12
Voltage Measurement
Typical Measurements and Accuracy
(cont’d)
AC Voltage VFD
Range
Accuracy at
10 Hz to 20 Hz
Accuracy at
20 Hz to 200 Hz
Accuracy at
200 Hz to 400 Hz*
6.000 V ± (4.0% + 0.080 V) ± (2.0% + 0.060 V) ± (7.0% + 0.080 V)
60.00 V ± (4.0% + 0.80 V)
± (2.0% + 0.60 V)
± (7.0% + 0.80 V)
600.0 V ± (4.0% + 8.0 V)
± (2.0% + 6.0 V)
± (7.0% + 8.0 V)
1000 V ± (4.0% + 80 V)
± (2.0% + 60 V)
± (7.0% + 80 V)
* Accuracy linearly decreases from a value of (2% + 60 digits) at 200 Hz
to (7% + 80 digits) at 400 Hz.
AC Voltage
Range
Accuracy at
50 Hz to 400 Hz
6.000 V ± (1.2% + 0.005 V)
60.00 V ± (1.2% + 0.05 V)
600.0 V ± (1.2% + 0.5 V)
1000 V ± (1.2% + 5 V)
DC Voltage
Range
Accuracy
6.000 V ± (0.5% + 0.005 V)
60.00 V ± (0.5% + 0.05 V)
600.0 V ± (0.5% + 0.5 V)
1000 V ± (0.5% + 5 V)
AC + DC Voltage
Range
Accuracy at DC,
50 Hz to 400 Hz
6.000 V ± (1.4% + 0.007 V)
60.00 V ± (1.4% + 0.07 V)
600.0 V ± (1.4% + 0.7 V)
1000 V ± (1.4% + 7 V)
Input Impedance: 10 MΩ, 50 pF nominal
VFD
SELECT