Cinterion
®
DGL61-W Hardware Interface Description
7.2 Restrictions
40
t
DGL61-W_HID_v07
2021-02-17
Public / Preliminary
Page 38 of 42
7.2
Restrictions
Later enhancements and modifications beyond the certified configuration require extra approv-
als. Each supplementary approval process includes submittal of the technical documentation
as well as testing of the changes made.
•
No further approvals are required for customer applications that comply with the approved
DGL61-W configuration.
•
Extra approval must be obtained for applications using other accessories than those
included in the approved DGL61-W configuration (power supply, MMI implementation sup-
ported by AT commands).
7.3
CE Conformity
The DGL61-W meet the requirements of the EU directives listed below:
•
RED Directive 2014/53/EU
The Device Gateway LTE are marked with the CE conformity mark (without a notified body
number):
7.4
EMC
The DGL61-W comply with the equipment requirements specified in EN 301489-1, and -52 are
covered by the RED Directive. For details see
7.5
RF Exposure Information
DGL61-W has been tested and meets applicable limits for radio frequency (RF) exposure.
The SAR (Specific Absorption Rate) limit is 1.6 watts per kilogram in countries that set the limit
averaged over 1 gram of tissue, and 2.0 watts per kilogram in countries that set the limit aver-
aged over 10 grams of tissue. During testing, DGL61-W radios are set to their highest trans-
mission levels and SAR is evaluated according to the regulations. DGL61-W is evaluated in
positions that simulate uses when worn or carried against the torso of the body, with 5mm and
10mm separation.
Conformity mark
Table 17:
Highest reported SAR
Condition
DGL61-W
highest reported SAR Limit
1g(W/kg) in body-worn condition,
10mm separation distance according to FCC
1.6 W/kg
1.6 W/kg
10g(W/kg) in body-worn condition, 5mm separation
distance according to RED Directive
1.98 W/kg
2.0 W/kg