS

T  attach  the  fluid  sensor  to

the  positive  post  of  the  battery  to  silence  the
fluid alarm.

Battery Maintenance

Measuring  the  battery  fluid  level  is  one  of  the
most  important  features  of  the  system.  It  is
important  to  check  the  battery  fluid  levels  at
least  once  every  4-6  months.  Detailed
instructions  on  adding  distilled  water  to  the
battery can be found within the 

Understanding

the Warnings & Alarms

section of this manual

(page  9, 

3

Water

).  If  you  are  not  using  a

Basement Watchdog standby battery, you cannot
use  the  battery  fluid  sensor.  You  will  need  to
attach the fluid sensor to the POSITIVE (+) post
of  the  battery  or  the  alarm  will  sound
continuously.  The  system  will  NOT  warn  you  if
the fluid level is low in this configuration. You
will need to check your battery every couple of
months  to  see  if  it  needs  water.  If  the  battery
dries  out,  the  system  will  not  work.  If  you  are
using a maintenance free battery or sealed AGM
battery  you  will  also  need  to  attach  the  fluid
sensor to the POSITIVE (+) post of the battery or
the or the alarm will sound continuously.

System Connections

Risk of electrical shock or battery explosion,
which can cause serious injury or death.
Unplug the main AC pump to avoid electrical
shock.  Wear eye protection.  Work in a well-
ventilated area.  Do not smoke or allow a
spark or flame in the vicinity of the battery.

Avoid dropping metal tools on the battery.
If battery acid contacts eyes, flush with
water for 15 minutes and get prompt
medical attention.  Review the safety
instructions on page 1.

MOUNTING THE CONTROLLER

When you position the battery with the control
unit  on  the  top,  be  sure  the  charger  cord  will
reach the AC power outlet, and the pump cable
and  float  switch  will  reach  the  bottom  of  the
sump.    Position  the  unit  in  a  well-ventilated
area. (Diagram C)

1. 

Mounting  the  backup  control  unit:

(a)

Thread  the  wires  on  the  backup  controller
through  the  hole  in  the  top  of  the  battery
box.  (b) Secure the controller to the top of

When you fill the battery for the FIRST time, it
will  be  the  ONLY  time  you  add  acid  to  the
battery.  In the future, when the fluid level is
low, add distilled water to the cells.  NEVER add
more acid.

If  your  battery  looks  like  the  battery  above,
follow these directions.

1. Remove  the  cover  of  the  battery  box  by

pushing the tabs on the front and back of the
box and lifting up. Place the battery box on
the floor. Place the dry (unfilled) battery into
the battery box.  

2. Remove  the  two  battery  caps  by  carefully

prying them up with a screwdriver.  Place the
screwdriver in the groove in the middle of the
cap on the top of the battery.  DO NOT lift the
cap  by  prying  it  up  from  the  groove  on  the
side of the battery.  It may damage the vent.

3. Carefully push in the perforated tab at the top

of  the  acid  pack.    Lift  up  the  large  tab  and
pull out the dispensing hose.  Hold the hose
upright above the pack and squeeze the hose
forcing all the acid back into the pack.  

4. Position the acid pack and battery as shown

at  the  right.    Pinch  the  end  of  the  hose
together and cut off the tip.  Insert the end
of the hose into each cell.  Control the flow
by  pinching  the  hose  with  thumb  and
forefinger

.  

Fill each cell of the battery to a

level  just  covering  the  battery  plates,  and
then go back and top off each cell equally.
It is important to have all of the cells filled
equally or  the  battery  will  not  operate
properly.

The acid should reach a level about

1/4”  below  the  cap  rings.    You  may  top  off
each  cell  with  a  little  distilled  water,  if
necessary.  DO  NOT  OVERFILL  THE  BATTERY.
(Diagram B)

A  newly  filled  battery  will  sometimes  require
additional  acid  after  about  ten  minutes.
Reexamine the fill level and add additional acid,
if necessary.  The battery acid may bubble at this
time and give off a sulfur-like smell, but this is
normal.  After the battery has been filled, press
the two caps on the top of the battery.

The battery will be charged 70%-80% 30 minutes
after adding the acid.  The system will then finish
charging the battery.  During this time the alarm
may sound. 

When you fill the battery for the FIRST time,
it will be the ONLY time you add acid to the
battery.  In the future, when the fluid level is
low,  add  distilled  water  to  the  cells.    Never
add more acid.

!

DANGER

1a

1b

4

BATTERY B

CAUTION

2

PRIMARY

PUMP

WIRE

PRIMARY

FLOAT

WIRE

BATTERY

BOX

DRAIN   TILE

AC OUTLET

BACKUP

PUMP

CHARGER

PRIMARY

PUMP

CONTROLLER

BACKUP PUMP
FLOAT SWITCH

BACKUP

PUMP

PRIMARY PUMP
FLOAT SWITCH

PRIMARY
PUMP

BACKUP PUMP

CONTROLLER

BACKUP

PUMP

WIRE

BACKUP

FLOAT

WIRE

CABLE TIE

CABLE TIE

RUBBER
UNION

SUMP PIT COVER

FLOOR

JOIST

SLOPE

PIPE

DOWN

BRICKS

Diagram C

FUSE

PUMP

CHARGER

3

2

1

CAUTION

Содержание Big Combo

Страница 1: ...ting the charger 6 Connecting the primary pump 6 Product Operation 6 Understanding the Warning Lights and Alarms Silencing the alarm during an emergency 7 Battery alarm 7 Cleaning the battery terminal...

Страница 2: ...tact Glentronics technical support at 800 991 0466 option 3 Return the product to the manufacturer for any repairs at the following address Glentronics Inc 645 Heathrow Drive Lincolnshire IL 60069 BAT...

Страница 3: ...ms have been pre assembled for easy installation For added reliability the float switches have not one but two floats Should one float fail to operate the second float automatically activates the pump...

Страница 4: ...19 inches the height of the pump system 1 inch Cut a piece of 1 1 2 rigid PVC pipe to that length 4 a Connect this piece to the discharge pipe by cementing the two pieces together with a 1 1 2 PVC pi...

Страница 5: ...like photo A follow the instructions on this page If the top of your battery looks like photo B on page 5 follow the instructions on page 5 Contains sulfuric acid Wear eye and clothing protection If...

Страница 6: ...d distilled water to the cells NEVER add more acid If your battery looks like the battery above follow these directions 1 Remove the cover of the battery box by pushing the tabs on the front and back...

Страница 7: ...the charger into the charger jack on the back of the control unit then into an AC outlet on the wall 7 If the pump alarm is sounding press the YELLOW button to silence the alarm 8 Replace the cover o...

Страница 8: ...y is the problem is to have it charged and load tested at any local car service station If the battery is bad and less than one 1 year old it can be returned to the place of purchase for a replacement...

Страница 9: ...on the front and back then lifting up 3 Fan the area around the top of the battery with a piece of cardboard or another non metallic material to remove any hydrogen or oxygen gas that may have been e...

Страница 10: ...f electrical shock or battery explosion which can cause serious injury or death Wear eye protection Work in a well ventilated area Do not smoke or allow a spark or flame in the vicinity of the battery...

Страница 11: ...y do not touch each other while one is connected to the battery 6 Slowly loosen the rubber union on the top of the combination pump assembly to separate the pipes The water trapped in the pipe will po...

Страница 12: ...o the other side of the Y connector with the other no hub connector 20 Replace the caged float switch by tightening it with its hose clamp 21 Replace the backup pump float switch using 2 new cable tie...

Страница 13: ...ting TESTING THE PRIMARY PUMP FLOAT SWITCH Lift the float within the cage with a pencil or other non metallic item and let it drop The pump will run for an additional 10 seconds after the float return...

Страница 14: ...ubscriptions Model No BW WiFi Basement Watchdog Home Automation Module Model No BW HZM Easily connects to compatible monitored security or home automation system Connects using Z Wave Plus Model No BW...

Страница 15: ...k of the controller The control unit is receiving less than 110 volts from the outlet Backup pump is clogged Backup pump is broken There is a slight chance of false activation if the float switch cord...

Страница 16: ...e address listed below GLENTRONICS INC at its option will either repair or replace the product and return it postage prepaid What is NOT Covered by this Warranty This warranty does not cover the cost...

Отзывы: