©Copyright Task Force Tips LLC 2004-2018
LIY-050 January 23, 2018 Rev13
17
4.2.3 ELEVATION TRAVEL STOPS
The range of elevation travel for the Typhoon Monitor is 45 degrees past vertical to 45 degrees below horizontal. The elevation range
may be limited by installing the supplied stop bolts and adjustment disks at the locations shown is fi gures 4.2.3A and 4.2.3B. Consult
factory for other ranges. The fi gures include installation notes.
30° WITH STOP BOLT
10° LESS WITH EVERY ADJUSTMENT
DISK (Y3146) INSTALLED ABOVE
THE STOP BOLT(Y4145)
45°
WITHOUT
STOP BOLT
45° WITH OR WITHOUT
STOP BOLT
10° LESS WITH EVERY
ADJUSTMENT DISK (Y3146)
INSTALLED BELOW
THE STOP BOLT(Y4145)
Fig 4.2.3A
Elevation Travel Limits
Remove set screw and install Stop Bolt
to obtain desired travel limits.
SET SCREW
VT37-24SS250
ADJUSTMENT DISK
Y3146 (INSTALL
ABOVE STOP BOLT)
STOP BOLT
Y4145
Fig 4.2.3B
Elevation Travel Stop Locations