TG drives TGA-24-9/20 Скачать руководство пользователя страница 6

11 

 

Connection to stepper-motor controller 
(X2)   
This interface can be used to connect the 
servoamplifier to a stepper-motor controller 
with 5V signal level. The value of R 
according to line impedance: 150

 – 1k

Interface for encoder input (X2) 
This interface can be used to operate 
the servoamplifier as a slave, 
mastered by an encoder with RS422 
signals level in gearing mode or by 
another servoamplifier (electronic 
gearing)

 

 

 
 

 
 
 

 
 

Interface for encoder simulation 
(X2) 
This interface can be used to output 
incremental position value (RS422 
signals level) in all of the operation 
modes as feedback for the control 
system or as setpoint position in 
Master-Slave operation. 
 

 
 
 
 

 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

TG Drives, s.r.o. 
Jeneweinova 37 
617 00 Brno 
Czech republic 

www.tgdrives.com 
[email protected] 
phone: 00420 545 234 935 
fax:     

 

00420 545 234 735 

Содержание TGA-24-9/20

Страница 1: ...anual Edition 06 2012 servotechnics 2 Type description TGA 24 9 20 standard version TGA 24 9 20 O1 optional communication connector X1 8 pin TGA 24 9 20 O3 optional supply voltage 48VDC TGA 24 9 20 O4 analog input 10V TGA 24 9 20 O8 lite version design ...

Страница 2: ...tion means that you will be responsible for the performance of new measurements to ensure that the regulatory requirements are met Prescribed use of the servoamplifier The servoamplifiers are components which are built into electrical equipment or machines and can only be used as integral components of such equipment The servoamplifiers TGA 24 is only intended to drive with specific brushless sync...

Страница 3: ...5 Instalation Dimensions Material 2 or 4 screws M4 6 Interfaces description ...

Страница 4: ...s should be as short as possible 8 Resolver cable connection X7 The resolver cable connection for TGT1 TGT2 TGT3 TGH2 TGH3 servomotors with the cable glands The resolver cable connection for TGT1 TGT2 TGT3 TGH2 TGH3 servomotors with the round connectors The resolver cable connection for TGH0 servomotors with the flying leads ...

Страница 5: ...lifier while the supply to the equipment is switched off via a normal commercial 3 core null modem cable to a serial interface on the PC see the diagrams below CAN BUS interface To meet ISO11898 you should use a bus cable with a characteristic impedance of 120 Ω The maximum usable cable length for reliable communication decreases with increasing transmission speed Cable length depending on the tra...

Страница 6: ...as a slave mastered by an encoder with RS422 signals level in gearing mode or by another servoamplifier electronic gearing Interface for encoder simulation X2 This interface can be used to output incremental position value RS422 signals level in all of the operation modes as feedback for the control system or as setpoint position in Master Slave operation TG Drives s r o Jeneweinova 37 617 00 Brno...

Отзывы: