24
Fault Diagnosis
* Pages 12-15 if a swivel head is used instead of a nose assembly.
† Page 15 if a swivel head is used instead of a nose assembly.
Item numbers in bold refer to the general assembly drawing and parts list on pages 20-21.
More than one
Air leak
Tighten joints or replace components
operation of the
Insufficient air pressure
Adjust air pressure to within specification
5
trigger needed to
Lack of lubrication
Lubricate tool at air inlet point
7
place fastener
Worn or broken jaws
Fit new jaws
8-10*
Low oil level or air in oil
Prime tool
22-23
Build up of dirt inside the nose assembly
Service nose assembly
9†
Tool will not grip
Worn or broken jaws
Fit new jaws
8-10*
stem of fastener
Build up of dirt inside the nose assembly
Service nose assembly
8-10*
Loose jaw housing
Tighten against locking ring
8-10*
Weak or broken spring in nose assembly
Fit new spring
8-10*
Incorrect component in nose assembly
Identify and replace
8-10*
Rotary valve incorrectly adjusted
Read ‘Operating Procedure’
7
Jaws will not release
Build up of dirt inside the nose assembly
Service nose assembly
9†
broken stem of
Jaw housing, nose tip or nose casing
fastener
not properly seated
Tighten nose assembly
8-10
Weak or broken spring in nose assembly
Fit new spring
8-10*
Air or oil leak
Tighten joints or replace components
Low oil level or air present in oil
Prime tool
22-23
Cannot feed next
Broken stems jammed inside tool
Empty stem collector
4
fastener
Check jaw spreader is correct
8-10*
Adjust air pressure to within specification
5
Rotary valve incorrectly adjusted
Adjust as in ‘Operating Procedure’
7
Slow cycle
Lack of lubrication
Lubricate tool at air inlet point
5
Low air pressure
Adjust air pressure to within specification
5
Build up of dirt inside the nose assembly
Service nose assembly
9†
Tool fails to operate
No air pressure
Connect and adjust to within specification
5
Damaged trigger valve 41
Replace
20-21
Loose base cover 35
Tighten 20-21
Loose stem collector
Tighten retaining nut 21
20-21
Fastener fails to break Insufficient air pressure
Adjust air pressure to within specification
5
Fastener outside tool capability
Use more powerful Genesis tool.
Contact Textron Fastening Systems
Low oil level or air present in oil
Prime tool
22-23
S Y M P T O M
P O S S I B L E C A U S E
R E M E D Y
PA G E R E F
Other symptoms or failures should be reported to your local TFS authorised distributor or repair centre.
Содержание Genesis G2
Страница 1: ...Instruction Manual Genesis G2 model Hydro Pneumatic Power Tool 2...
Страница 24: ...25 Notes...
Страница 25: ...26 Notes...