Quick Start Guide
Premier Elite Series
10
INS222-10
Global Options
System Timers
Use
to select a timer
,
press
/
and then
-
to enter a value
,
/
to accept
00:
Exit Settle Time
13:
Pulse Period 3
26:
Confirmation Dly
01:
Global Bell Dly.
14:
Line Fault Delay
27:
Warning Delay
02:
Global Bell Dur.
15:
AC Off Delay
28:
Keypad Lock Time
03:
Double Knock Dly
16:
Batt Test Period
29:
Eng. Log Off Dly
04:
Beam Pair Time
17:
Batt Test Time
30:
Fire Bell Delay
05:
Activity Delay
18:
Soak Test Time
31:
Forced Entry Dly
06:
Abort Delay
19:
Service Interval
32:
Supervision Time
07:
Courtesy Time
20:
Test Call Every
33:
Poll IP Every
08:
Defer Arming By
21:
Min Random Time
34:
Confirmed PA Timer
09:
Auto Arm Delay
22:
Max Random Time
35:
Seismic Timer 1*
10:
Menu Time Out
23:
Door Strike Time
36:
Seismic Timer 2*
11:
Pulse Period 1
24:
Zone Response
37:
Seismic Timer 3*
12:
Pulse Period 2
25:
Keypad PA Delay
*
for future use
System Config.
Use
to select an option
,
/
to change the option
,
/
to move to next option.
00:
No Bell on Arm Fail
21:
Zone Shorted = Tamper
42:
Cable Cut Expander Tamper
01:
Bell is an SAB
22:
Remote Reset = Reset
43:
Soak Test Active Arm Indication
02:
Clock is 24Hr
23:
User Code Outputs Pulse
44:
Confirm Low fob battery on Arm
03:
Auto BST/GMT Time
Change
24:
Test Calls Timed
45:
Entry Stray Notification
04:
View Armed Areas
25:
Battery Test by Timer
46:
BS Entry Stray Notification
05:
Global Bell Time
26:
Bells on 1
St
Alarm
47:
No Confirm for Alarm Device
Tamper
06:
24Hr Omit Local
27:
Internal Sounders on 1
St
Alarm
48:
Two Stage Wireless Arming
07:
Remove Omits
28:
Confirmation on Arm
49:
Stage Two with Zone OR Keypad
08:
Override Communicator
Delay
29:
Aborted Alarms = Engineer
Reset
50:
Confirmed Hold Up 2 Active PA
Zones
09:
NVM is Unlocked
30:
Auto AV Outputs
51:
Max Log Messages 3
10:
User + Engineer
31:
System Clock = 50Hz
52:
Code Entry Timed
11:
Chime Audible
32:
80 Column Printer
53:
PD6662:2010
12:
Allow Omitting of Tampers
33:
Disable Text
54:
Auxiliary Input = Tamper
13:
Enable Online Printing
34:
Enable EN50131-1
Requirements
55:
Part Arm Squawk
14:
Hide Activity Faults
35:
First Alarm after Entry Timeout =
Confirmed
56:
No Display Open Zones
15:
Hide Exit Errors
36:
Global Keypad Information
57:
Disable Battery Replacement
Mode
16:
Code Tampers Alarm
37:
EN50131-1 Grade 2 System
58
Remote Arming Instant
17:
Code Tampers Lockout
Keypad
38:
Disable Radio FOB PA
18:
Areas are displayed as A-H,
I-P
39:
Armed Mask = Fault
19:
Auto Select of Areas
40:
Radio FOB PA is Silent
20:
Enable Predictive Text
41:
Enable PSU Battery Monitoring
System Options
Use
to select a timer
,
press
/
and then
-
to enter a value
,
/
to accept
0:
Advisory Volume
4:
Multiple Knocks
8:
Language
1:
Chime Volume
5:
Adjust Clock
9:
Country Code & Defaults
2:
Number Of Re-Arms
6:
Quick Count
3:
Anti-code Resets
7:
Modem Level
Monitor
Hardware
Press
/
to edit
,
to select an option
,
/
to change the option
,
/
to accept
P
= Line Fault
B
= Bell Tamper
B
= Battery Faults
A
= AC Power Failure
A
= Aux Tamper
O
= O/Ps/Chgr
L
= Panel Lid Tamper
Control Timers
Use
to select an area
,
-
to enter the 1
st
On time
,
/
to accept
Use
-
to select the 1
st
On time days of operation
,
/
to accept
Use
-
to enter the 1
st
Off time
,
/
to accept
Use
-
to select the 1
st
Off time days of operation
,
/
to accept
System Text
Use
to select a message
,
-
to select characters
(predictive text is on by default but may be turned off as
described previously),
/
to accept
Part Arm Text
Use
to select a Part Arm
,
/
to edit the Part Arm text
,
-
to select characters
(predictive text is on
by default but may be turned off as described previously),
/
to accept