6.2.1.5 JOYSTICK OPERATOR STATION (Y4E-JS)
This operator station is installed in a protected location and allows the monitor to be controlled by a joystick.
6.2.1.6 TOGGLE SWITCH OPERATOR STATION (Y4E-TS)
This operator station allows the monitor to be operated by three toggle switches.
27
6.2.3 STOW FEATURE
The STOW position needs to be programmed during installation. The monitor needs to “find” two (2) hard stops, one for each axis,
before the monitor can move to the STOW position. When programming, the first two commands teach the monitor where to find the
hard stops. This guarantees that the position is accurate. From that point, the programmer can program the move to the final STOW
position.
During normal operation, each time the STOW button is pressed, the monitor moves the nozzle to the full straight stream position,
moves to each programmed hard stop, and then moves to the STOW position. While the monitor is performing the STOW feature,
pressing any button will stop the monitor.
6.2.2 MASTER OVERRIDE FEATURE (DIP #1)
Any operator station with a communication board can be reconfigured with the master override feature. These stations include the Y4E-
RP, Y4E-CT-30, Y4E-CT-100, Y4E-TS, Y4E-JS or any inputs connected to an Y4E-COMM. To enable the master override feature on an
operator station, follow these steps:
1. Remove lid from enclosure.
2. Locate DIP switches on communication board.
3. Slide DIP switch #1 to the ON position.
4. Replace lid. Verify rubber seal is clean and undamaged. Verify that no wires are caught between lid and box.
Figure 6.2.2
Master Override Setup
ON
CTS
12
3
4
6.2.3.1 PROGRAMMING
STOW programming must be initiated within 1 minute of applying power to monitor. After 1 minute, programming access is blocked.
Power must then be cycled to reset 1 minute timer.
Press and hold STOW button (~10 seconds) until light blinks. Release button. Light will continue to blink while in program mode.
Press
release LEFT/RIGHT or UP/DOWN button of axis that will move to first hard stop. Light will blink rapidly when hard stop is
reached.
Press
release LEFT/RIGHT or UP/DOWN button of axis that will move to second hard stop. Light will blink rapidly when hard stop is
reached.
Use LEFT/RIGHT or UP/DOWN buttons to move monitor to first point of stow routine, press
release STOW button. Light will blink
rapidly to acknowledge position.
Repeat until pattern is complete (up to 10 points).
Press
hold STOW button until light turns off. Release button.
FIRST AXIS TO MOVE:
SECOND AXIS TO MOVE:
MOVE TO STOW POSITION:
and
and
and
and