Component Layout

MAIN BOARD

INPUT MODULE

Relay Activation Mode 

Select Header

Relay Activation Mode 

Select Header

 

Low Voltage

 

Hi Voltage

IF02: Line Frequency

SPAN

ZERO

Frequency to Voltage Conversion

80 to 300VAC

IF02  

Line Frequency, 50-500VAC, 199.9Hz

ZERO POT

SPAN POT

Input Module Component Glossary 

SPAN

Turn Clockwise to
Increase Reading

To the 
Right Rear

SPAN Potentiometer (Pot)

If provided, the 15 turn SPAN pot is always on the 

right side (as viewed from the rear of the meter). 

Typical  adjustment  is  20%  of  the  input  signal 

range.

ZERO

Turn Clockwise to
Increase Reading

To the 
Left Rear

15 Turn Potentiometer

 + 

100 Counts

 –

 100 Counts

0

+

ZERO Potentiometer (Pot)

If  provided,  the  ZERO  pot  is  always  to  the  left 

of the SPAN pot (as viewed from the rear of the 

meter). Typically it enables the input signal to be 

offset ±5% of full scale (-100 to +100 counts).

Содержание FL-B101Q-HZ

Страница 1: ...upply AC DC Auto sensing wide range supply PS1 std 85 265 VAC 50 400 Hz 95 300 VDC 4 2W PS2 15 48 VAC 50 400 Hz 10 72 VDC 4 2W Operating Temp 0 to 50 C Storage Temp 20 C to 70 C Relative Humidity 95 n...

Страница 2: ...there are no menu or sub menus to navigate the programming and setup is quick and Span Buttons Span Zero Buttons Zero Set Point Button SP1 SP2 SP3 SP4 Front Panel Buttons Zero Button The Zero Button s...

Страница 3: ...d Mode 3 Hysteresis Band between SP1 SP2 This mode enables the Hysteresis function In order for Hysteresis to function SP2 must be set to a value greater than SP1 and SP2 should be selected as High h...

Страница 4: ...and carefully lever the plastic catch up and tilt the Display Board assembly forward Then repeat this action with the bottom catches Step 5 Remove the entire Display Board assembly by sliding it out o...

Страница 5: ...SPAN but ton is pressed the input signal being applied must be more than 5 higher or lower than the previously memorized value of the input signal that was being applied when the other button was last...

Страница 6: ...20mA If now the scaling has to be changed to read zero to full scale for an input of 0 to 20mA only the low 4 mA end needs to be recalibrated The high 20 mA end of the scaling is left untouched and so...

Страница 7: ...d SP4 activate when input is lower than set point SP1 and SP3 activate when input is equal to or higher than set point SP2 activate when input is lower than set point SP1 SP3 and SP4 activate when inp...

Страница 8: ...color overrides the SP1 color STEP A ENTER COLOR SET MODE Hold down ALL four setpoint buttons SP1 SP2 SP3 and SP4 and apply power to the meter The meter will light up in the Color Set Mode Release all...

Страница 9: ...utton adjust the analog output as measured on the external multimeter to be the required value 20mA in this example When the HI button is pressed the UP or DOWN indicator LED shows the direction of ch...

Страница 10: ...0 to 20 mA 4 to 20 mA or V 0 to 10 V output is header selectable Pin 19 Programming LOCK By connecting the LOCK pin to the COMMON pin the meter s programmed parameters can be viewed but not changed P...

Страница 11: ...omponent Glossary SPAN Turn Clockwise to Increase Reading To the Right Rear SPAN Potentiometer Pot If provided the 15 turn SPAN pot is always on the right side as viewed from the rear of the meter Typ...

Страница 12: ...I series IO board The adapter snaps on the 36x144 mm 1 42 x5 69 case and enables single unit or stack mounting in an existing 6 edgewise pointer meter cut out 100 0 25 50 75 100 0 25 50 75 SP1 SP2 SP3...

Страница 13: ...6 Metal Surround Case includes screw mounting clips 25 OP MTLCLIP Screw Mounting Clips 2 pc to screw tighten slide brackets 8 OP N4 144X36 144x36mm clear lockable front cover NEMA 4X splash proof 30 O...

Отзывы: