DL-40JANUS-DCA/DCV manual (d0114)

Component Layout

MAIN BOARD

MAIN BOARD HI VOLTAGE

MAIN BOARD LOW VOLTAGE

4-20mA INPUT MODULE

0-10V INPUT MODULE

4 to 20mA Process Loop Measurement

Order  IP02, if you require the loop

excitation voltage to be supplied by the meter.

24V

External

Loop Supply

Common

ZERO

SPAN

   Offset 

   PROCESS 4/20 mA

0

+

_

Other devices can be

added to the loop.

Direction

Of

Current

   <Decrease   Zero  Increase > 

   <Decrease   Span  Increase > 

   R

ange 

   HI 

   LO 

OFF

ON

24V EX

C

Fully User Scalable

PIN 2
PIN 1

PIN 3

+

_

Exc. On/Off

Header

SPAN Pot

HI / LOW 

SPAN RANGE 

Header

ZERO Pot

ZERO ADJUST Header

SPAN ADJUST 

Header

ZERO OFFSET 

RANGE Header

<Decrease     Increase>

<Decrease     Increase>

Lo

Hi

OFF

ON

-

0

+

Input Range 

Header

Exc. On/Off

Header

Exc. On/Off

Header

Span Adj. 

Header

Span Adj. 

Header

Zero Offset 

Range Header

Span Pot

Span Pot

(ID05)

(ID01)

(IP01/IP02)

Zero Offset Pot

Input Range 

Header

ID01: DC Volts, 2/20/200V/Custom w/24V DC Exc

Custom

200V 20V

2V

ON

OFF

24V Exc

24V

Exc

  < Decrease  Span  Increase > 

SPAN

DC VOLTS

PIN 1

PIN 2

PIN 3

Custom

200V 20V

2V

ON

OFF

24V Exc

24V

Exc

  < Decrease  Span  Increase > 

SPAN
ZERO

DC VOLTS

PIN 1

PIN 2

PIN 3

ID05: DC Volts 2/20/200/Custom V DC with Offset

           and 24V Exc. 

0

+

_

Offset

Содержание DL-40JANUS-PROCESS

Страница 1: ...l Features Specifications Software Features Index LEOPARD FAMILY DL 40JANUS PROCESS Two scaling methods MANUAL no external sig nal source required and AUTO requied an exter nal signal source Optional...

Страница 2: ...ed by pressing and releasing the or buttons When there are more than two display selec tions they are shown in brackets below the first display and are also selectable by press ing and releasing the o...

Страница 3: ...MAL POINT AND BRIGHTNESS SELECTION See Page 6 Setpoint 3 SP3 Setpoint 4 SP4 Valley Offset Scale Factor Calibrate Analog Output Lo Calibrate Analog Output Hi X XXX XX XX XXX X XXXX XXXX 2 3 4 Decimal P...

Страница 4: ...out STEP B Select Between Calibration of Input or Output Note If the analog output option is not present Step B is skipped and the program goes directly from Step A to Step C 1 Press the or button to...

Страница 5: ...wo Point Analog Output Note If the analog output option is not present Step B is skipped and the program goes directly from Step A to Step C 1 Press the or button to select the display toggling from C...

Страница 6: ...ress the P and buttons at the same time Display toggles between CAL and oFF 2 Press the P button Display shows previous dP selection STEP E Set the Decimal Point 1 Using the and adjust the display to...

Страница 7: ...counts and does not include the deci mal point If you need the decimal value with decimal point you will need to read the register convert it to decimal read 40024 see below to determine decimal locat...

Страница 8: ...HYST2 Setpoint 2 Hysteresis setting 40019 0x0012 SINT16 R W 1999 9999 PRES3 Setpoint 3 setting 40020 0x0013 UINT16 R W 0 9999 HYST3 Setpoint 3 Hysteresis setting 40021 0x0014 SINT16 R W 1999 9999 PRE...

Страница 9: ...e SP2 Delay on Make doM Delay Time Setting STEP H Set the SP2 Delay on Break dob Delay Time Setting STEP I Set the Hysteresis Setting for Setpoint 2 1 Using the and buttons adjust the display to the d...

Страница 10: ...g with external signal OFF 17 16 19 19 18 MANUAL rescaling ON AUTO scaling OFF ON SP1 NO SP1 NO SP2 NO SP2 NO Pins 14 and 15 AC DC Power Input Auto sensing AC DC power supply For voltages between 85 2...

Страница 11: ...es with 4 Independent 400V 210mA DC only SSRs DL 40JANUS Series 29 28 27 25 26 24 23 22 Options Order Code OR32 4A 4A 4A 4A 4A 4A OR34 4A 4A 4A 4A 4A 4A SP4 SP3 SP2 SP1 SP1 SP2 SP3 SP4 Relay Modules w...

Страница 12: ...XC FullyUserScalable PIN 2 PIN 1 PIN 3 _ Exc On Off Header SPAN Pot HI LOW SPAN RANGE Header ZERO Pot ZERO ADJUST Header SPAN ADJUST Header ZERO OFFSET RANGE Header Decrease Increase Decrease Increase...

Страница 13: ...ar 15 Turn Potentiometer 100 Counts 100 Counts 0 ZERO Potentiometer Pot If provided the ZERO pot is always to the left of the SPAN pot as viewed from the rear of the meter Typically it enables the inp...

Страница 14: ...4 7mm 0 19 DIN Cutout Spacer 2mm 0 08 Connector Socket Prog SP1 SP1 SP2 SP4 SP3 SP5 SP6 Prog SP1 SP1 SP2 SP4 SP3 SP5 SP6 Prog SP1 SP1 SP2 SP4 SP3 SP5 SP6 When extra panel mounting tightness is requir...

Страница 15: ...case is made from fire retardant polycar bonate A metal surround case can be ordered to enhance the meter s fire retardant capabilities and also provide shielding against electromagnetic interference...

Страница 16: ...RELAY OUTPUT OPTIONS ACCESSORIES OA____ DL 40JANUS PROCESS Add to the basic model number the order code suffix for each standard option required The last suffix is to indicate how many different spec...

Отзывы: