background image

Texmate, Inc. Tel. (760) 598-9899  •  www.texmate.com

Page 10

FL-B101Q-HZ_manual (d0059)

!

WARNINg

AC and DC power supply voltages are hazard-

ous. Make sure the power supply is isolated 

before connecting to the meter.

COM

1&3

NO3

SP3

NO

SP1/3

COM

SP1

NC

SP2

N1

SP1

NO

SP2/4

COM

SP2

NC

SP2

NO

LOCK

COMMON

DIM

NC1

SP3

COM

2&4

NC2

NO4

SP4

NO1

SP1

NO2

SP2

8 9 10 11 12 13 14 15

17 18 19 20 21

23 24

1-6

See Leopard Family Input

Signal Conditioning Moduls

Analog

Analog

Output –

AC

Neutral

AC 

Line

– DC

+ DC

or

This meter uses plug-in type screw terminal connectors 

for all input and output connections. The power supply 

connections  (pins  23  and  24)  have  a  unique  plug  and 

socket  outline  to  prevent  cross  connection.  The  main 

board uses standard right-angled connectors.
Replacement 2-, 3-, and 4-pin plug connectors are avail-

able.

Input Signal – Pins 1 to 6 

Pins 1 to 6 are reserved for the input signal conditioner. 

See the data sheet for the selected input signal conditioner. 

Pins 8 to 15 – Relay Output Pins

Pin 8    SP3 NO. Normally Open 4 Amp Form A.

Pin 9    SP1/3 COM. Common for SP1 and SP3.

Pin 10   SP1 NC. Normally Closed 9 Amp Form C.

Pin 11   SP1 NO. Normally Open 9 Amp Form C.

Pin 12   SP4 NO. Normally Open 4 Amp Form A.

Pin 13   SP2/4 COM. Common for SP3 and SP4.

Pin 14   SP2 NC. Normally Closed 9 Amp Form C.

Pin 15   SP2 NO. Normally Open 9 Amp Form C.

Pins 17 to 21 – Rear Panel Switches

 

Pin 17   ANALOg OuTPuT (+). mA (0 to 20 mA/4 to 20 mA)  

or V (0 to 10 V) output is header selectable.  

Pin 18  ANALOg OuTPuT (–).  mA (0 to 20 mA/4 to 

 

 

20 mA) or V (0 to 10 V) output is header selectable. 

Pin 19  Programming LOCk. By connecting the LOCK pin  

 

to the COMMON pin, the meter's programmed  

 

parameters can be viewed but not changed.

Pin 20  COMMON. To  activate the LOCK or DIM functions  

 

from the rear of the meter, the respective pins have  

 

to be connected to the COMMON pin. This pin is  

 

connected to the internal power supply ground.

Pin 21  DIM. By connecting the display dim (DIM) pin to 

 

the COMMON pin, the display brightness setting

 

is halved.

Pins 23 and 24 – AC/DC Power Input

Auto-sensing AC/DC power supply. For voltages between 

 

85-265 V AC / 95-300 V DC (PS1) or 15-48 V AC / 10-72 V 

DC (PS2).

Pin 23  AC Neutral / –DC. Neutral power supply line.

Pin 24  AC line / +DC. Live power supply line.

Controls and Indicators

Connector Pinouts

Controls and Indicators

Pin Descriptions

Note:  The sequence of setpoint outputs is 3-1-4-2, enabling delay on 

make (dom) and delay on break (dob) to be used with both Form “C” 

relays.

Connectors

Standard plug-in screw terminal blocks provided by the Manufacturer

WARNINg

AC and DC input signals and power 

supply voltages can be hazardous. 

Do Not connect live wires to termi-

nal blocks, and do not insert, remove or han-

dle terminal blocks with live wires connected.

!

Straight-thru
Screw Terminal Plug

Part Numbers:
93-PLUG2P-DS....2 pins
93-PLUG3P-DS....3 pins
93-PLUG4P-DS....4 pins

Pin Socket

Pin Socket

Pin Socket

Pin Socket

Right-angled
Screw Terminal Plug

Part Numbers:
93-PLUG2P-DR.....2 pins 
93-PLUG3P-DR.....3 pins
93-PLUG4P-DR.....4 pins

Input Power
Screw Terminal Plug

Part Number:
93-PLUG2P-DP

Straight-thru Input Power
Screw Terminal Plug

Part Number:
93-PLUG2P-SP

93-PLUG5P-DR....5 pins
93-PLUG6P-DR....6 pins

Содержание FL-B101Q-HZ

Страница 1: ...upply AC DC Auto sensing wide range supply PS1 std 85 265 VAC 50 400 Hz 95 300 VDC 4 2W PS2 15 48 VAC 50 400 Hz 10 72 VDC 4 2W Operating Temp 0 to 50 C Storage Temp 20 C to 70 C Relative Humidity 95 n...

Страница 2: ...there are no menu or sub menus to navigate the programming and setup is quick and Span Buttons Span Zero Buttons Zero Set Point Button SP1 SP2 SP3 SP4 Front Panel Buttons Zero Button The Zero Button s...

Страница 3: ...d Mode 3 Hysteresis Band between SP1 SP2 This mode enables the Hysteresis function In order for Hysteresis to function SP2 must be set to a value greater than SP1 and SP2 should be selected as High h...

Страница 4: ...and carefully lever the plastic catch up and tilt the Display Board assembly forward Then repeat this action with the bottom catches Step 5 Remove the entire Display Board assembly by sliding it out o...

Страница 5: ...SPAN but ton is pressed the input signal being applied must be more than 5 higher or lower than the previously memorized value of the input signal that was being applied when the other button was last...

Страница 6: ...20mA If now the scaling has to be changed to read zero to full scale for an input of 0 to 20mA only the low 4 mA end needs to be recalibrated The high 20 mA end of the scaling is left untouched and so...

Страница 7: ...d SP4 activate when input is lower than set point SP1 and SP3 activate when input is equal to or higher than set point SP2 activate when input is lower than set point SP1 SP3 and SP4 activate when inp...

Страница 8: ...color overrides the SP1 color STEP A ENTER COLOR SET MODE Hold down ALL four setpoint buttons SP1 SP2 SP3 and SP4 and apply power to the meter The meter will light up in the Color Set Mode Release all...

Страница 9: ...utton adjust the analog output as measured on the external multimeter to be the required value 20mA in this example When the HI button is pressed the UP or DOWN indicator LED shows the direction of ch...

Страница 10: ...0 to 20 mA 4 to 20 mA or V 0 to 10 V output is header selectable Pin 19 Programming LOCK By connecting the LOCK pin to the COMMON pin the meter s programmed parameters can be viewed but not changed P...

Страница 11: ...omponent Glossary SPAN Turn Clockwise to Increase Reading To the Right Rear SPAN Potentiometer Pot If provided the 15 turn SPAN pot is always on the right side as viewed from the rear of the meter Typ...

Страница 12: ...I series IO board The adapter snaps on the 36x144 mm 1 42 x5 69 case and enables single unit or stack mounting in an existing 6 edgewise pointer meter cut out 100 0 25 50 75 100 0 25 50 75 SP1 SP2 SP3...

Страница 13: ...6 Metal Surround Case includes screw mounting clips 25 OP MTLCLIP Screw Mounting Clips 2 pc to screw tighten slide brackets 8 OP N4 144X36 144x36mm clear lockable front cover NEMA 4X splash proof 30 O...

Отзывы: