TG drives TGA-24-9/20 Скачать руководство пользователя страница 2

 

Safety instructions 

 

Read this documentation before carying out instalation. Incorrect handling of the 
servoamplifier can lead to personal injury or material damage.  

 

The servoamplifier contain electrostatically sensitive components which may be 
damaged by incorrect handling. Ground yourself before touching the 
servoamplifier. 

 

Do not open the units. Keep all cover and switchgear cabinet doors closed during 
operation.  

 

Servoamplifiers may have hot cooling surfaces during operation.  

 

Never undo the electrical connections to the servoamplifier while it is live. There 
is danger of electric arcing with damage to contacts. 

European directives and standards 

Servoamplifiers are components, which are intended to be incorporated into electrical 
plants and machines for industrial use.  
When the servoamplifiers are built into machines or plants, the intended operation of 
the amplifier is forbidden until it has been established that the machine or plant 
fulfills the requirements of the EC Directive on Machines 98/37/EC and the EC 
Directive on EMC (89/336/EEC).  
The manufacturer of of the machine or plant is responsible for ensuring that they 
meet the limits which are required by the EMC regulations.  

CE – conformance 

Conformance with the EC Directive on EMC 89/336/EEC is mandatory for the 
supply of servoamplifiers within the European Cummunity. 
The servoamplifiers TGA-24 have been tested by an authorized testing laboratory in a 
defined configuration with the system components which are described in this 
documentation. Any divergence from the configuration anf installation described in 
this documentation means that you will be responsible for the performance of new 
measurements to ensure that the regulatory requirements are met. 

Prescribed use of the servoamplifier 

The servoamplifiers are components which are built into electrical equipment or 
machines, and can only be used as integral components of such equipment. 
The servoamplifiers TGA-24 is only intended to drive with specific brushless 
synchronous servomotors, with closed-loop control of torque, speed and/or position.  
The servoamplifiers may only be operated in a closed switchgear cabinet, taking into 
account the ambient conditions in technical specification. Use only copper wire. Wire 
size may be determined from EN60204.  
We only guarantee the conformance of the servoamplifiers with the standards for 
industrial areas, if the components (motors, cables, amplifiers etc) are delivered by 
TG Drives s.r.o. 

 

 

 

Technical data 

 

Parameters 

Unit  Data 

Rated supply voltage 

V = 

24 (15 - 42) 

option O3: 48 

Rated installed load for S1 operation 

230 

Rated output current 

A

rms 

Peak output current (max. ca 5 s) 

A

rms 

18,5 

Overvoltage protection treshold (transil) 

47 

Dissipation at rated load 

20 

Fusing 
Supply 24 VDC       – internal 
                                 – external 

– 

T 10 A 

– 

C 8 A 

Inputs / outputs 

Analog input, resolution 12 bit 

Input resistance  

0 - 5  

option O4: ±10 

k

 

15 

Digital inputs with adjustable function 24 VDC 
             

qty 

low 0 .. 5 / high 7 .. 30 

mA 

Digital outputs with adjustable function,  
24 VDC, PNP 

qty 

max. 42 

mA 

25 

Counter inputs for IRC or stepper-motor signals  

– 

5V (RS422) 

Connectors 
Control signals 

– 

Interhart 3.81, 1.5mm

2

 

Power 

– 

Interhart 5.08, 2.5mm

2

 

Resolver input 

– 

Interhart 3.81, 1.5mm

2

 

Communication 

– 

SubD 9-pole plug 

option O1

 8-pole Interhart 3.81 

Mechanical 
Weight 

kg 

0.6 

RoDimensions without connectors 

mm 

157 

×

 86 

×

 40 

Environment 
Operating temperature  

°C 

0 - 40 

Relative humidity 

 max. 85 

 

 

 

 

Содержание TGA-24-9/20

Страница 1: ...anual Edition 06 2012 servotechnics 2 Type description TGA 24 9 20 standard version TGA 24 9 20 O1 optional communication connector X1 8 pin TGA 24 9 20 O3 optional supply voltage 48VDC TGA 24 9 20 O4 analog input 10V TGA 24 9 20 O8 lite version design ...

Страница 2: ...tion means that you will be responsible for the performance of new measurements to ensure that the regulatory requirements are met Prescribed use of the servoamplifier The servoamplifiers are components which are built into electrical equipment or machines and can only be used as integral components of such equipment The servoamplifiers TGA 24 is only intended to drive with specific brushless sync...

Страница 3: ...5 Instalation Dimensions Material 2 or 4 screws M4 6 Interfaces description ...

Страница 4: ...s should be as short as possible 8 Resolver cable connection X7 The resolver cable connection for TGT1 TGT2 TGT3 TGH2 TGH3 servomotors with the cable glands The resolver cable connection for TGT1 TGT2 TGT3 TGH2 TGH3 servomotors with the round connectors The resolver cable connection for TGH0 servomotors with the flying leads ...

Страница 5: ...lifier while the supply to the equipment is switched off via a normal commercial 3 core null modem cable to a serial interface on the PC see the diagrams below CAN BUS interface To meet ISO11898 you should use a bus cable with a characteristic impedance of 120 Ω The maximum usable cable length for reliable communication decreases with increasing transmission speed Cable length depending on the tra...

Страница 6: ...as a slave mastered by an encoder with RS422 signals level in gearing mode or by another servoamplifier electronic gearing Interface for encoder simulation X2 This interface can be used to output incremental position value RS422 signals level in all of the operation modes as feedback for the control system or as setpoint position in Master Slave operation TG Drives s r o Jeneweinova 37 617 00 Brno...

Отзывы: