background image

©Copyright Task Force Tips LLC 2021

14

LIX-575 June 24, 2021 Rev00

7.0 EXTEND-A-GUN VP INSTALLATION OVERVIEW

Section 7.0 is an overview for planning the equipment layout, followed by detailed assembly instructions in Section 8.0. This device is

received in 3 subassemblies: the telescoping waterway, the waterway valve, and the pneumatic cylinder. These subassemblies allow

assembly through the deck of the truck and selection of the appropriate orientations for the valve inlet and driveshaft. The telescoping

waterway must be oriented vertically with the outlet facing upwards.

Figure 7.0

7.1 POSITION INDICATING HANDWHEEL (NOT INCLUDED)

The waterway  valve  in  this  device  will  be  hidden  within  the  vehicle,  and  thus

requires  a  position  indicating  handwheel  to  show  the  valve  position  from  the

pump panel. The position indicating handwheel must be 9 turns from closed to

open,  with  a  counterclockwise  opening  direction  per  NFPA  1901.

A 4” handwheel is recommended due to the low operating torque of this valve

design. The driveshaft for the valve handwheel is intended to be extended with

½” rod and universal joints that are compatible with the driveshaft geometry, see

Figure  7.1.  Trident  Emergency  Products  item  19.409  is  a  suitable  handwheel

that includes 2 universal joints.

7.2 DECK MONITOR UP/DOWN TOGGLE SWITCH (NOT INCLUDED)

The telescoping waterway is intended to be driven by a single pole, single throw switch chosen by the installer, which will toggle the input

of  an  electrical  relay.  This  toggle  switch  will  only  function  when  the  valve  is  closed  and  should  be  mounted  adjacent  to  the  valve

handwheel.

7.3 PNEUMATIC REQUIREMENTS

The telescoping waterway of this device is driven up and down by a pneumatic cylinder. It is intended to be installed on vehicles that

include an air compressor to supply the air brake system. To protect the air brake system as well as this device, the system must include

the following:

1. An air compressor governor switch calibrated to a maximum of 130 psi

2. A safety relief valve calibrated to a maximum of 150 psi

In addition, the system must include the following per NFPA 1901, 2016 edition:

3. A pressure protection valve (PPV) calibrated to a minimum of 80 psi, installed between the air supply tank and the pneumatic

directional control valve of the Extend-A-Gun VP

4. An air dryer installed between the compressor and wet air tank

5. An automatic moisture ejector connected to the bottom of the wet air tank

NOTICE

This device includes a smaller air pressure relief valve, with a capacity of 130 scfm. This relief valve 

cannot relieve overall system pressure and does not take the place of the mandatory air pressure 

regulator and safety relief valve that are required by the air brake system. This relief valve is only 

intended to relieve unintended overloads exceeding 150 psi in the extend circuit of the air cylinder 

itself. 

TELESCOPING WATERWAY

PNEUMATIC CYLINDER

WATERWAY VALVE

  .50" 

  .25" 

 .50" 

 1.05" 

Figure 7.1

Содержание Extend-A-Gun VP

Страница 1: ...ice without understanding the manual and receiving proper training is a misuse of this equipment Obtain safety information at tft com serial number This equipment is intended for use by trained and qu...

Страница 2: ...IBILITY to know that you have been properly trained in Fire ghting and or Emergency Response and in the use precautions and care of any equipment you may be called upon to use 4 IT IS YOUR RESPONSIBIL...

Страница 3: ...PLATE BRACKET INSTALLATION 7 0 EXTEND A GUN VP INSTALLATION OVERVIEW 7 1 POSITION INDICATING HANDWHEEL NOT INCLUDED 7 2 DECK MONITOR UP DOWN TOGGLE SWITCH NOT INCLUDED 7 3 PNEUMATIC REQUIREMENTS 7 4...

Страница 4: ...g a nozzle is very powerful and capable of causing injury and property damage Make sure the nozzle is securely attached and pointing in a safe direction before water is turned on Do not direct water s...

Страница 5: ...the equipment may be shortened due to the effects of corrosion and is not covered under warranty MECHANICAL Waterway Size 3 76mm Safe Operating Range for Monitor Outlet Maximum flow rates at specified...

Страница 6: ...NUMBER VALVE INDICATOR REED SWITCH STOWED INDICATOR REED SWITCH EXTENDED INDICATOR MANUAL OVERIDE PIN REED SWITCH VALVE INDICATOR EXTEND AIR VALVE CONNECTION RETRACT AIR VALVE CONNECTION 1 4 QUICK CO...

Страница 7: ...pyright Task Force Tips LLC 2021 7 LIX 575 June 24 2021 Rev00 3 4 OVERALL DIMENSIONS Figure 3 4 5 75 7 25 02817 1 036 6 2 57 25 63 1 67 1 0 1 520 723 03 72 723 2 17 5 2 6 1 7 7 5 6 7 1 8 81 76 6 2 1 1...

Страница 8: ...sed position 3 Remove the manual override pin from the STORED position 4 While holding the monitor in the fully raised position insert the pin through the center hole of the bracket and into a small p...

Страница 9: ...all fasteners to specified values NAME _______________________________________ DATE ______ _____ __________ 1 Determine the value of H2 using the table below 2 Determine the value of D1 for you instal...

Страница 10: ...ith the proposed installation 6A Calculate the moment arm about the lower mounting bracket L by adding together D1 D2 D3 and H2 L D1 D2 D3 H2 6B Determine R using the same side load chart referenced i...

Страница 11: ...10 8 16 0 2 0 1 0 25 4 11 3 16 0 2 5 31 4 14 2 14 5 2 0 24 4 10 8 15 0 2 0 26 4 11 7 15 0 3 0 25 4 10 8 14 0 3 0 27 4 12 2 14 0 D1 D2 Height D3 Min D3 Max 4 0 26 4 10 8 13 0 4 0 28 4 12 6 13 0 8 0 1 0...

Страница 12: ...square steel tube with two U bolts to be used as the upper bracket and a saddle bracket similar to a heavy duty muffler clamp for the lower bracket Both brackets must be used This kit is designed for...

Страница 13: ...Bracket Welding Diagram see section 6 3 2 1 Both brackets must be used To minimize stress the brackets should be as far apart as possible when clamped to the Extend A Gun VP tube Refer to the SIDE LO...

Страница 14: ...by a single pole single throw switch chosen by the installer which will toggle the input of an electrical relay This toggle switch will only function when the valve is closed and should be mounted ad...

Страница 15: ...6 0 it is critical to verify adequate clearance for the deck plate and pneumatic cylinder It is also critical to verify clearance for the swing radius of the valve which must be spun onto a threaded c...

Страница 16: ...9 noted has the gearbox facing rearward when the inlet is on the left side 4 As viewed from the outlet end of the device the pneumatic cylinder must always be mounted approximately 180 from the valve...

Страница 17: ...erway through the clearance hole keeping the reed switch wiring above the deck 5 Install the U bolts in the mounting brackets and torque the nuts per Section 6 0 which varies by bracket type 8 2 VALVE...

Страница 18: ...ting screws using a 5 16 hex driver then rotate the gearbox until the REFERENCE ARROW points towards the letter from the table If resistance is encountered rotate the opposite direction instead to avo...

Страница 19: ...the two notches on the bottom of the deck plate While holding the cylinder up against the deck plate install the band clamp spacer as low as practical between the telescoping waterway and the pneumati...

Страница 20: ...ll magnetic switches ternimate in Deutsch connectors with labels Refer to the wiring diagram for proper installation 4 There is also an electrically actuated pneumatic directional control valve that r...

Страница 21: ...Copyright Task Force Tips LLC 2021 21 LIX 575 June 24 2021 Rev00 8 5 1 WIRING DIAGRAM Figure 8 5 1 8 5 2 PLUG REFERENCE Figure 8 5 2...

Страница 22: ...r complete installation perform the following actions in order NOTICE D Damage to equipment may occur when operated with low clearance Always ensure there is adequate clearance before attempting to ra...

Страница 23: ...unted to an Extend A Gun with a PL outlet with the addition of an XFF CPL Companion Flange Kit 9 1 TWO PIECE CLAMP ROTATIONAL LOCK INSTALLATION FOR RL OUTLETS Task Force Tips monitors with RL inlet ar...

Страница 24: ...MARK EXTEND A GUN OUTLET STEP 5 Unscrew monitor base from Extend A Gun outlet until Straight Ahead Reference Mark is facing desired direction Monitor may be unscrewed up to one full rotation from bott...

Страница 25: ...r or replacement TFT may elect to refund the purchase price of the equipment less reasonable depreciation in complete discharge of its obligations under this limited warranty If TFT makes this electio...

Страница 26: ...adapter This inlet adapter shown in Figure 3 3 bottom inlet configuration and Figure 8 2A side inlet configuration also serves as the valve seat retainer 4 Near the A port marking on the opposite side...

Страница 27: ...raise If not verify 80 psi then follow the pneumatic calibration instructions 7 Per Figure 8 5 1 with switch in UP position verify continuity from terminal 85 to ground then verify 10 volts from grou...

Страница 28: ...com serial number 15 0 OPERATION AND INSPECTION CHECKLIST BEFORE EACH USE the Extend A Gun VP must be inspected to this checklist 1 There is no obvious damage such as missing broken or loose parts da...

Отзывы: