*SMART STREAM
1)
2)
NOZZLE STOPS AT FULL FOG
PRESS AGAIN FOR FLUSH
®
TASK FORCE TIPS
FIRE FIGHTING EQUIPMENT
Where New Ideas Flow™ • 800-348-2686 • www.tft.com
Y5336
OSCILLATE PATTERN PROGRAMMING:
1)
2)
3)
4)
5)
Move monitor to starting point of pattern.
Press & hold OSC button until LED blinks. LED will continue to blink in program mode.
Move monitor to 2nd point, press OSC button. LED will blink rapidly to acknowledge position.
Repeat until pattern is complete.
Press & hold OSC button until LED turns off.
NOTE: PATTERN WILL BE CLEARED UPON POWER LOSS.
TO OSCILLATE:
Pattern must be programmed first.)
Press & release OSC button.
(
TO STOW:
Press & release STOW button.
(Programmable, refer to manual.)
STRAIGHT
STREAM
FOG
THEN FLUSH*
5.4 JOYSTICK MONITOR OPERATOR STATION (Y4E-JS)
5.4.1 MOUNTING
This operator station allows the monitor to be controlled by a joystick. The installer will need to mount the joystick control and connect the
cable to a receptacle or terminal box with power and communication connections. The joystick control needs to be mounted in a
weatherproof location, for example, inside the cab of the truck.
Select proper weatherproof operating location. Joystick control box requires 4 ¾” x 4 ¾” x 4” (121mm x 121mm x 102mm) of space and
the joystick extends 6 ¼” (159mm) above the control box. Threaded mounting holes are located on the bottom of the joystick control box.
Refer to Figure 5.4.1.1 for hole layout.
Fig 5.4.1.1
Joystick Operator Station Hole Dimensions
5.3.3 TEACHING ID CODE:
Every monitor has a unique ID code that must be “taught or transferred” to the handheld unit. This unique ID code allows multiple
monitors to be used in one location without interference. Perform the following procedure to teach the handheld unit.
-Press POWER button to turn on electronics.
-Press and hold both LEFT & RIGHT buttons for 5 seconds.
-Continue to press LEFT & RIGHT buttons and then press UP button for 2 seconds.
-Release buttons. OSC & STOW lights will flash rapidly to indicate that the unit is in teach mode.
On Handheld Unit:
On Monitor Control Box:
-Apply power to monitor.
-Press and hold both LEFT & RIGHT buttons for 5 seconds.
-Continue to press LEFT & RIGHT buttons and then press UP button for 2 seconds.
-Release buttons. OSC & STOW lights will flash rapidly to indicate that the unit is in teach mode.
-OSC & STOW lights on handheld unit will stop flashing after ID code is transferred.
-Press DOWN button on monitor control box to exit teach mode.
-Cycle power off and back on to monitor.
NOTE: When the operator station is purchased at the same time as RC monitor,
handheld unit will be pre-taught at factory.
5.3.4 CHANGING BATTERIES:
Four (AA) Batteries, Lithium Recommended
-Remove two (2) screws on backside of handheld unit and slide bottom half of rubber bumper off enclosure.
-Replace batteries verifying that polarity is correct.
-Replace rubber bumper and retaining screws.
CAUTION
Properly dispose of old batteries. Do not puncture, incinerate, or disassemble batteries.
Do not mix battery types.
5.4.2 ELECTRICAL WIRING
This operator station will have a factory installed 4-conductor cable with a plug on the end. The installer will need to mount the mating
receptacle (YE-RECEP-4) in a suitable location. Refer to Sections 5.2.2 and 5.2.3 for proper receptacle installation and wiring.
When a Valve Kit is used (YE-VK-PH), the receptacle is provided on the valve interface enclosure and is pre-wired to the control system.
NOTE: THE JOYSTICK TRIGGER IS FACTORY WIRED TO THE AUX2 CONNECTION. FOR TRIGGER-CONTROLLED VALVE
OPERATION, THE VALVE INTERFACE RELAYS MUST BE CONFIGURED FOR AUX2.
Fig 5.4.1.2
Joystick Instruction Label
Install joystick instruction label nearby for quick operation reference.
3-5/16"
(84mm)
4"
(102mm)
MOUNT ENCLOSURE
WITH (2) 1/4-20 FASTENERS.
TIGHTEN SECURELY.