EK622PLU Battery-powered Crimping Tool
Greenlee / A Textron Company
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
10
Problem
Possible Cause
Probable Remedy
Tool is inoperative.
Dirt, contaminants, etc., in ram area
of tool.
Clean tool.
Tool components worn or damaged.
Return tool to a Greenlee Utility
Authorized Service Center.
Motor is inoperative.
Low or uncharged battery.
Try known charged battery. Inoperative
battery may be discharged or may have
reached life expectancy.
Broken switch components.
Return tool to a Greenlee Utility
Authorized Service Center.
Motor runs but tool will not
complete a cycle.
Oil level low.
Return tool to a Greenlee Utility
Authorized Service Center.
Air in hydraulic system.
Pull trigger and hold retract button
simultaneously. Run for approximately
10 seconds, and then attempt to
crimp. If unsuccessful, return tool to
a Greenlee Utility Authorized Service
Center.
Cold oil.
Pull trigger and hold retract button
simultaneously to warm oil. Store tool
in warm area.
Dies stop during operation.
Oil level low.
Return tool to a Greenlee Utility
Authorized Service Center.
Air in hydraulic system.
Pull trigger and hold retract button
simultaneously. Hold for approximately
10 seconds.
LED glows for 20 seconds.
Battery charge low.
Charge or replace battery.
Tool loses oil.
Damaged internal seal.
Return tool to a Greenlee Utility
Authorized Service Center.
Note: For Warranty Service or Repair, contact Greenlee customer service at 800-435-0786.
Troubleshooting
Before You Begin
1. Make sure that the battery is charged. Recheck
the battery after several minutes to make sure the
battery is holding its charge.
2. Use a
nonflammable
contact cleaner or pencil
eraser to clean the electrical contacts on the battery
and tool.
3. Reinstall the battery and check the tool again.