background image

 

25 

DCF RADIO CONTROLLED TIME 

The time base for the radio controlled time is a Cesium 
Atomic Clock operated by the Physikalisch Technische 
Bundesanstalt Braunschweig which has a time deviation of 
less than one second in one million years. The time is 
coded and transmitted from Mainflingen near Frankfurt via 
frequency signal DCF-77 (77.5 kHz) and has a 
transmitting range of approximately 1,500 km. Your radio-
controlled weather station receives this signal and 
converts it to show the precise time in summer or 
wintertime. 
The quality of the reception depends greatly on the 
geographic location. In normal cases, there should be no 
reception problems within a 1,500 km radius of Frankfurt.  

 

DCF reception is done twice daily at 02:00 and 03:00 am. 
If the reception is not successful at 03:00 am, then the 
next reception takes place the next hour and so on until 
06:00am, or until the reception is successful. If the 
reception is not successful at 06:00 am, then the next 
attempt will take place the next day at 02:00 am. 

 

If the tower icon flashes, but does not set the time or the 
DCF tower does not appear at all, then please take note of 
the following: 

• 

Recommended distance to any interfering sources 
like computer monitors or TV sets is a minimum of 
1.5 - 2 meters. 

• 

Within ferro-concrete rooms (basements, 
superstructures), the received signal is naturally 
weakened. In extreme cases, please place the unit 
close to a window and/ or point its front or back 
towards the Frankfurt transmitter. 

• 

During nighttime, the atmospheric disturbances are 
usually less severe and reception is possible in most 
cases. A single daily reception is adequate to keep 
the accuracy deviation below 1 second.

 

 

 
 
 
 
 

Содержание Xeno

Страница 1: ...iable for any damage occurring as a result of not following these instructions Please take particular note of the safety advice Please look after this manual for future reference SCOPE OF SUPPLY Weather station basic unit Outdoor transmitter Instruction manual FIELD OF OPERATION AND ALL OF THE BENEFITS OF YOUR NEW WEATHER STATION AT A GLANCE DCF Radio controlled time with manual setting option Tim...

Страница 2: ...atteries must not be thrown into the fire short circuited taken apart or recharged Risk of explosion Batteries contain harmful acids Low batteries should be changed as soon as possible to prevent damage caused by a leaking battery Never use a combination of old and new batteries together or batteries of different types Wear chemical resistant protective gloves and glasses when handling leaked batt...

Страница 3: ...tely display the outdoor temperature and humidity readings on LCD Wall mounting case Mounting at a sheltered place Avoid direct rain and sunshine TO INSTALL AND REPLACE BATTERIES IN THE THERMO HYGRO TRANSMITTER The outdoor thermo hygro transmitter uses 2 x AAA IEC LR3 1 5V batteries To install and replace the batteries please follow the steps below Battery compartment Hanging hole ...

Страница 4: ...nd lift up to remove the cover 2 Insert batteries observing the correct polarity see marking 3 Replace compartment cover Battery replacement Replace the batteries when the battery symbol of the weather station appears on the upper display When the batteries of the transmitter are used up the low battery icon appears next to the outdoor temperature display Note In the event of changing batteries in...

Страница 5: ...temperature and humidity data should then be displayed on the weather station If this does not happen after 2 minutes the batteries will need to be removed from both units and reset from step 1 4 In order to ensure sufficient 868 MHz transmission however the distance between the weather station and the transmitter should not be more than 100 meters see notes on Positioning and 868 MHz Reception No...

Страница 6: ... 03 00 am If the reception is not successful at 03 00 am then the next reception takes place the next hour and so on until 06 00am or until the reception is successful If the reception is not successful at 06 00 am then the next attempt will take place the next day at 02 00 am If the tower icon flashes but does not set the time or the DCF tower does not appear at all then please take note of the f...

Страница 7: ...unction keys SET key Press and hold the key to enter manual setting modes time zone manual time setting calendar time reception ON OFF key Increase change toggle all values in manual set mode MIN MAX key Press shortly to toggle between indoor and outdoor MAX MIN temperature and current temperature ...

Страница 8: ... reception was successful icon on or not icon off MANUAL SETTINGS The following manual settings can be changed by pressing and holding the SET key Time zone setting Manual time setting Calendar setting Time reception ON OFF setting Moon phase icon Weather tendency indicator Calendar Indoor relative humidity in RH Time reception icon for DCF time Indoor temperature in ºC Weather forecast icon Outdo...

Страница 9: ...ly set The clock will then work as a normal quartz clock 1 The hour digit will start flashing 2 Use the key to set the hour 3 Press again the SET key to set the minutes The minute digits start flashing 4 Use the key to set the minutes 5 Confirm with the SET key and enter the Calendar setting Note The unit will still try and receive the signal despite it being manually set When it does receive the ...

Страница 10: ...et the month 5 Press the SET key again to confirm and to enter the date setting mode The date starts flashing 6 Use the key to set the date 7 Confirm all calendar settings with the SET key and enter the Time reception ON OFF setting TIME RECEPTION ON OFF SETTING In areas where reception of the DCF time is not possible the DCF time reception function can be turned OFF The clock will then work as a ...

Страница 11: ...e will indicate the current moon phase WEATHER FORECAST AND WEATHER TENDENCY WEATHER FORECASTING ICONS The weather icons in the second section of LCD can be displayed in any of the following combinations Sunny Cloudy with sunny intervals Rainy For every sudden or significant change in the air pressure the weather icons will update accordingly to represent the change in weather If the icons do not ...

Страница 12: ...tation has been designed for use In areas that experience sudden changes in weather for example from sunny to rain the weather station will be more accurate compared to use in areas where the weather is stagnant most of the time for example mostly sunny If the weather station is moved to another location significantly higher or lower than its initial standing point for example from the ground floo...

Страница 13: ...ed on the fourth section of the LCD OUTDOOR TEMPERATURE HUMIDITY DATA The last LCD section shows the outdoor temperature and humidity and the reception indicator TOGGLING AND RESETTING THE MIN MAX DATA TO VIEW THE MIN MAX DATA Press the MIN MAX key several times to view the MIN MAX indoor temperature and MIN MAX outdoor temperature sequentially TO RESET THE MIN MAX DATA Press and hold MIN MAX key ...

Страница 14: ...nt correct signal transmission or reception Neighbors using electrical devices operating on the 868MHz signal frequency can also cause interference Note When the 868MHz signal is received correctly do not re open the battery cover of either the transmitter or weather station as the batteries may spring free from the contacts and force a false reset Should this happen accidentally then reset all un...

Страница 15: ...d direct rain and sunshine The thermo hygro transmitter can be placed onto any flat surface or wall mount using the bracket which doubles as a stand or wall mount base To wall mount 1 Secure the bracket onto a desired wall using the screws and plastic anchors 2 Clip the transmitter onto the bracket Note Before permanently fixing the thermo hygro to the wall base place all units in the desired loca...

Страница 16: ...d weather station as per the manual Choose another place for the transmitter and or the weather station Reduce the distance between the transmitter and the weather station Check if there is any source of interference No DCF reception Time reception setting ON Choose another place for the weather station Manual time setting Wait for attempted reception during the night Incorrect display Change batt...

Страница 17: ...or 9 9ºC to 59 9ºC with 0 1 C resolution OF L displayed if outside this range Outdoor 39 9ºC to 59 9ºC with 0 1 C resolution OF L displayed if outside this range Indoor humidity range 20 to 95 with 1 resolution Display if temperature is OL F display 19 if 20 and 96 if 95 Outdoor humidity range 1 to 99 with 1 resolution Display if outside temperature is OF L display 1 if 1 and 99 if 99 Data checkin...

Страница 18: ...e correct at the time of going to print and may change without prior notice DECLARATION OF CONFORMITY Herewith we declare that this wireless transmission device does comply with the essentials requirements of R TTE Directive 1999 5 EC A copy of the signed and dated Declaration of Conformity is available on request via info tfa dostmann de www tfa dostmann de 06 11 ...

Отзывы: