14
Typical Measurements and Accuracy
(cont’d)
Ω
Resistance
Measurement
SELECT
Continuity
Check
Resistance
Range
Accuracy
600.0 Ω
± (0.5% + 0.5 Ω)
6.000 kΩ
± (0.5% + 0.005 kΩ)
60.00 kΩ
± (0.5% + 0.05 kΩ)
600.0 kΩ
± (0.8% + 0.5 kΩ)
6.000 MΩ
± (1.2% + 0.005 MΩ)
40.00 MΩ*
± (2.3% + 0.05 MΩ)
* AutoCheck™ maximum range of
10.00 MΩ.
Open Circuit Voltage (typical): 0.45 VDC
Continuity
Tone Threshold: Between 10 Ω and 200 Ω
Response Time: Approximately 32 ms
μF
or
nF
Capacitance
Measurement
Capacitance
Range
Accuracy*
60.00 nF
± (2.0% + 0.05 nF)
600.0 nF
±( 2.0% + 0.5 nF)
6.000 μF
± (2.0% + 0.005 μF)
60.00 μF
± (3.5% + 0.05 μF)
600.0 μF
± (3.5% + 0.5 μF)
2000 μF
± (4.0% + 5 μF)
* For film capacitors (capacitors with
negligible dielectric absorption).
Reverse Bias
Forward Bias
SELECT
Diode
Measurement
Diode Test
Measuring Range: 1.000 V
Accuracy: ± (1.0% + 0.003 V)
Test Current (typical): 0.56 mA
Open Circuit Voltage (typical): < 1.8 VDC