Specifications

HRD44A Rotary Hammer

Type of Hydraulic System .............................Open-center
Hydraulic Pressure Port ................................... 3/8" NPTF
Hydraulic Return Port ...................................... 3/8" NPTF
Mass/Weight ................................................. 20 kg (44 lb)
Length ...................................................644.7 mm (25.4")
Width (across handles) ................................412 mm (16")
Shank Size ................................................... 7/8" x 4-1/4"

Hydraulic Power Source

Do not exceed the following hydraulic power source 

maximums:

Hydraulic flow:  25 l/min (7 gpm)

• 

Pressure relief:  207 bar (3000 psi)

• 

Back pressure:  13.8 bar (200 psi)

• 
Failure to observe this warning could result in severe 

injury or death.

Type of Hydraulic System .............................Open-center
Flow
  Minimum ............................................20 l/min (5 gpm)
  Maximum ...........................................25 l/min (7 gpm)
Filtration ............................................ 10 micron (nominal)
Pressure Relief Setting ........................ 207 bar (3000 psi)
Back Pressure (maximum) .................... 13.8 bar (200 psi)

Maximum hydraulic fluid temperature must not 

• 

exceed 60 °C (140 °F). A sufficient oil cooling capacity 

is needed to limit the hydraulic fluid  temperature.
Hydraulic flow must not exceed 25 l/min (7 gpm). 

• 

Install a flow meter in the return line to measure the 

rate of hydraulic flow before using the tool.
Pressure relief valve setting must not exceed  

• 

207 bar (3000 psi) at your tool’s maximum flow. 

Locate the pressure relief valve in the supply circuit to 

limit excessive hydraulic pressure to the tool.

Hydraulic Schematic

FILTER

(10 micron)

COOLER

RELIEF

VALVE

207 bar

(3000 psi)

CONTROL

VALVE

FLOW METER

T

P

TOOL

RESERVOIR

PUMP

POWER SOURCE

Recommended Hydraulic Fluids

Use any non-detergent, petroleum-based hydraulic 

fluid which meets the following specifications or HTMA 

specifications.
S.U.S. @:
  38 °C (100 °F) ..............................................140 to 225
  99 °C (210 °F) ........................................... 40 minimum
Flash Point ................................170 °C (340 °F) minimum
Pour Point ................................. –34 °C (–30 °F) minimum

Содержание Greenlee HRD44A

Страница 1: ...aulic Rotary Hammer 52046212 REV 2 2009 Greenlee Textron Inc 9 09 Read and understand all of the instructions and safety information in this manual before operating or servicing this tool Register thi...

Страница 2: ...erve all of the safety information provided Purpose of this Manual This manual is intended to familiarize personnel with the safe operation and maintenance procedures for the Greenlee Utility HRD44A R...

Страница 3: ...ult in severe injury or death Do not drill near energized electri cal lines or underground gas lines Contact could cause electrocution or an explosion Failure to observe this warning will result in se...

Страница 4: ...an result in serious injury Failure to observe this warning could result in severe injury or death Serious injury can result if the operator does not maintain control of the tool Wear slip proof glove...

Страница 5: ...the work area when handling starting and operating the tool Nearby personnel can be injured by flying or falling debris or by flying parts in the event of a tool malfunction Hydraulic oil can cause sk...

Страница 6: ...5 Boeing Dr Rockford IL 61109 2988 USA 815 397 7070 6 Identification 1 Handle 2 Accumulator 3 Valve Body 4 Control Lever 5 Cylinder 6 Air Cleaner 7 Gear Housing 8 Front Head 9 Drill Stay 10 Control Kn...

Страница 7: ...207 bar 3000 psi Back Pressure maximum 13 8 bar 200 psi Maximum hydraulic fluid temperature must not exceed 60 C 140 F A sufficient oil cooling capacity is needed to limit the hydraulic fluid temperat...

Страница 8: ...cting Hoses 1 Move the flow lever on the hydraulic power source to the OFF position 2 Stop the hydraulic power source 3 Connect the return hose to the return port on the hydraulic power source and the...

Страница 9: ...ic hoses according to the instructions under Hose Connections Operation 1 Start the hydraulic power source Note Allow the hydraulic power source to run for a few minutes to warm the hydraulic fluid 2...

Страница 10: ...figure below 1 Remove the accumulator cap 2 Attach the charging valve Accessory P N 504 6251 2 to the accumulator surface and hand tighten 3 Cap the hose connection port of the charging valve Close t...

Страница 11: ...nstructions for removing air from the system Incorrect hydraulic fluid viscosity Use hydraulic fluid with the correct viscosity Refer to the Specifications section Tool feels hot Hydraulic fluid level...

Страница 12: ...Company 4455 Boeing Dr Rockford IL 61109 2988 USA 815 397 7070 12 Illustration 31 44 48 32 33 34 64 35 39 38 76 36 57 87 71 40 74 41 73 97 69 96 85 81 83 82 3 84 93 61 1 42 2 65 4 106 66 51 52 5 6 62...

Страница 13: ...ockford IL 61109 2988 USA 815 397 7070 13 Illustration cont d 104 103 28 102 105 92 29 20 21 22 23 92 28 29 91 89 62 7 8 94 62 78 59 72 77 98 45 11 12 68 72 13 46 80 79 99 56 43 95 61 75 10 63 50 70 1...

Страница 14: ...0897 Plug 5 63 O ring 1 64 O ring G65 1 65 O ring G60 1 66 O ring 2 67 O ring 1 68 O ring 1 69 O ring CO0621 1 70 O ring 2 71 O ring 1 72 O ring 3 73 O ring P5 1 74 Backup ring P5 1 75 Pin 1 76 504601...

Страница 15: ...D44A Hydraulic Rotary Hammer Greenlee A Textron Company 4455 Boeing Dr Rockford IL 61109 2988 USA 815 397 7070 15 Accessories UPC No 78 3310 Part No Description 46251 50462512 Accumulator charging val...

Страница 16: ...ax 815 397 1865 Canada 800 435 0786 Fax 800 524 2853 International 1 815 397 7070 Fax 1 815 397 9247 4455 Boeing Drive Rockford IL 61109 2988 USA 815 397 7070 An ISO 9001 Company Greenlee Textron Inc...

Отзывы: