2.
With the tester in place remove the lock out, press the reset button and simulate a manual seal.
TO
AVOID INJURY DO NOT HOLD THE TESTER IN PLACE WITH YOUR HANDS OR
FINGERS DURING THE SEAL CYCLE.
When the machine attempts to cycle, the seal head
should instantly open upon striking the safety tester and the machine should go into an e-stop mode. If
the jaws do not instantly open then the film clamps are
not
set properly and need to be adjusted until
the seal head instantly retracts. This protects the operator and the product. Repeat this procedure on the
side seal jaw (see illustration #3).
(Illustration #4)
(Illustration #5)
3.
With the tester removed, simulate a manual seal. If the seal head closes and stays closed for the
designated seal time (see illustrations 4 & 5) then the film clamps are set correctly.
4.
This procedure should be repeated in 6” intervals on both cross and side seal film clamps.