5.5 Operating Temperatures
33
t
DGL61-W_HID_v07
2021-02-17
Public / Preliminary
Page 32 of 42
5.5
Operating Temperatures
Note: Within the specified operating temperature ranges the board temperature may vary to a
great extent depending on operating mode, used frequency band, radio output power and cur-
rent supply voltage. Note also the differences and dependencies that usually exist between
board (PCB) temperature of the Java module and its ambient temperature.
Table 15:
Temperature characteristics
Parameter
Min
Typical
Max
Unit
Normal (unlimited) Operation
-30
+50°C
°C
Extended Operation
+60
1
to +70
2
1. Maximum time to transmit to keep DGL61-W below the automatic thermal restart limit. 50s
Maximum transmit to idle ratio to keep DGL61-Wbelow the automatic thermal restart limit: 1:3
Both condition, max time and ratio, mustn't be violated to keep DGL61-W in a safe operation condi-
tion without thermal restart, e.g. 10/30s, 20/60s etc. If one condition is violated, e.g. transmit time
60s or ratio 1:2, the DGL61-W will automatic restart when it reached the maximum board tempera-
ture (dependent on the transmit level).
Test condition: LTE upload @23dBm, still air.
2. Maximum time to transmit to keep DGL61-W below the automatic thermal restart limit. 30s
Maximum transmit to idle ratio to keep DGL61-Wbelow the automatic thermal restart limit: 1:6
Both condition, max time and ratio, mustn't be violated to keep DGL61-W in a safe operation condi-
tion without thermal restart, e.g. 10/60s, 20/120s etc. If one condition is violated, e.g. transmit time
60s or ratio 1:5, the DGL61-W will automatic restart when it reached the maximum board tempera-
ture (dependent on the transmit level).
Test condition: LTE upload @23dBm, still air.
°C
Automatic thermal restart
3
,
4
3. PCB Board temperature of module.
4. Due to temperature measurement uncertainty, a tolerance of ±3°C on these switching thresholds
may occur.
<-40
>+90
°C