LP6 Hydraulic Crimping Tool
Greenlee / A Textron Company
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
7
Specifications
LP6 Crimping Tool
Type of Hydraulic System: Open-center
or closed-center
Hydraulic Ports:
Pressure (supply): 3/4-16 UNF SAE O-ring Boss
Tank (return): 3/4-16 UNF SAE O-ring Boss
Noise Levels
L
WA
(Sound Power Level): 55.5 dB
L
pCpeak
(Peak Emission Sound Pressure Level):
68.8 dB
Vibration: 3.15 ms
2
Crimping Force: 53 kN (6 tons)
Length:
With Couplers:
597 mm (23.50")
Without Couplers: 527 mm (20.75")
Width: 76 mm (3.00")
Depth: 165 mm (6.50")
Mass/Weight: 4.2 kg (9.25 lb)
Hydraulic Power Source
Do not exceed the following hydraulic power source
maximums:
• Hydraulic flow: 34.1 l/min (9 gpm).
• Pressure relief setting: 172 bar (2500 psi).
• Back pressure: 13.8 bar (200 psi)
Failure to observe this warning could result in severe
injury or death.
Type of Hydraulic System: Open-center
or closed-center
Flow:
Minimum: 11.4 l/min (3 gpm)
Recommended: 22.7 l/min (6 gpm)
Maximum: 34.1 l/min (9 gpm)
Pressure Relief Setting:
Minimum: 103 bar (1500 psi)
Maximum: 172 bar (2500 psi)
Filtration: 10 micron (nominal)
Back Pressure (maximum*): 13.8 bar (200 psi)
* 13.8 bar (200 psi) is the maximum agreed standard back pressure
for the HTMA (Hydraulic Tool Manufacturers Association).
Greenlee Utility tools will operate satisfactorily at this standard.
1. Maximum hydraulic fluid temperature must not
exceed 60 °C (140 °F). A sufficient oil cooling
capacity is needed to limit the hydraulic fluid
temperature.
2. Hydraulic flow must not exceed 34.1 l/min (9 gpm).
Install a flow meter in the return line to measure the
rate of hydraulic flow before using the tool.
3. Pressure relief valve setting must not exceed
172 bar (2500 psi) at your tool’s maximum flow.
Locate the pressure relief valve in the supply circuit
to limit excessive hydraulic pressure to the tool.
Hydraulic Schematic
FILTER
(10 MICRON)
COOLER
RELIEF
VALVE
172 bar
(2500 psi)
CONTROL
VALVE
FLOW METER
T
P
TOOL
RESERVOIR
PUMP
POWER SOURCE
Recommended Hydraulic Fluids
Use any nondetergent, petroleum-based hydraulic
fluid which meets the following specifications or HTMA
specifications.
S.U.S. @:
38 °C (100 °F): 140 to 225
99 °C (210 °F): 40 minimum
Flash Point: 170 °C (340 °F) minimum
Pour Point: –34 °C (–30 °F) minimum