In case of the autonomous use, the detector will notify of the detected fire/smoke with a sound
signal and light of the logo. To switch off the siren sound, press on the logo (there is a touch-
sensitive button under it) or eliminate the cause of the actuated alarm.
Detector Maintenance and Battery Replacement
Check the operational capability of the FireProtect detector on a regular basis.
Clean the detector body from dust, spider web and other contaminations as they appear with a
soft dry napkin suitable for equipment maintenance.
Do not use for cleaning any substances containing alcohol, acetone, gasoline and other active
solvents.
Any dust that penetrated into the smoke chamber is perceived by the detector as smoke. The
dust content of the chamber is compensated up to some level, and then cleaning will be
required - the detector will send the respective notification. The detector also signals about the
contaminated smoke chamber or a failure using a long sound signal once every minute and a
half.
How to clean up the smoke chamber
Batteries installed in the detector ensure up to 4 years of autonomous operation. If the batteries
are discharged, the security system will send the respective notifications and the detector will
activate a sound signal once every 90 seconds.
if the main batteries are low - a single short signal;
if the backup battery is low - two short signals;
if all the batteries are low - three short signals.
Tech Specs
Smoke-sensitive element
Photoelectric sensor
Temperature sensitive element
Thermocouple
Sound notification volume
85 dB at a distance of 3 m
Alarm threshold at the
temperature
60°С
Tamper protection
Yes
Frequency band
868.0 – 868.6 MHz or 868.7 – 869.2 MHz depending on the region of
sale
Maximum RF output power
Up to 20 mW